L2036H1 (031205c). Imaging No.: 031205c Sample: IDP (L2036H1) Beamline: BL47XU X-ray photon energy: 7 keV Exposure time for each projection: 1.5 sec.

Slides:



Advertisements
Similar presentations
IMAGE GENERATION IN CT.
Advertisements

Geometrical analysis of Young’s Double Slit Experiment:
Image Reconstruction.
Grey Level Enhancement Contrast stretching Linear mapping Non-linear mapping Efficient implementation of mapping algorithms Design of classes to support.
RAD 350 Chapter 17Digital Rad Tech. Spatial Resolution – ability to distinguish small items in close proximity with near the same atomic mass density Spatial.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Image reconstruction and analysis for X-ray computed microtomography Lucia Mancini 1, Francesco Montanari 2, Diego Dreossi 3 1 Elettra - Trieste 2 A.R.P.A.
Digital Imaging and Image Analysis
CT Physics V.G.Wimalasena Principal School of radiography.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Imaging Part 1.
Surface Reconstruction from 3D Volume Data. Problem Definition Construct polyhedral surfaces from regularly-sampled 3D digital volumes.
CS248 Midterm Review. CS248 Midterm Mon, November 3, 7-9 pm, Gates B01 Mostly “short answer” questions – Keep your answers short and sweet! Covers lectures.
Statistics.
Original image: 512 pixels by 512 pixels. Probe is the size of 1 pixel. Picture is sampled at every pixel ( samples taken)
Optical Density and Brightness
tomos = slice, graphein = to write
Planar X-ray Imaging Measure the integeral of the linear attenuation coefficient over the beam path through the object. has two main contributions 1.Photoelectric.
Lean Body Mass Assessment: Interpretations of Computed Tomography
Can people meet from 2:40 to 3:30 on Tuesday, September 5?
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
COMPUTED TOMOGRAPHY (I) RAD 365 CT - Scan
Digital Image Characteristic
Dott. Dario Tresoldi CNR IPCF ME
THREE-DIMENSIONAL SHAPES OF COSMIC SPHERULES AND CHONDRULES: COMPARISON FOR CHONDRULE FORMATION PROCESS. A. Tsuchiyama 1, T. Yada 2, and T. Noguchi 3,
Mineral grains from Ivuna ( ) Short summary 4 samples removed from the Ivuna meteorite were imaged at beamline BL47XU of SPring-8 on June 16,
Computed Tomography Physics, Instrumentation, and Imaging
1 Preview At least two views are required to access the depth of a scene point and in turn to reconstruct scene structure Multiple views can be obtained.
L2036H1 (031205c). Imaging No.: c Sample: IDP (L2036H1) Beamline: BL47XU X-ray photon energy: 7 keV Exposure time for each projection: 1.5 sec.
Medical Image Analysis Image Enhancement Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
The Digital Image Dr. John Ryan.
Seeram Chapter #3: Digital Imaging
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods Introductory Topics Part 2.
Nuclear Instrumentation Laboratory Federal University of Rio de Janeiro -BRAZIL X-ray Fluorescence and X-ray Transmission Microtomography Imaging System.
PRINCIPLE AND BASIC PHYSICS OF COMPUTED TOMOGRAPHY
September 5, 2013Computer Vision Lecture 2: Digital Images 1 Computer Vision A simple two-stage model of computer vision: Image processing Scene analysis.
Factors affecting CT image RAD
3. Image Sampling & Quantisation 3.1 Basic Concepts To create a digital image, we need to convert continuous sensed data into digital form. This involves.
Digital Imaging. Digital image - definition Image = “a two-dimensional function, f(x,y), where x and y are spatial coordinates, and the amplitude of f.
1 EFFECTS OF MOLECULAR ORIENTATION AND ANNEALING ON OPTICAL ABSORBTION OF ORIENTED PET POLYMER By Montaser Daraghmeh.
D. E. McKenzie (Montana State University), S. Gburek (Space Research Centre, Polish Academy of Sciences), L. W. Acton, P. C. Martens (Montana State University)
High resolution X-ray analysis of a proximal human femur with synchrotron radiation and an innovative linear detector M.Bettuzzi, R. Brancaccio, F.Casali,
Lecture 7: Intro to Computer Graphics. Remember…… DIGITAL - Digital means discrete. DIGITAL - Digital means discrete. Digital representation is comprised.
Digital imaging By : Alanoud Al Saleh. History: It started in 1960 by the National Aeronautics and Space Administration (NASA). The technology of digital.
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Digital imaging By : Alanoud Al Saleh. History: It started in 1960 by the National Aeronautics and Space Administration (NASA). The technology of digital.
More digital reading explaining LUT RT 244 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of.
Image Display. But first a review Remember the 3 main steps 1. Data Acquisition 2. Image Reconstruction 3. Image Display.
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
CT Chapter 4: Principles of Computed Tomography. Radiography vs. CT Both based on differential attenuation of x-rays passing through body Radiography.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
ISAN-DSP GROUP Digital Image Fundamentals ISAN-DSP GROUP What is Digital Image Processing ? Processing of a multidimensional pictures by a digital computer.
More digital 244 wk 12 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of Medicine Atlanta, GA,
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
Theory of Reconstruction Schematic Representation o f the Scanning Geometry of a CT System What are inside the gantry?
Chapter 6: Random Errors in Chemical Analysis. 6A The nature of random errors Random, or indeterminate, errors can never be totally eliminated and are.
Date of download: 7/11/2016 Copyright © 2016 SPIE. All rights reserved. Scheme of the simulation arrangement. The red hour glass shape denotes the illumination.
Unit: Properties of Matter
Digital Image Fundamentals
Mathematics for Computed Tomography
Medical Image Analysis
-42 Impact of signal non-repeatability on spectral CT images
Binary Notation and Intro to Computer Graphics
Modern imaging techniques in biology
Novel optical imaging technique to determine the 3-D orientation of collagen fibers in cartilage: variable-incidence angle polarization-sensitive optical.
Toshiro Oda, Keiichi Namba, Yuichiro Maéda  Biophysical Journal 
Basic Principles of CT Chapter 1.
Unit 1 Transformations in the Coordinate Plane
Unit 1 Transformations in the Coordinate Plane
Computed Tomography (C.T)
Presentation transcript:

L2036H1 (031205c)

Imaging No.: c Sample: IDP (L2036H1) Beamline: BL47XU X-ray photon energy: 7 keV Exposure time for each projection: 1.5 sec. No. of pixels for each projection image: 256 × 140pels No. of projection images for dark current : 2 (1 each before and after sample imaging) No. of projection images for incident beam current (I 0 ): 151 (+1; for determining the rotation axis) No. of projection images for transmitted beam current (I): 750 (+1; ditto) Imaging sequence: One I 0 imaging after every 5 I imaging Pixel size of projection images: 0.5 micron Voxel size of reconstructed CT images : 0.5 micron No. of voxels : 256 × 256 × 140 Location of sample rotation axis: ( z = ) Byte images: PV=0:CT value = 0 1/cm PV=400:CT value = /cm (theoretical LAC of enstatite) Cut images:Threshold: PV=22 Erosion: 3 layers Dilation: 6 layers Voxel size : 0.5 micron Number of voxels : 68 × 71 × 93 TLI3 images:Interpolation: 3 ×3 ×3 Voxel size : micron Number of voxels : 204 × 213 × 278 cut/33.tif (width: 34 m m)TLI3/99.tif (width: 34 m m)

L2036H1 (031205c) : browse image

L2036H1 (031205c) : external shape +X +Y -Z image +Y -Z +X image +X -Z+Y image -Z +X +Y

L2036H1 (031205c) : frequency diagram and phases LAC of troilite: cm -1 Estimated CT: cm -1 LAC of forsterite: cm -1 Estimated CT: cm -1 LAC of enstatite: cm -1 Estimated CT: cm -1 LAC of serpentine: cm -1 Estimated CT: cm -1 CT value = (651) * LAC TLI3/99.tif Minerals White (CTv >85 cm -1 ):iron sulfide?? Gray (CTv = 70.5 cm -1 :glass fiber Dark gray (CTv = 48.3 cm -1 ):hydrous silicate?? Black:void, air CT values are low compared with LAC of silicates and troilite. glueglass hydrous silicate? Fe sulfide?

L2036H1 (031205c): XRD (T.Nakamura et al.)

Glossary Beamline Three beamlines (BL20B2, BL20XU and BL47XU) are now available at Spring-8 for X-ray microtomography. We can choose the beamline mainly depending on the sample size and the spatial resolution. Browse image Some of a successive CT images of a sample can be seen at a glance by this image. Size scale (cm) and gray scale for CT values (cm -1 ) are shown in the right and left bottoms of the image, respectively. Byte image An monochromatic image where the brightness of each pixel is expressed by 8 bit ( steps). A series of byte images of an sample stored in the directory named “byte” are formed from original CT images by conversion from CT value to PV (usualy the theoretical LAC of a standard mineral is used for this conversion). CT value This is the value of LAC in each pixel of an CT image. In other words, an CT image is expressed as spatial distribution of CT values. CT values are calculated by CT reconstruction. If we use a monochromatic X-ray beam, CT value is ideally equal to the LAC of a material. However, they are not identical with each other in practice. Their empirical relations were determined at BL20B2 and BL47XU of Spring-8 (see np.29 for the relation at BL47XU). From this relation, we can estimate materials from CT values. Cut image This is a CT image, where unnecessary regions without sample are trimmed. A series of cut images of an sample stored in the directory named “cut” are formed from “byte” images by image processing using threshold for a sample and erosion and dilation procedures. Imaging No. Imaging number shows the date of imaging and its order. For example, c shows the third experiment (in alphabetical order) on 4 December, LAC (Linear attenuation coefficient) (of X-ray) A characteristic properties for X-ray attenuation of a material. This is a function of the bulk density, the chemical composition and X-ray photon energy.. Pixel One of many from which a 2-D image is composed. The shape is usually square. Projection image CT images are reconstructed from a series of projection images by rotating a sample by180 degrees. The size of a projection image gives the size of a CT image. For example, projection images of 512 × 220 pixels give 220 CT images of 512 × 512 pixels. Projection image for dark current A projection image without X-ray beam (dark image). This gives back ground of the projection images. Usually, 1 (or 2) dark image(s) is (are) taken before and after sample imaging experiment and their average is used for CT reconstruction calculation. Projection images for incident beam current (I 0 ) A projection image of X-ray beam without sample (I 0 image). This is taken at regular intervals of sample imaging (ussually 5 or 10 intervals).

Coordination system Projection images for transmitted beam current (I) A projection image of sample (I image). The projection, p=ln(I 0 /I), is calculated and used for CT reconstruction. Sample rotation axis The location of a sample rotation axis is required for CT reconstruction. This is called “center value”, which is generally described as a function of the height of a projection image (z: see the coordinate system). For example, the center value is expressed as follows: × z ± ( z = ). PV (Pixel value) This is the value that expresses the brightness of each pixel of a digital image. For example, the pixel is black and white for PV=0 and 255, respectively, in a byte image. Voxel One of many from which a 3-D image is composed. The shape is usually cubic. +X +Y +Z (0,0,0)

The relation between CT values and LAC determined by imaging standard materials at BL47XU (Nakamura et al., 2003)