ASHRAE Tech. Paper, Long Beach, CA. June 26,2007 Poster Session Presentation: Poster contents. Jae-Weon Jeong, PhD Assistant Professor. Texas A&M University-Kingsville.

Slides:



Advertisements
Similar presentations
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
Advertisements

100% Outside Air and Dehumidification Management
TYPES OF MECHANICAL SYSTEMS
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Moisture to water converter. Out Line : Abstract Introduction Heat Pump Heat Pump Components Conclusion.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Heat Recovery for Commercial Buildings
Heating and Air Conditioning I
Introduction Enthalpy Wheel
Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering PSU, Univ. Park, PA Web: Chilled Surfaces:
1 Condensation Control Experiences in an “historic” Building with Movable Sash ASHRAE Anaheim Seminar 53, 1/28/04 Stanley A. Mumma, Ph.D., P.E. Professor,
MOLLIER DIAGRAM.
1 Decoupling the Building Latent and Sensible Loads Using 100% Outside Air Systems ASHRAE Chicago Seminar 39 January 24, 2006 Stanley A. Mumma, Ph.D.,
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Best Direction System Ltd.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Web Based BACnet Compatible Controls Applied to Emerging HVAC Technologies Stanley A. Mumma, Ph.D., P.E. Prof. Architectural Engineering Penn State University.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Kurt M. Shank, M.S. & Stanley A. Mumma, Ph.D., P.E. College of Engineering Department.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Objectives Discuss Project Topics Learn to design VAV and DOAS System.
ISAT Module V: Industrial Systems
1 Stanley A. Mumma, Ph.D., P.E. Professor Emeritus Penn State Univ. Park, PA Web: Active and Passive.
Conditioning of Moist Air
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
Direct Digital DBT, %RH, and Condensate Control for a DOAS-CRCP system ASHRAE Winter Meeting Symp. 3, Orlando-Feb. 6, 2005 Stanley A. Mumma, Ph.D., P.E.
Course project presentation Thursday in class Timing: 4 minutes (strictly controlled) Approximately 1 PowerPoint Slides per minute Content Problem Introduction.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
Objectives Discuss final project deliverables Control Terminology
2003 ASHRAE Annual Meeting Kansas City Energy Conservation Benefits of a DOAS with Parallel Sensible Cooling by Ceiling Radiant Panels Jae-Weon Jeong Stanley.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Energy Plus & Open Studio Class
Objectives Finish DOAS Control Terminology Types of controllers
Achieving Dry Outside Air in an Energy-Efficient Manner PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Stanley A. Mumma, Ph.D.,
Final Projects Grading criteria is posted on the course website Preliminary results are due Next Tuesday Final Project delivery on Monday Dec. 7 th –Final.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Objectives Ventilation analysis with HOP Human exposure/IAQ Ventilation and energy.
Reminder about the Filed Trip Tomorrow 8 am St. Edward's University We will meet at 8:00 am at the south entrance of the new Science building (visitor.
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
HCB 3-Chap 19B: All-Air_Multizone_Reddy1 Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES Agami Reddy (July 2016) 1)CAV terminal reheat 2)CAV multizone.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Announcements Next class is the course evaluation
Maria’s Restaurant Chapter 2 Section 9
Pros and Cons of operating a DOAS EW continuously
Doug Jefferson, Business Development Engineer
Grunenwald Science and Technology Building
Psychrometric Processes
Munters DOAS, Chilled Beams and VRV
Energy Efficiency in District Coiling System
Cheryl Hughes Regional Sales Manager October 6, 2015
HCB 3-Chap 19A: All-Air Systems_Single Zone
Variable Refrigerant Volume
Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES
Psychrometry & Air-conditioning
Lecture Objectives: Discuss Projects 1 and 2
Professor of Architectural Engineering College of Engineering
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Maria’s Restaurant Chapter 2 Section 9
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

ASHRAE Tech. Paper, Long Beach, CA. June 26,2007 Poster Session Presentation: Poster contents. Jae-Weon Jeong, PhD Assistant Professor. Texas A&M University-Kingsville Stanley A. Mumma, PhD, PE. Professor Emeritus Pennsylvania State University

The central focus of this paper is the operation and control of a total energy recovery device, or enthalpy wheel (EW), during the heating and intermediate seasons when the outside dew point temperature (DPT) is below the desired supply air DPT. For the most part, control of the EW during hot and humid conditions is being executed properly. On the other hand, experience has shown that the heating season operation is an important and frequently ignored aspect of the energy recovery operation. Consequently, the benefits which are available with proper EW control and operation during the “non-cooling” season have been overlooked. So there are no simple and universally accepted EW humidification performance control sequences currently in existence for low dew point temperature outdoor air conditions (i.e. dry outdoor air conditions). After providing an overview of EW fundamentals, a simple binary EW control is introduced and evaluated in a university campus facility for humidification under dry outdoor air conditions. It was found that use of an EW can reduce the energy consumption for humidification, but does not eliminate the potential need for an auxiliary humidifier. Finally, binary control of the EW for supply air temperature control is also addressed. Introduction

Enthalpy Wheel Humidification the following example is presented in an effort to provide an understanding of the performance, energy, and cost associated with using the EW for humidification in the dry condition. For the example, assume the following: Internally load dominated building with 100 people (standing), Latent load 250 Btu/hr-person (73.3 W/person). Building design latent load 25,000 Btu/hr (7.3 kW). 2,000 cfm (940 l/s) OA ventilation for the building. Room design condition 72°F (22°C) DBT, 30% RH. Hmidity ratio (w) of 35 gr/lbmDA (5.0 g/kgDA) and an enthalpy (h) of 22.7 Btu/lbmDA (35 kJ/kgDA). Consider a dry OA condition of 55°F (12.8°C) and 20% RH (W=12.8 gr/lbmDA (1.8 g/kgDA), h=15.2 Btu/lbmDA (17.4 kJ/kgDA)). Under these conditions, the latent load would cause the humidity ratio of the DOAS supply air to increase by 18.4 gr/lbmDA (2.6 g/kgDA) as it passed thru the space. Without humidification, the resulting room RH would be 26.7%. In order to get the humidity up to 30%, assuming an EW effectiveness of 80%, the EW would need to operate at a very slow modulating speed to achieve an effectiveness of only 17%, or operate at full speed 21% of the time.

Mass Balance in EW Humidification Fig. 1. Moisture mass balance in the EW humidification

If the building occupancy were to drop to 25%, with the same dry OA condition, the 25 occupants would cause the space RH to be only 15%. At the lower limit, with no occupant moisture addition, the space RH would be 11%, with or without the EW, assuming no auxiliary humidification. In order to bring the building RH up to 30% when 25% occupied, the EW effectiveness would need to be 79%. Under these conditions, an 80% effective EW would be operating at full speed continually.

Operating Cost For the sample operating cost analysis, the following assumptions will be made: Chiller electrical consumption rate: 0.7 kW/ton (5.0 COP) Electricity, $0.08/kWh or $23.50/million Btu ($0.022/MJ) Efficiency of a gas heating plant to produce steam for humidification, 80% Gas, $14.00/million Btu ($0.013/MJ) The 80% effective EW would elevate the 55°F (12.8°C) SA temperature to 70.9°F (21.6°C), which would subsequently need to be cooled back down to 55°F (12.8°C). That chiller load from 2,000 cfm (940 l/s) of air is 2.85 tons, which would cost $0.16/hr to operate. The humidification would be all accomplished via the EW. If a steam humidifier, rather than an EW, had been used to humidify the OA, the supply air humidity ratio would have to be elevated with the humidifier from 12.8 gr/lbmDA (1.8 g/kgDA) to 30.4 gr/lbmDA (4.3 g/kgDA) which would cost $0.42/hr. In this example humidification with the steam humidifier cost 220% more than it would to use the EW and sensibly cool. It may be noted that for the example OA and space conditions, the ratio of humidifier cost and chiller cost remain constant as a function of the slope of the line between the two state points. In the dry condition, increasing the slope of the line causes the ratio of humidifier cost to chiller cost to increase, and vise versa.

Binary EW Humidification Control Fig. 2. EW controller response Fig. 3. DOAS operating regions

Binary Control in Region III Region III defines OA conditions that are below the DPT necessary to maintain acceptable space RH, and DBTs exceeding the SA DBT setpoint (55°F (12.8°C) in this example). For illustration purposes Region III is divided into 2 regions, one bounded by OA DBTs between 55 (12.8°C) and 75°F (23.9°C), and a second bounded by OA DBTs greater than or equal to 75°F (23.9°C) (the example space DBT). The first region is illustrated in Fig. 4. The binary EW control in this region places the EW in the on position when the space or return air RH is below set point, recovering both heat and moisture. The resulting EW leaving conditions exceed the desired SAT, so the air is sensibly cooled to the desired SAT set point. The use of the EW for humidification here increases the cooling energy use (if not from an economizer source) beyond that needed to simply sensible cool. Once the space or return air RH set point has been met, the binary control places the EW in the off mode. Sensible cooling is still required.

Fig. 4. Region III (SA DBT setpoint < OA DBT < space DBT)

In the second region, illustrated in Fig. 5, the binary EW control behaves identical to that of Fig. 4. The difference is that operating the EW (in the on mode) for humidification results in a decrease in the DBT of the air, thus reducing the sensible cooling performed by the cooling coil compared to times when the EW is in the off mode. Note, when the EW operates in region III latent cooling at the cooling coil should be avoided. In other words, the cooling coil chilled water supply temperature setpoint should be high enough for avoiding condensation formation on the cooling coil. Otherwise, the humidification accomplished with the EW will be nullified.

Fig. 5. Region III (OA DBT > space DBT)

In region IV, much of the time the OA DBT is below freezing, so to avoid low temperature incidences (freezing) at the cooling coil (if chilled water), a freeze proof preheat coil is required to elevate the OA DBT to about 40°F (4.4°C). During periods when the space or return air RH meets or exceeds set point, and the EW is off, the OA temperature can be elevated to the SAT DBT set point with a sensible heat recovery device such as sensible wheel (SW), if it is included in the DOAS arrangement. If sensible heat recovery is not included in the arrangement, the preheat coil can be used to bring the OA up to the desired SAT. The binary control logic for this region as illustrated in Figure 6, places the EW in the on mode whenever the space or return air RH is below set point. And if necessary the air is sensibly cooled, either with a cooling coil or by parallel sensible cooling system installed in the space. In either case, waterside free cooling should be considered. If the space or return air RH is above set point, the EW is placed in the off mode. Binary Control in Region IV

Fig. 6. Psychrometric process in Region IV

Auxilary Humidification There are at least two situations where the EW may not be able to provide sufficient moisture recovery to maintain the minimum space RH prescribed by ASHRAE Standard One is at low occupancy levels. The other is extremely low OA DPTs that would require the EW effectiveness to exceed its capability. In either of these cases, in order to operate within ASHRAE standards, auxiliary humidification will be required. It should be noted, however, that not all buildings have been constructed in sufficient compliance with ASHRAE Standard to take an indoor RH of 30% in the winter without condensation problems. Some owners may not wish to use extra energy for humidification. The auxiliary humidifier, if used, would be best placed in the conditioned space. Placing it in the relatively cold DOAS supply ductwork could easily lead to water in the ductwork problems.

Binary EW Temperature Control Binary control of the EW can be used to accomplish SAT setpoint (e.g. 55°F (12.8°C)) without regard for humidification as well. In this case, the control only applies in Region IV. In order to meet a desired SAT, the EW must be duty cycled. The duty cycle concept involves adjusting the EW on time within a cycle period to achieve the desired SAT. The on time is a function of the return air temperature, the OA DBT, the desired SAT, and the EW sensible effectiveness. To limit the number of times the EW is energized per hour, and hence the wear and tear on the drive, the period is often set at 15 minutes. As a result, the on and off times are frequently long enough for the EW SAT to reach nearly its steady state on or off value, which will always be above and below the desired SAT. Consequently, control of the heating and cooling coils when in the duty cycle mode become issues. Since the SAT will drop below the desired SAT when the wheel is off in the cycle, but heating is not desired, the heating coil control valve must be closed during duty cycling. Similarly, when the EW is on in the cycle, the SAT will rise above the desired SAT, but cooling is not desired, so the cooling coil control valve must be closed during duty cycling. Duty cycling can only operate down to a lower limit, a temperature just above that necessary to trip the low limit temperature sensor. In order to avoid tripping the entire system off, and the resulting indoor environmental quality (IEQ) problems, the EW is not permitted to duty cycle below an OA DBT of 40°F (4.4°C). A freeze proof preheat coil can make this provision. An example of the duty cycle trending as the OA temperature rises above 40°F (4.4°C) is illustrated in Fig. 7. A byproduct of using binary SAT control in Region IV is that much of the time the EW is in the on mode, and humidification is being accomplished. However it is the controlled variable.

Fig. 7. Binary EW tempeature control

Conclusion A simple, proven, and generally applicable binary enthalpy wheel humidification control has been presented. The control overcomes the surprising issues discussed above that arise when modulating EW speed control is attempted during humidification. It was noted that use of an EW does not eliminate the potential need for an auxiliary humidifier. It has also been illustrated that it is less expensive to operate the chiller to achieve sensible cooling after the EW during dry OA conditions than to not use an EW and simply humidify the OA. In region III and IV, there is an energy penalty to humidify, but it is less when using the EW to humidify the OA than an auxiliary humidifier. Humidification is a worthy investment and operational expense for occupant health and productivity. For more information about DOAS: