RHIC CNI Polarimeter status RHIC CNI Group February 26, 2008.

Slides:



Advertisements
Similar presentations
AGS Status and Plans RHIC Spin Collaboration Meeting 2/4/11.
Advertisements

E.C. Aschenauer 2013/03/132 polarisation for Blue and Yellow t o -calibration underway minimal impact on polarization, makes A N more stable  should.
Beam direction and flux measured by MUMON K. Matsuoka (Kyoto) for the MUMON group Contents: 1.Beam stability (direction/flux) 2.Absolute  beam flux.
PHENIX local RUN9 RHIC meeting Manabu Togawa for the PHENIX 1.
APEX Report April 28-29, 2009 May 4, 2009 Fulvia Pilat Time Meeting, May
E.C. Aschenauer Phil Pile Meeting 2012/03/202 polarisation at injection Blue and Yellow Caveat: only first round of cleaning up noise in polarimeters.
AGS pp Status Feb. 6, 2015 RSC Meeting Haixin Huang.
Bunch-by-bunch (relative) polarization measurements using inner annuli of STAR BBC Andrew Gordon April 4, 2008.
RHIC Status Haixin Huang Time Meeting 02/1/2011. Jan. 26 Ring access for six hours to fix jet and many other jobs. Difficulty to provide 28X28 store overnight.
RHIC/AGS Polarimeter Study May 1, 2009 H. Huang, A. Zelesnki, B. Morozov.
Beam profile vs time Analyzed Vx vs Vy distributions vs time for –Run 72 (13:26:02 – 28:25) –Run 73 (13:36:10 – 13:37:30) –Run 74 (43:12 – 44:21) Binned.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 5 Apr 2011 Agenda: Open.
The polarized hydrogen jet target measurements at RHIC Andrei Poblaguev Brookhaven National Laboratory The RHIC/AGS Polarimetry Group: I. Alekseev, E.
AGS pp Status Feb. 20, 2015 RSC Meeting Haixin Huang.
DIS 2006 TSUKUBA April 21, 2006 Alessandro Bravar Spin Dependence in Polarized Elastic Scattering in the CNI Region A. Bravar, I. Alekseev, G. Bunce, S.
PHENIX Status, 2/22/11 VTX commissioning on beam Local polarimeter in service 9.6% in blue, -16.6% Residual transverse component for longitudinal beam.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
DIS 2006 Tsukuba, April 21, 2006 Alessandro Bravar Proton Polarimetry at RHIC Alekseev, A. Bravar, G. Bunce, S. Dhawan, R. Gill, W. Haeberli, H. Huang,
PHOS calibration in CDB framework M.Bogolyubsky, Y.Kharlov B.Polichtchouk, S.Sadovsky IHEP, Protvino ALICE off-line week 3 October 2005.
7/30/99Douglas E. Fields for the E950 Collaboration 1 A CNI Polarimeter for RHIC Spin Results from IUCF CE75 & AGS E950 M. Bai, G. Bunce*, H. Huang, Y.
E.C. Aschenauer RSC-Meeting, January 21st T h e b e s t k e p t s e c r e t n u m b e r a t R H I C / B N L / U S A f o r s u r e n o t t o b e.
Absolute polarimetry at RHIC Hiromi Okada (BNL) I. Alekseev, A. Bravar, G. Bunce, S. Dhawan, O. Eyser, R. Gill, W. Haeberli, O. Jinnouchi, A. Khodinov,
Run 8 Polarization measurements from STAR BBC Andrew Gordon September 12, 2008.
Preparation for RHIC PP Run in 2011 Wednesday 20, 2010 RHIC Machine Planning Meeting Haixin Huang RUN website: RUN.
Systematic Errors Studies in the RHIC/AGS Proton-Carbon CNI Polarimeters Andrei Poblaguev Brookhaven National Laboratory The RHIC/AGS Polarimetry Group:
Dima Svirida (ITEP/BNL) Comments on Polarimeter Programming NEW IN RUN6  AGS polarimeter switched to 10 times faster readout with CMC100 USB controller.
Polarized beam in RHIC in Run Polarimetry at RHIC A.Zelenski, BNL PSTP 2011, September 13, St.Petersburg.
October 14, 2004 Single Spin Asymmetries 1 Single Spin Asymmetries for charged pions. Overview  One physics slide  What is measured, kinematic variables.
K.O. Eyser --- Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region -1- Absolute Polarization Measurement at RHIC in the.
Relative Polarization Measurements of Proton Beams Using Thin Carbon Targets at RHIC Grant Webb Brookhaven National Laboratory Sept 14, 2015PSTP20151 for.
Polarization Measurements of RHIC-pp RUN05 Using CNI pC-Polarimeter Itaru Nakagawa (RIKEN/RBRC) On behalf of CNI Polarimeter Group I.G.Alekseev A A.Bravar.
Polarization Measurement of 100GeV Proton Beams at RHIC with CNI pC Polarimeter Itaru Nakagawa (RIKEN/RBRC) On behalf of CNI Polarimeter Group I.G.Alekseev.
» Absolute Polarimetry of Proton Beams at RHIC« Oleg Eyser for the RHIC Polarimetry Group International Workshop on Polarized Sources, Targets and Polarimetry.
UC Davis June st Rosi Reed Low Energy Test Run Results Rosi Reed University of California at Davis.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 12 Apr 2011 Agenda: Open.
Photon Flux Control Liping Gan UNCW. Outline PrimEx-  experiment requirement Tagged photon Procedure to obtain the number of tagged photons Relative.
» RHIC Polarimetry « Oleg Eyser for the RHIC Polarimetry Group 2014 RHIC Retreat, August 14.
Oct 6, 2008Amaresh Datta (UMass) 1 Double-Longitudinal Spin Asymmetry in Non-identified Charged Hadron Production at pp Collision at √s = 62.4 GeV at Amaresh.
Proton Polarimetry at RHIC K. Oleg Eyser for the CNI polarimeter group Newport News, VA, October 25, 2013.
RHIC Run11 Summary May 6, 2011 RSC Meeting Haixin Huang Luminosity Availability Polarization RHIC setup issues.
A. Zelenski a, G. Atoian a *, A. Bogdanov b, D.Raparia a, M.Runtso b, D. Steski a, V. Zajic a a Brookhaven National Laboratory, Upton, NY, 11973, USA b.
Run 12 RHIC Machine/Experiments Meeting 17 Apr 2012 Agenda: Status reports Polarization issues update (E. Aschenauer) Other business With 17 April update.
Run6 CNI Analysis: Concluding Remarks and Summary of Systematic Uncertainties A.Bazilevsky For RHIC CNI group RHIC Spin Collaboration Meeting November.
POLARIZATION MEASUREMENTS AND ABSOLUTE POLARIZATION VALUES EVOLUTION DURING PROTON BEAM ACCELERATION IN THE RHIC ACCELERATOR COMPLEX A.Zelenski, T.Roser,
Beam intensity profile measurements with the RHIC (AGS) C-CNI polarimeters. Polarization profile measurements. Polarimeter target mechanisms upgrades.
Jin Huang M.I.T. For Transversity Collaboration Meeting Jan 29, JLab.
Orbit related issues of the spin tune control at RHIC V.Ptitsyn, M.Bai, W.MacKay, T.Roser.
E.C. Aschenauer STAR Spin PWG 2012/03/222  Known complications:  100 GeV: o noise due to pickup especially at injection less significant at flat top.
versus Proton spin vector Double-spin helicity asymmetry: N ++ / L ++  N +  / L +  N ++ / L ++ + N +  / L +  1 P1P2P1P2P1P2P1P2 A LL  Single-spin.
Run 12 RHIC Machine/Experiments Meeting 24 Apr 2012 Agenda: Status reports Other business.
Update on the CNI polarimeter results for Run02 1.Bunch-by-bunch polarization study 2.Profiles of 0-pol bunches Osamu Jinnouchi.
P-Carbon CNI polarimeter upgrades. Vacuum system. Target drives. Targets. Polarimetry Workshop, July 31, 2009 A.Zelenski for polarimetry group.
Thomas Roser Snowmass 2001 June 30 - July 21, 2001 Proton Polarimetry Proton polarimeter reactions RHIC polarimeters.
Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region September 30, 2006 RHIC Spin Collaboration Meeting RIKEN, Wako, Japan.
1 Data taking & ONLINE analysis at MCR Hiromi Okada June, 2008.
RHIC Polarimetery A.Bazilevsky for RHIC Polarimetry group RHIC Spin Collaboration Metting April 10 (Friday), 2009.
RHIC pC polarimeter what has been achieved and what needs to be done Osamu Jinnouchi RBRC 2/10/05 RSC meeting.
RHIC Status April 8, 2011 RSC Meeting Haixin Huang.
E.C. Aschenauer RSC - Meeting 2012/03/232  Known complications:  100 GeV: o noise due to pickup especially at injection less significant at flat top.
RHIC pC Polarimeters in Run9: Performance and Issues A.Bazilevsky for the RHIC CNI Group Polarimetry Worshop BNL, July 31, 2009.
CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting.
H-jet Run at Injection A. Dion, H. Huang, A. Poblaguev, A. Zelenski, and YM.
APEX Status and Plan Phil’s Meeting, March 20, 2012 M. Bai.
RHIC pC Polarimeter status A.Bazilevsky For RHIC CNI Group February 26, 2008.
Polarized Proton Acceleration in the AGS with Two Helical Partial Snakes October 2, 2006 SPIN 2006 H. Huang, L.A. Ahrens, M. Bai, A. Bravar, K. Brown,
Kazuya Aoki For the PHENIX Collaborations. Kyoto Univ. / RIKEN
Today’s topics; New AN and ANN results at s = 6.9 GeV
Status of Instrumental Beam Studies and Technical Description of Detectors and DAQ February 24, 2017.
Run5 Analysis of RHIC-pC Polarimeter
p0 ALL analysis in PHENIX
Presentation transcript:

RHIC CNI Polarimeter status RHIC CNI Group February 26, 2008

 2 /ndf = 6.5/6 33 Hours, 10 stores, 1.4M events Statistics uncertainty only Rough event selection TOF width cut (+/- 10nsec) Channel 2-3 width selection No background correction. HJet: Blue1

Fill#H-Jet Events total P BLUE =0.486  0.023

 2 /ndf = 1.9/6 25 Hours, 3 stores, 1.4M events (Feb ) Statistics uncertainty only Rough event selection TOF width cut (+/- 10nsec) Channel 2-3 width selection No background correction. HJet: Blue2

Fill#Events    total  0.023

HJet: Yellow P YELLOW =0.384  Fill#H-Jet Events total168923

HJet: Yellow  2 /ndf = 9.8/6 31 Hours, 6 stores, 1.7M events Statistics uncertainty only Rough event selection TOF width cut (+/- 10nsec) Channel 2-3 width selection No background correction.

pC: Online Polarizations Only scan measurements at store Measures average polarization over trans. profile This is what directly (should) relate to HJet measurements, but… Absolute scale in not yet fixed A N from Run4! Latest fills not yet included

pC: averaging Mainly in blue: Intensity profile is flat  we stay longer at beam center than at periphery  measured polarization is closer to P max than to /P max ~ 0.93 for blue, see next slides Yellow looks fine for this Latest fills not yet included

Polarization Profile   P(L/L max ): just an example If there are problems with target position determination  Exclude position from calculations: R=0.29  0.07 Latest fills not yet included

Polarization Profile R vs fill ~ 0.28 /P max ~0.88 ~ 0.16: /P max ~ 0.93 Run5/6: R~ 0.10  0.15 Latest fills not yet included

pC vs Hjet HJet-yellow HJet-blue P online (pC)/P(Jet)=1.06  %: C energy correction and cuts (online/fast_offline difference) +7%: change in A N A N from Run4! P online (pC)/P(Jet)=1.17  %: from “bad” scans in this period (flat intensity profiles) +4%: C energy correction and cuts (online/fast_offline difference) +7%: change in A N A N (Run5)/ A N (Run4) ~ 1.01 A N (Run6)/ A N (Run4) ~ 1.15 Latest fills not yet included

Fast offline, normalized to HJet Normalization uncertainty (stat. only) Feb 23Feb 14 Latest fills not yet included

Summary HJet demonstrates very stable/consistent measurements Consistent target asymmetry vs -t (with the same target polarization) Same (and even lower in Run8) background level pC data Polarization profile in blue is similar to Run5/6; polarization profile in yellow is sharper Experiments see more polarization than HJet due to intensity squared weighting: by 7%-relative in blue and by 12%-relative in yellow (if vertical and horizontal profiles are the same!) Blue-online polarizations are overestimated by (17  6)%-relative +7% - from A N (compared to Run4) Yellow-online polarizations are overestimated by (6  6)%-relative +7% - from A N (compared to Run4)

Backups

Hjet: Background level 1.2 <T R <2.5 MeV, 2 hours data YELLOW mode BLUE mode BPM at IR12 reading: Blue (x,y)= (+5, +8)mm Yellow (x,y) = (0,  4)mm, Fill#9920 BPM at IR12 reading: Blue (x,y)= (0,  4)mm Yellow (x,y) = (  10, +10)mm, Fill#9905

pC: Online vs “fast offline” Yellow online polarizations look unbiased compared to online Blue online polarizations are overestimated compared to online by ~4% relative Absolute scale in not yet fixed

pC stability: “Dead Layer”

pC stability: T0