Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.

Slides:



Advertisements
Similar presentations
Comparison of Visual Outcomes With Toric IOL and With Limbal Relaxing Incisions in Cataract Surgery Eriko Fukuyama, MD Fukuyama Eye Clinic Fukuoka, Japan.
Advertisements

Diffractive Multifocal IOL Prof. Dr. Daniel H. Scorsetti
Comparison of surgically induced astigmatism after phacoemulsification trough 3.2, 2.2 and 1.8 clear corneal incision. Luis Izquierdo Jr MD. PhD. Maria.
A simple and accurate method of alignment for toric intraocular lens implantation using anterior segment optical coherence tomography (OCT). Kazuno Negishi,
Keiichiro Minami, Hiroko Bissen-Miyajima, Mami Yoshino, Kunihiko Nakamura Department of Ophthalmology Tokyo Dental College Suidobashi Hospital, Tokyo,
In-the-Bag Toric IOL for Correction of Astigmatism in Keratoconus and after Corneal Surgery Bart T.H. van Dooren, M.D., Ph.D Ilse E.M.A. Mol, M.D. Department.
PIGGYBACK LENS AFTER MULTIFOCAL IOL IMPLANTATION Eric C. Amesbury MD Kevin M. Miller MD The authors have no financial interest.
Visual outcome & subjective visual symptoms of the Tecnis ZM900 multifocal intraocular lens in Asian eyes Dr Colin S.H. Tan MBBS, MMed (Ophth), FRCSEd.
NEW TRULIGN™ TORIC IOL Surgeon Training
Anupama Kotha 1, Simar J. Singh 1, William B. Trattler 1,2, Carlos Buznego 1,2 The authors have no financial interest in the subject matter of this poster.
A Prospective, Randomized, Comparative Evaluation of Patients with Contralateral Implantation of Two Aspheric Acrylic Intraocular Lenses R. Cionni, MD.
Eltutar, Kadir; Akcetin, Tulay A.; Ozcelik, N. Demet Istanbul Education and Research Hospital Department of Ophthalmology The authors state that they have.
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Disclosure of finanacial interest * Author has no financial interest in this paper. ** Author's research is partially funded by Imperial Medical Technologies.
Multifocal and Toric IOLs: An Update on the Resident Experience M. Allison Roensch, MD, Preston H. Blomquist, MD, Nalini K Aggarwal, MD, Justin W. Charton,
Progressive Multifocal Intraocular Lens G. Rubiolini M.D. Italy Disclosure of finanacial interest Author's research is partially funded.
1 Clinical Performance of the Crystalens® AO Guy M. Kezirian, MD, FACS.
Retrospective Comparison of 3177 Eyes Implanted with Presbyopic IOLs Carlos Buznego MD Elizabeth A. Davis MD, FACS Guy M. Kezirian MD, FACS William B.
M. Allison Roensch, MD, Preston H. Blomquist, MD, Nalini K Aggarwal, MD, James P. McCulley, MD Department of Ophthalmology University of Texas Southwestern.
Justin Charton, MD, Preston H. Blomquist, MD, Nalini K. Aggarwal, MD, James P. McCulley, MD University of Texas Southwestern Department of Ophthalmology.
Functional Vision With Apodized Diffractive Aspheric Multifocal IOL With +3.0 D Add Jonathan M. Davidorf, MD Los Angeles, CA ASCRS Annual Symposium March,
Bret Fisher, MD The Eye Center of North Florida Panama City, FL
G. Jacob 1,2, C. Bouchard 2, S. Kancherla 1. Edward Hines, Jr. VA Hospital, Hines, IL, Department of Ophthalmology 1. Loyola University Medical Center,
1 Cataract Surgery Stephen G. Slade MD, FACS. 2 Financial Disclosure Alcon, AMO, B&L Consultant, Clarity, NuLens, RVO, Technolas 2 This presentation represents.
PIGGYBACK IMPLANTATION OF FOR HIGH HYPEROPIA 24 MONTHS FOLLOW UP JL. FEBBRARO I.VIELPEAU, F. KRIFA, S.BERBACHE, S. GANEM Department of Ophthalmology S.
Blended vision after bilateral monofocal cataract surgery: an evaluation of spectacle independence and vision related quality of life Allison Landes, MD.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Neeti Parikh, MD Fuxiang Zhang, MD Department of Ophthalmology Henry Ford Hospital A Comparison Of Patient Satisfaction With Modified Monovision Versus.
Occurrence of Retinal Detachment After Cataract Surgery Peter Jeppesen MD, PhD and Thomas K. Olsen, MD, DMSc Department of Ophthalmology Århus University.
INTRAOCULAR LENS POWER CALCULATION BY IMMERSION A-SCAN BIOMETRY VERSUS CONTACT A-SCAN BIOMETRY MEASUREMENTS BEFORE CATARACT SURGERY Burak Bilgin**, M.D.,
Astigmatism management with toric intraocular lenses in cataract patients Adriano Guarnieri 1-2, Luis W. Lu 3-4, Alfonso Arias- Puente INCIVI, Madrid,
Use of Multifocal IOLs in Patients with Age-Related Macular Degeneration Helga P. Sandoval, MD, MSCR 1 Reid B. Murphy, MD, 1 Luis E. Fernández de Castro,
P91: Clinical Performance of Phakic Angle-Supported Investigational IOL in Prospective Global Trials, ASCRS 2010, Boston P91: Clinical performance of phakic.
Sonia Yoo, MD 1 Fernanda Piccoli, MD 1 Artur Schmitt, MD 1 Takeshi Ide, MD 1 Tsontcho Ianchulev, MD 2 Authors have no financial interest in this subject.
Kaori Morii, M.D. Shinji Miura, M.D, Ph.D. Dept. of Ophthalmology, Asagiri Hospital, Hyogo, JPN We have no financial interest. This retrospective study.
Comparison of LASIK and Mitomycin-C Assisted LASEK for Correction of Refractive Errors After Cataract Surgery Dr. Nitin Balakrishnan, Crystal Vision Laser.
LONG TERM OUTCOMES OF RESTOR IOL IMPLANTATION Lori Dao, Orkun Muftuoglu, V. Vinod Mootha, Steven M. Verity, R. Wayne Bowman, H. Dwight Cavanagh, James.
Outcomes of Transscleral Sulcus Fixation of Intraocular Lenses through a 2.4-mm Incision with an Injector System: 1-Year Follow-Up Akiko Masai, MD, Tomoichiro.
Influence of IOL optic material on posterior capsule opacification and visual function Ken Hayashi, MD Hideyuki Hayashi, MD Hayashi Eye Hospital, Fukuoka,
Johns Hopkins Hospital
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
Comparison of 2 Models of Aspheric Diffractive Multifocal IOL
O.I.I. EC-3 Hydrophobic Acrylic Intraocular Lens: The European Experience Thierry Amzallag, M.D. Institut Ophtalmique Somain, France.
Investigation of Multifocal Toric IOLs to Compensate for Corneal Astigmatism and to Provide Near, Intermediate, and Distance Vision José L. Rincón, MD.
Hongseok Yang, M.D. Dae Hee Kim, M.D. Department of Ophthalmology, Ajou University School of medicine, Suwon, Korea The authors have no financial interest.
Preliminary Results after Cataract Surgery with the Aspheric Acrysof ReSTOR IOL to Correct Presbyopia Meeting of the ASCRS Chicago 8-10 February 2007 R.M.M.A.
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
9-Month Results after Implantation of a new accommodative IOL that works with one focus Mark Tomalla M.D.* Clinic for Refractive and Ophthalmic Surgery,
Dissatisfication After Multifocal Intraocular Lens Implantation in Taiwan Yu Wei Lin, MD (Presenting Author); Ching-Ju Hsieh; Lin-Chung Woung The authors.
Long-term results of Phakic Refractive Lens (PRL™) implantation in high myopic eyes. Ioannis G. Pallikaris 1, 2, MD, PhD, Maria I. Kalyvianaki 1, MD, PhD,
Vinohrady Teaching Hospital, Prague, Czech Republic Vinohrady Teaching Hospital, Prague, Czech Republic M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD,
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
OUR EXPERIENCE WITH PRELOADED IOL CT LUCIA 601P(Y)
FreeVis LASIK Zentrum Universitätsklinikum Mannheim
Postoperative Refraction and Patient Satisfaction after Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses Robert Cionni, MD Financial.
Hayashi Eye Hospital, Fukuoka, Japan
Wavefront Optimized Retreatment after Prior Wavefront
Effect of Axial Length Measurement Method on Refractive Outcomes of Cataract Surgery: Real World Comparison of Partial Coherence Interferometry and Immersion.
Eye clinic of the 3rd Faculty of Medicine, Prague, Czech Republic
Early Experience with Descemet’s Stripping Automated Endothelial Keratoplasty Combined with Phacoemulsification: Clinical and Refractive Outcome University.
MI60 INTRAOCULAR LENSES – OUR EXPERIENCE
Clinical results of the aphakia correction using iris-fixated anterior chamber intraocular lens (Artisan) Authors have no financial interest Luis Izquierdo.
Long Term Clinical Outcomes of Refractive Lens Exchange in Moderate     to High Hyperopia Frank Goes, BELGIUM Ascrs 2008.
Thomas Kohnen, MD Department of Ophthalmology
성모병원 안센터 CHANGES IN ASTIGMATISM RELATIVE TO IOL HAPTIC INSERTION AXIS IN WITH-THE-RULE AND AGAINST-THE-RULE ASTIGMATISM PATIENTS Hyun Seung Kim, M.D.
Kellan Tetraflex KH3500 Accommodative IOLs vs. Acri
The authors have no financial interest
Visual Outcomes and Satisfaction with Toric IOL Versus Monofocal IOL
Comparative Global Literature Review of Visual and Optical Quality of Refractive, Diffractive, and Hybrid IOL Designs James P. McCulley, MD Department.
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo Vaz, MD Leonardo Akaishi, MD Patrick F. Tzelikis, MD None of the authors has a financial or proprietary interest in any material or method mentioned.

Purpose To compare the postoperative outcome of piggyback implantation using the AcrySof ReStor lens with Tecnis ZM900 multifocal intraocular lenses (IOL).

Material / Methods This prospective comparative study included patients with age-related cataract, primary hyperopia or hyperopic astigmatism, a normal ophthalmologic examination besides senile cataract, and unsatisfactory correction with glasses. Information collected included uncorrected visual acuity (UCVA) for near and distance, best corrected visual acuity (BCVA), and spherical equivalent (SE) before and after the surgery. All patients were followed for 6 months

The three lenses used in this study were TECNIS® ZM900 multifocal IOL, AcrySof ReStor® and CLARIFLEX®. The multifocal IOL (Tecnis ZM900 or AcrySof ReStor) was first implanted in the capsular bag and the Clariflex® lens was implanted second in the ciliary sulcus. Material / Methods

The TECNIS® multifocal IOL (Model ZM900, AMO, Santa Ana, CA) is a 3-piece diffractive multifocal lens with 6.00 mm polysiloxane optic. The AcrySof ® ReSTOR ® (Model SA60D3, Alcon Surgical Laboratories, Dallas, Texas) is an acrylic foldable single- piece IOL. The CLARIFLEX® (Model AMO, Advanced Medical Optics, Santa Ana, California) is 3-piece monofocal lens with 6.00 mm biconvex square-edged silicone optic and 10-degree angulated C polymethyl-methacrylate (PMMA) haptics. Material / Methods

The Holladay formula was used to calculate the IOL power when there was a short axial length (< 22.0 mm) and the SRK/T formula was used when there was an average axial length (≥ 22.0 mm). The A- constant used was for the TECNIS multifocal IOL, for the AcrySof ReStor and for the CLARIFLEX IOL. Axial length was measured with the IOL Master (Carl Zeiss Meditec AG), and the targeted postoperative refractive error was 0.0 Material / Methods

Preoperative Tecnis ZM900 (n=20 eyes) ReStor (n=21 eyes) P value Axial length mm (SD:±0.80)21.68 mm (SD:±0.39) P<0,001 Power IOL (D) D (SD: ±1.95)22.0 D (SD: ±1.75)P<0.001 UCVA0.08 (20/250) (SD: ±0.11) 0.25 (20/80) (SD: ±0.06) P<0.001 BCVA0.67 (20/30) (SD: ±0.08) 0.9 (20/22) (SD: ±0.17) P=0.02 SE D (SD: ± 2.25) D (SD: ±1.55)P=0.002 Teste t Student (SPSS) Results

Postoperative (6 months) Tecnis ZM900 (n=20 eyes) ReStor (n=21 eyes) P value UCVA for distance 0.67 (20/30) (SD: ± 0.15) 0.86 (20/23) (SD: ± 0.16) P=0.002 UCVA for near 33 cm J1 P=0.14 BCVA for distance 0.90 (20/22) (SD: ± 0.10) 1.00 (20/20) (SD: ± 0.05) P=0.002 BCVA at 60 cm J4.5J5P=0.08 SE0.00 D (SD: ± 0.45) D (SD: ± 0.40) P=0.06 Teste t Student (SPSS) Results

After a follow-up of 6 months, halos were reported as severe by 8.3%, moderate by 33.3% and absent or mild by 58.4% of patients in the Tecnis group. In the ReStor group halos were reported as severe by 9.0%, moderate by 27.3% and absent or mild by 63.7%. No interlenticular opacification (ILO) or another postoperative complication related to piggyback lenses was observed in our series. Results

Conclusion Overall, the use of a multifocal IOL in a piggyback fashion appears to be a safe and efficient procedure and a good refractive solution. Implanting 2 piggyback IOLs was beneficial in eyes with short axial length. The AcrySof ReSTOR IOL gave better outcomes than the Tecnis multifocal IOL in UCVA and BCVA for distance, probably because in the Tecnis group the eyes had shorter axial length and required higher diopter lenses.