High Resolution Jet Calorimetry or Total Absorption Homogeneous Calorimeter for SiD Adam Para, Fermilab SiD Workshop, Boulder, CO September 18, 2008.

Slides:



Advertisements
Similar presentations
High Resolution Hadron Calorimetry with Dual Readout Adam Para, Fermilab Trends in Photon Detectors, Trieste, June 3, 2008.
Advertisements

LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
NLC – The Next Linear Collider Project Colorado Univ. - Boulder Calorimetry Cornell-ALCPG Calorimetry Detector Study Plans at Colorado Uriel Nauenberg.
PFA-Enhanced Dual Readout Crystal Calorimetry Stephen Magill - ANL Hans Wenzel - FNAL Outline : Motivation Detector Parameters Use of a PFA in Dual Readout.
Particle interactions and detectors
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Simulation of the DHCAL Prototype Lei Xia Argonne National Laboratory American Linear Collider Workshop: Ithaca, NY, July , 2003 Fe absorber Glass.
1 Hadronic In-Situ Calibration of the ATLAS Detector N. Davidson The University of Melbourne.
Simulation of a Magnetised Scintillating Detector for the Neutrino Factory Malcolm Ellis & Alan Bross Fermilab International Scoping Study Meeting KEK,
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
LBNE R&D Briefing May 12, 2014 LBNE R&D Briefing May 12, 2014 LArIAT and LBNE Jim Stewart LArIAT EPAG Chair BNL LBNE LARIAT-EPAG J. Stewart BNL T. Junk.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
1 Jets and Jet-Jet Mass Reconstruction in a Crystal Calorimeter Adam Para, Hans Wenzel, Fermilab Nayeli Azucena Rodriguez Briones Universidad Autonoma.
Adam Para, Fermilab, April 26, Total Absorption Dual Readout Calorimetry R&D Fermilab, Caltech, University of Iowa, Argonne National Laboratory,
ALCPG October 25 th 2007 Hans Wenzel Calorimetry in slic How-to Motivation for dual readout Calorimeter What are our requirements Why did we choose SLIC.
Adam Para, November 29,2005 (Plan for/Thoughts on) Optimization the ILC detector for jet-jet mass resolution.
Development of Particle Flow Calorimetry José Repond Argonne National Laboratory DPF meeting, Providence, RI August 8 – 13, 2011.
Planar Dual Readout Calorimetry Studies Progress Report G. Mavromanoulakis, A. Para, N. Saoulidou, H. Wenzel, Shin-Shan Yu,Fermilab Tianchi Zhao, University.
Optimizing DHCAL single particle energy resolution Lei Xia Argonne National Laboratory 1 LCWS 2013, Tokyo, Japan November , 2013.
Implementing a dual readout calorimeter in SLIC and testing Geant4 Physics Hans Wenzel Fermilab Friday, 2 nd October 2009 ALCPG 2009.
Adam Para, Krzysztof Genser, Hans Wenzel,Fermilab ALCPG, Albuquerque September 30, 2009.
Optimizing DHCAL single particle energy resolution Lei Xia 1 CALICE Meeting LAPP, Annecy, France September 9 – 11, 2013.
The CALICE Si-W ECAL - physics prototype 2012/Apr/25 Tamaki Yoshioka (Kyushu University) Roman Poschl (LAL Orsay)
DHCAL - Resolution (S)DHCAL Meeting January 15, 2014 Lyon, France Burak Bilki, José Repond and Lei Xia Argonne National Laboratory.
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
CMS Calorimeter HB- HB+ HE- HE+ HF- HF+ HO-2 HO-1 HO0 HO+1 HO+2
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2/2) 3.Collider Experiments.
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 1 Paul Dauncey Imperial College London.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Pion Showers in Highly Granular Calorimeters Jaroslav Cvach on behalf of the CALICE Collaboration Institute of Physics of the ASCR, Na Slovance 2, CZ -
CALICE Digital Hadron Calorimeter: Calibration and Response to Pions and Positrons International Workshop on Future Linear Colliders LCWS 2013 November.
Development of a Particle Flow Algorithms (PFA) at Argonne Presented by Lei Xia ANL - HEP.
Bob Jacobsen July 24, 2001 From Raw Data to Physics From Raw Data to Physics: Reconstruction and Analysis Reconstruction: Particle ID How we try to tell.
Pandora calorimetry and leakage correction Peter Speckmayer 2010/09/011Peter Speckmayer, WG2 meeting.
Detector Monte-Carlo ● Goal: Develop software tools to: – Model detector performance – Study background issues – Calculate event rates – Determine feasibility.
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
18-23 July 2006J. Hauptman Vancouver LCW06 4th Calorimeter Plans (or dual readout is wonderful, but what are its problems) 1. Electrons and photons limited.
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
Calice Meeting Argonne Muon identification with the hadron calorimeter Nicola D’Ascenzo.
1 IWLC 2010 Geneva Oct.’10David Ward Tests of GEANT4 using the CALICE calorimeters David Ward  Electromagnetic particles (, e) were used to understand.
Calibration of the ZEUS calorimeter for hadrons and jets Alex Tapper Imperial College, London for the ZEUS Collaboration Workshop on Energy Calibration.
Adam Para, Fermilab, February 16, Who Cares? What is the Problem? 2 Dual Readout Total Absorption calorimeter has very good energy resolution.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Eunil Won/Korea U1 A study of configuration for silicon based Intermediate Trackers (IT) July Eunil Won Korea University.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
E. Auffrey, A.Benaglia, P. Lecoq, M. Lucchini, A.Para CALOR 2016, D AEGU, R EPUBLICK OF K OREA May 19, 2016 Also TICAL ERC Grant, P. Lecoq et al.
Adam Para, Fermilab Homogenous Hadron Calorimetry Workshop, Beijing, May 9, 2010.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
A Driutti, A Para, G. Pauletta, N. Rodriguez Briones & H. Wenzel
on behalf of ATLAS LAr Endcap Group
Where are we? What do we want to do next? Some thoughts
A Mulitplicity Jump B-tagger
Methods of Experimental Particle Physics
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Alternative CEPC Calorimeter
Experimental Particle Physics
Experimental Particle Physics
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Presentation transcript:

High Resolution Jet Calorimetry or Total Absorption Homogeneous Calorimeter for SiD Adam Para, Fermilab SiD Workshop, Boulder, CO September 18, 2008

SiD Detector Compact High resolution, robust tracking Good muon detection “Good enough” calorimetry Good enough??? How do we know what the ILC physics will be?? Even today: Chargino dM/M~(dE/E) jet. Reasonable cost-performance compromise ??? Maybe, but within some arbitrarily imposed set of constraints (like PFA). Why not a Super Hadron Calorimeter (SHC=PFA++), taking advantage of a compact (  relatively small volume) detector design. 2

Why Hadron Calorimeters are so Poor? Reminder: (dE/E) EM can be as good as 0.01 for total absorption calorimeters. What’s wrong with hadrons?: A fluctuating fraction of the hadron energy is lost to overcome nuclear binding energy Hadron calorimeters are sampling calorimeters – Sampling fluctuations (fluctuation of the energy sharing between passive and active materials) – Sampling fraction depend on the particle type and momentum (good example: a ‘neutrons problem’ in iron-scintillator calorimeter. SF ~ 0.02 at high energy, SF = 1 for thermal neutrons) Inhomogeneous calorimeters (typically: EM + HAD) The net result: Response/True energy = F(particle type, E). Tolerable for single particle measurement, major contribution to energy resolution for jets (collection of particles). 3

Path to High Resolution Jet Calorimeter Homogeneous Calorimeter (EM/Had combined). Need a calorimeter capable of performing required topological measurements for e/  (position, direction, close showers separation) Total absorption calorimeter (SF = 1 for all particles and energies). This practically implies a light- collection based calorimeter. Correct (on the shower-by-shower basis) for the nuclear binding energy loses. This can be done, for example, by dual readout of scintillation and Cherenkov light signals. 4

High Resolution Jet Calorimeter? All the underlying principles are known/understood since a very long time (> 20 years). If it is so simple why we haven’t built good hadron/jet calorimeters?? – Low density scintillators  huge detector size for total absorption – Bulky photodetectors  cracks to bring the light out or further increase of the detector size – No photodetectors in the magnetic field Major advances in the detectors technology/enabling technologies: – High density scintillating crystals/glasses ( ~20 cm) – ‘Silicon Photomultipliers’ ~ robust, inexpensive 5

Conceptual Design of a High Resolution Calorimeter Six layers of 5 x 5 x 5 cm 3 crystals (a.k.a. EM section): 108,000 crystals three embedded silicon pixel layers (e/  position, direction) 9 layers of 10 x 10 x 10 cm 3 crystals (a.k.a. hadronic section): 60,000 crystals 4(8?) photodetectors per crystal. Half of the photodectors are 5x5 mm and have a low pass edge optical filters (Cherenkov) – No visible dead space. – Signal routing avoiding projective cracks – Should not affect the energy resolution – 500,000(1,000,000?) photodetectors Total volume of crystals ~ m 3. 6

Separated Functions Calorimeter Calorimeters are expected to measure energies of particles/jets. But.. They are also expected to provide topological information: positions, directions, close showers separation. These additional requirements tend to complicate the detector design and compromise the energy measurement. A possible solution: decouple the energy and topological measurements. Delegate the topological measurements to two- three layers of silicon pads. Negligible fraction of shower energy deposited in silicon should have no adverse effect on the overall energy resolution. Such a concept has been put forward, and supported by INFN and DESY. Prototype has been constructed and tested in test beams at Frascatti and at CERN: LCCAL (P. Checchia, LCWS04) 3 layers of 0.9 x 0.9 cm silicon pads at 2, 6 and 12 X 0 7 e -  =2.16 mm  =2.45 mm 30 GeV electrons  =3.27 mm

LCCAL: Two Particle Separation Example 30 GeV e - Pad PH Tracked particle Ghost 2X 6X 0

Dual Readout Calorimeter Simulation and Analysis Optical calorimeter option in SLIC (Hans Wenzel) 1 x 1 x 3 m 3 volume subdivided into 1 cm 3 ‘crystals’ Crystals composed of various materials (elements or isotopes) at fixed density of 8 g/cm 3 Optical properties characterized by the refractive index n (relevant for Cherenkov) All scintillation (==ionization) and Cherenkov light summed up from the entire volume. Total information about an event reduced to two variables : S and C. Completely automatic reconstruction, no tuning/optimization. No use of the spatial distribution information (yet). Much room for the improvement. 9

Dual Readout at Work: an Example Physics model: QGSP_BERT Material: Fe56, n=1.65 (i.e. scintillating, transparent material with the absorption, radiation length and the nuclear properties of Fe56) 10 GeV negative pion beam Only ~80% of energy observed through ionization Cherenkov fluctuations much larger than the ionization Clear correlation of the total observed ionization and Cherenkov light Using the C-S correlation the energy resolution will be limited by the width of the scatter plot only 10

'Test beam' 100 GeV Step I: Electron Beam Calibration Collect the scintillation and Cherenkov light measured in some arbitrary units. Define the mean values of the distributions to correspond to 100 GeV (calibration beam energy) A sc =100/ A ch =100/ 11

'Test Beam' 100 GeV Step II:  - Beam Collect scintillation and Cherenkov light for 100 GeV negative pions entering the detector Use absolute calibration determined with electrons E sc = A sc *S E ch = A ch *C Notice (just observations, not used in the forthcoming): (  /e) sc ≈ 0.9 (  /e) ch ≈ 0.75 Resolution much worse with Cherenkov 12

'Test Beam' 100 GeV Step III: Analysis Plot average S/E beam as a function of C/S Fit some correction function F(C/S) (for example polynomial) Re-analyze the data: – E = A sc *S/F(C/S) Observe: – Average corrected energy(red) ≈ Beam Energy (==  /e ≈ 1) – Significantly improved resolution – Analysis completely automated, no tuning or free parameters 13

Scintillation vs Cherenkov Correlation: Energy Dependence 14 Cherenkov response linear Relative amount of Cherenkov light increasing with E (more  o ’s) Scintillation vs. Cherenkov correlation improving with E Slope of the correlation similar, but level increasing with E

Response and Resolution, Single Hadrons 15 After correction: good linearity of the corrected response good energy resolution ~ 0.12/√E no sign of a constant term up to 100 GeV Gaussian response function

'Other particles' We can calibrate the response of the detector to pions and protons (perhaps). Jets contain also neutrons and kaons. At high energies antiprotons and antineutrons are significant. We do not have neutrons/Ko/antineutrons test beams. K’s and antiprotons are scarce too. We may not have good particle ID inside jets, hence pion calibration will be used as a default. How does it affect the energy measurement?? 16

Different Particles, Corrected Response (Using Pion-derived Correction) Proton/neutron response: -2%, ~OK K’s: +0.5 GeV OK! Pbar, nbar: +1.5 GeV almost OK Resolution ~5% at 10 GeV for all the particles Gaussian response functions for all particles 17

Jets! Use Pythia e+e-  light quarks to create collections of particles with the composition and energy distributions characteristic of QCD jets (beware of the radiative return above Z0 peak) Edit the StdHEP list to send all jet particles along z-axis into the detector: S and C are the total amount of light collected from the jet Denote E jet = √s Use (for example) 10 GeV ‘pion test beam’ correction function to correct (as a function of C/S) the scintillation signal This is a very crude algorithm. In a real detector the correction can be applied to localized clusters, using a ‘local’ C/S. Many other improvements come to mind too.. Will investigate once the complete detector simulation is available. 18

Jets Response and Resolution, Raw Response is somewhat non-linear. Jet energy underestimated by ~10-20%. Can be calibrated using the data (W/Z), probably Constant term ~3.5% in energy resolution 19

Jets, Corrected Response Small non-linearity (~5%) for jets above 50 GeV Resolution improves like 1/√E (or better)  E/E ~ 0.22/√E Gaussian response function. No tails! 20

Jets, Summary Complete detector simulation Complete reconstruction (crude, far from optimal) Gaussian response function, no tails Energy resolution ( )/√E No indication of a constant term in the energy resolution up to 200 GeV Several improvements expected, once a complete detector simulation available This is only Monte Carlo simulation! How trust- worthy is it?? 21

Compare Different Monte Carlo Models Use two different physics lists: LCPhys and QGSP_BERT Most of the interactions with matter is the same, only hadron production modeling is different Surprisingly large difference between the overall response But.. Reconstruction/analysis does not use any input from the Monte Carlo,it derives everything from the test beam data (self-consistent set) Hence.. Treat one and the other simulated data set as a putative data and proceed with the calibration and reconstruction 22

Model Dependence of the Calorimeter Performance Use 10 GeV data sets simulated with two different GEANT4 Physics lists Treat each set as a hypothetical ‘data’. Derive self-consistent calibrations and corrections Correct the observed scintillation signal using the Cherenkov signal Overall response is stable to about ~1% Resolution vary by ~20% of itself (0.50 – GeV, or ( )/√E) 23

SiD Geometry, 100 GeV Single Pions: Look for Punch Through/Leakage 24 Low(er) energy tail == late showers escaping the calorimeter Muon system == tail catcher (Anti-)Correlation of the calorimetric energy and energy observed in a muon system

On-going Studies Dependence on the nuclear modeling (use different A absorbers) Performance (response and resolution) as a function of the thickness of the calorimeter (containment) Performance as a function of the integration time Importance/requirements for cross-calibration Light collection/separation SiPM’s characterization as possible photodetectors Fluctuations of light yield (especially Cherenkov) contribution Di-jet mass resolution: Calorimeter granularity Magnetic field contribution ……… H. Wenzel, D. Crowe (Fermilab), S. Cole, J. Hill (NIU), Tianchi Zhao, Washington, A. Driutti, G. Pauletta (Udine) 25

Reality Check? It is very likely that the simulation studies will continue to show that a total absorption calorimeter with dual readout can provide a high resolution jet calorimeter. They will never prove that you can built one, though. Practical issues: – Separation of Cherenkov and scintillation light (time and wavelength)  new crystals design (not too bright, slow scintillation, low cut-off for short wavelength light) – Affordable, mass produced crystals (industry) – Robust, affordable photodetectors – Engineering design of a hermetic, yet buildable and self- supporting detector 26

'Crystals' Q&A Are there crystals suitable for scintillation/Cherenkov light separation? No. Nobody asked for slow, dim scintillator, short absorption length. Can such crystals be designed/produced? Yes. (Alain Iltis, St. Gobain) Can such crystals be affordable (target price ~ $1/cc)? Probably. What drives the cost of crystals? – Energy cost for melting (  melting temperature) – Crucibles material wear – Raw materials (BGO) Do we need to insist on single crystals?? NO! High density polycrystalline scintillating materials have been produced. Cost can be greatly reduced. 27

Performance Risk ? Dual readout offers path to very good energy resolution. What happens if there is heretofore unknown flaw, or if the separation of Cherenkov/scintillation light will not be practically possible or affordable? Jet energy resolution of a total absorption calorimeter with scintillation only readout is ~ 3.5%. If this is deemed ‘good enough’ than a much cheaper calorimeter can be also contemplated using heavy scintillating glasses. (R&D program initiated at Ningbo University ) 28

Conclusion Very high resolution jest calorimeters with the energy resolution of the order of 20%/sqrt(E) appears quite feasible and attractive option for a relatively compact detector, like SiD. Such a calorimeter requires development of new scintillating materials. They appear to be quite feasible and may be quite affordable. Development of these new materials may take several years, but it is probably well matched with any realistic timeline for the ILC experiments. A scintillation-only total absorption calorimeter is an intriguing opition too. It is inferior to the dual readout one, but it may be an attractive cost-performance compromise. 29