Structure Gas Monitoring Requirements in 27 CCR Glenn K. Young, P.E. Senior Waste Management Engineer Closed Illegal & Abandoned Sites.

Slides:



Advertisements
Similar presentations
METAL COIL SURFACE MACT COMPLIANCE ASSURANCE 40 CFR PART 63, SUBPART SSSS May 2006 May 2006.
Advertisements

[Organisation’s Title] Environmental Management System
Claremore Medical Office Building From Landfill to Medical Office Building A Brownfield Success Story THE GREEN SIDE OF BROWNFIELD REMEDIATION.
Building on a Landfill Celeste Manolas, Project Manager Santa Barbara County General Services Capital Projects.
Landfill Buffer Zone Ordinance in Monterey County CIWMB/LEA Partnership Conference October 18, 2007 Matt Fore, REHS, MPA Monterey County LEA.
Water and Wastewater Focus Wireless Sales Push 2009.
Brownfield / Landfill Applications
California Integrated Waste Management Board 1 Agenda Item 5 (Committee Item F) September 8, 2008 Agenda Item 5 (Committee Item F) September 8, 2008 Consideration.
Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Wolfgang Garche Saxony-Anhalt.
California Integrated Waste Management Board Agreement with Air Resources Board for Surveillance Assistance Special Waste Committee Meeting May 10, 2006.
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
Air Quality Division Tank Degassing and Cleaning Rules; TSH :May 15, 2008 Page 1 Changes to Tank Degassing and Cleaning Rules Texas Association of Environmental.
Lindy Hughes Fleet Fire Protection Program Engineer Southern Nuclear Operating Company June 4, 2013 Fire Protection.
Laboratory Accumulation of Hazardous Waste Presented By: Richard Smith Environmental Health & Safety Administrative Office Research and Extension Centers.
Office of Engineering Safety1 How to Dispose of Chemical Waste from Engineering Facilities at Texas A&M University Hazardous Waste Disposal Training.
Developing a Chemical Risk Management Program
PERMIT REQUIRED CONFINED SPACES PERMIT REQUIRED CONFINED SPACES.
Environmental Considerations Confined Space Rescue is inherently dangerous and requires performance of rigorous activities under adverse conditions. Regional.
ISO Standard is based on the management model of plan – do - check – act. Today we all be discussing the elements of the standard that deal with.
BUILDING AND DEVELOPMENT CONTROL Willie Hannigan.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Newport Terrace Landfill (Continuous Gas Monitoring System)
Patrick Thornton, SNS/FPE June 9, 2008
WELCOME TO Gas Tester Training O2, LEL Monitoring
WORKER SAFETY Radionuclides Web Cast August 4, 2004 Loren W. Setlow Office of Radiation and Indoor Air
Manitoba Pork Council Loss Prevention Program Strategy A Detailed Explanation of the Loss Prevention Program Miles Beaudin, MBA, BSc.Ag., P.Ag.
Construction and Demolition Inert Processing Operations Compliance First: Evaluation of Solid Waste Facilities’ State Standards Training Provided By: California.
California Venue and Event Recycling Legislation Review of AB 2176 Model Ordinance For Waste Reduction at Venues and Events.
FRANKLIN engineering group, inc. Start-up Shutdown Malfunction Plan Development and Implementation Duncan F. Kimbro
Fort Ord, Monterey County, California History and Closure of a Landfill on a former Military Installation and Current Superfund Site Derek S. Lieberman,
Course Overview Day One Lecture Mod 1 – Mod 6 Practical – Orientation Air Systems Tending Systems Hazard Management Victim Packaging and Movement.
1 Assessment of Perimeter Landfill Gas Monitoring Probe Functionality Using a Video Borehole Monitor LEA/CIWMB Partnership Conference San Diego, CA – October.
Climate, Air Quality and Noise Graham Latonas Gartner Lee Limited RWDI Air Inc.
MRW Handling MRW = HHW + Conditionally Exempt Small Quantity Hazardous Waste Generators (CESQGs) Guidelines for facility development and permitting first.
The science that deals with the recognition, evaluation and control of hazards in workplaces in order to prevent illness among employees. ?
MINE GASES. Normal Air is made up of: Nitrogen 78% Oxygen 21% Trace Gases 1%
Solid Waste Association of North America City of Brandon’s “Presentation on Methane Gas Utilization” May 14, 2009 – Winnipeg.
Presumptive MACT For Municipal Solid Waste Landfills July 1999 Emission Standards Division US Environmental Protection Agency.
1 | Weatherization Assistance Program: The Federal Perspective (Part 1)eere.energy.gov NASCSP 2011 Mid-Winter Training Conference Weatherization Assistance.
Application – Identifying, Listing Equipment, and Documentation
ISO MONITORING AND MEASUREMENT. ISO Environmental Management Systems2 Lesson Learning Goals At the end of this lesson you should be.
Fires in Solid Waste Piles. Fires in Solid Waste Piles:
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
1 Permit Implementation Regulations Defines the phrase “significant change in the design or operation of a solid waste facility that is not authorized.
Ed Mussler, P.E., Permitting Branch Supervisor Solid Waste Section Division of Waste Management NC Department of Environment and Natural Resources Presentation.
California Integrated Waste Management Board 1 Committee Items C-D (Board Items 2-3) November 5, 2007 Consideration Of: Item C/2: The Scope Of Work For.
Program Overview and Update Program Overview and Update Successful Case Example: Belmont Shores Mobile Home Park, Los Angeles County LEA Successful Case.
1 Special Information Session on USEPA’s Carbon Rules & Clean Air Act Section 111 North Carolina Division of Air Quality Special Information Session on.
California Integrated Waste Management Board 1 Agenda Item 6 (Committee Item G) June 9, 2008 Agenda Item 6 (Committee Item G) June 9, 2008 Consideration.
NFPA 2 Overview Susan Bershad, Staff Liaison, NFPA.
Item 21 May 11-12, 2004 CIWMB Meeting Discussion And Request For Rulemaking Direction To Formally Notice Proposed Regulations For RCRA Subtitle D Program.
December 6, 2004CIWMB P&E Committee Workshop1 Postclosure Maintenance Postclosure Maintenance Beyond the Initial 30 Years and Financial Assurance Demonstrations.
California Integrated Waste Management Board Special Board Meeting CONSIDERATION OF BOARD ACTION OVER MADERA COUNTY LEA Sacramento, CA October 3, 2005.
1 LANDFILL GAS TRAINING. 2 INTRODUCTION  TYPE OF MONITORING -Screening -Specialized  GOALS.
Confined Space Rescue Level II Course Overview: Mod 1.
Confined Space Rescue Level I Technical References: Mod 3.
David K. Paylor Virginia State Board of Health March 17, 2016.
BY FRANS WILBRINK WILBRINK & ASSOCIATES. OUTLINE Classify the different types of hazardous areas Identify the risks associated with each of these areas.
IIPP An Overview of the Injury and Illness Prevention Program.
1 Emergency and Disaster Response to Chemical Releases Monitoring Module 4.
Results of the Review of MSW Landfill Regulations from Selected States and Countries Landfill Facility Compliance Study presented to California Integrated.
Atmospheric Monitoring. ATMOSPHERIC MONITORING INSTRUCTIONAL GOAL The participant will understand the need for atmospheric monitoring and the types, uses,
Pipeline Safety Management Systems
Designated substance requirements
Energy Storage System Guide for Compliance with Safety Codes and Standards Gene Eckhart November 2, 2016.
Steam Generation In any industrial process, large quantities of steam are consumed. If natural gas is used to heat the boiler water it is often advisable.
South Carolina Perspective on Part 61 Proposed Revisions
Municipal Solid Wastes (continued)
Cupa violation Review BAESG Meeting May 20, 2019 Matthew Burge
Risk Management NDS Forum June 23rd 2010.
Presentation transcript:

Structure Gas Monitoring Requirements in 27 CCR Glenn K. Young, P.E. Senior Waste Management Engineer Closed Illegal & Abandoned Sites

Structure Gas Monitoring Purpose Data Analysis Results

Structure Gas Monitoring

Structure Gas Monitoring Regulations in 27 CCR (a) (1) requires that “…The concentration of methane gas must not exceed 1.25% by volume in air within on-site structures…” 20931(a) “…monitoring network design shall include provisions for monitoring on site structures, including but not limited to buildings, subsurface vaults, utilities or other areas where potential gas buildup would be of concern…” 20931(c) “…Structures located on top the waste disposal area shall be monitored on a continuous basis..” (a)(1) “…monitoring reports shall include: (1) the concentrations of the methane….within each on-site structure…” (a)(3) “…the documentation of date, time, barometric pressure, atmospheric pressure, general weather conditions and probe pressures…”

Structure Gas Monitoring Data Analysis Time-trend continuous monitoring data for one year from 8 gas sensors placed throughout the park will be reviewed by the CIWMB/LEA to determine if 1.25% gas is exceeded in monitored coach skirts Important Note: Based on the results of the CIWMB Gas Investigation Report (Feb 2005), it is recommended that all coaches be required to be equipped with continuous gas monitoring systems (fixed combustible gas detection systems) since the integrity of the disposal site cap is unknown under each coach Applicable Regulation: Control (d) “…When the results of monitoring in on site structures indicate levels in excess of those specified in Section 20923(a), the operator shall take appropriate action to mitigate the effects of landfill gas accumulation in on site structures, and public health and safety, shall include one or more of the following:…(4) Alarms, …(5) Ignition source control…(7) Ventilation…”

Structure Gas Monitoring Results End State: The site will be judged to be in compliance with applicable regulations (27 CCR & 20937) when all coaches are continuously monitored for landfill gas and actions are taken to prevent the accumulation of gas in coaches where concentrations exceed 1.25% Vgas/Vair