A Portable Ultrasensitive SERF Atomic Magnetometer for Biomagnetic Measurements R Wyllie, 1 Z Li, 2 R Wakai, 3 N Proite, 1 P Cook, 1 T Walker 1 1 – Department.

Slides:



Advertisements
Similar presentations
Maxwell’s Equations & EMR.
Advertisements

Analysis of Intermodulation Distortion in Ferrite Circulators Anuj Srivastava Karen Kocharyan Presented at MTT-2003 Renaissance Electronics Corporation.
HATTIE RING PRESENTATION FOR PHYS 250 4/22/2008 Magnetometry.
(Industrial Electronics) Engr. M. Laiq Ur Rahman
What are we measuring with EEG and MEG James Kilner.
Trapping Electrons With Light Elijah K. Dunn PHSX 516, Dec. 6, 2011.
Nonlinear Magneto-Optical Rotation with Frequency-Modulated Light Derek Kimball Dmitry Budker Simon Rochester Valeriy Yashchuk Max Zolotorev and many others...
ELEG 479 Lecture #9 Magnetic Resonance (MR) Imaging
Intense Field Femtosecond Laser Interactions AMP TalkJune 2004 Ultrafast Laser Interactions with atoms, molecules, and ions Jarlath McKenna Supervisor:
Another Route to CP Violation Beyond the SM – Particle Dipole Moments Dave Wark Imperial/RAL WIN05 Delphi June 10, 2005.
Danielle Boddy Durham University – Atomic & Molecular Physics group Red MOT is on its way to save the day!
Noise near peak field is increased Peak width narrow Peak is symmetric Purpose: Resonate nuclei to prevent polarization. Matching the resonant frequencies.
Nuclear effects in the optically- detected magnetic resonance of electron spins in n-GaAs Benjamin Heaton John Colton Brigham Young University.
Nonlinear Magneto-Optical Rotation with Frequency-Modulated Light Derek Kimball Dmitry Budker Simon Rochester Valeriy Yashchuk Max Zolotorev and many others...
Electron Paramagnetic Resonance spectrometer
SPIN 2004 Oct. 14, 2004 W. Kim, S.S. Stepanyan, S. Woo, M. Rasulbaev, S. Jin (Kyungpook National University) S. Korea Polarization Measurements of the.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Thermal stability of the ferromagnetic in-plane.
Principles of Magnetic Resonance
Detection of 3He with SQUIDs. Experimental parameters For B=300 Gauss The expected signal is 220 fT (specific geometry is taken into account), while the.
Slide # 1 Velocity sensor Specifications for electromagnetic velocity sensor Velocity sensors can utilize the same principles of displacement sensor, and.
1 David P. Pappas National Institute of Standards and Technology Boulder, CO CNRS Thematic School High Sensitivity Magnetometers Sensors & Applications.
Search for an Atomic EDM with
The International Workshop on THIN FILMS APPLIED TO SUPERCONDUCTING RF AND NEW IDEAS FOR PUSHING THE LIMITS OF RF SUPERCONDUCTIVITY M. Valentino, Padova-Italy,
1 Paolo Falferi - ET WG2 meeting - Glasgow, 22/7/2010 Actuator magnetic noise measurement and possible developments Paolo Falferi CNR-FBK Trento and INFN.
A Portable Ultrasensitive SERF Atomic Magnetometer for Biomagnetic Measurements R Wyllie, 1 Z Li, 2 R Wakai, 3 N Proite, 1 P Cook, 1 T Walker 1 1 – Department.
Mikael Siltanen,1 Markus Metsälä,1
Measurements of stray field in the NLCTA area Josef Frisch, Peter Tenenbaum, Tor Raubenhemier.
Novel Approaches to Doppler-Free Ion Imaging I. Two-Color Reduced-Doppler Imaging II. Doppler-Free/Doppler-Sliced Imaging Cunshun Huang, Wen Li, Sridhar.
High Precision Mid-Infrared Spectroscopy of 12 C 16 O 2 : Progress Report Speaker: Wei-Jo Ting Department of Physics National Tsing Hua University
Michelle Espy SQUID NMR Signal Outline Overview of SQUIDs in EDM: present thinking - experimental design ideas - expected signal,
Motivation Polarized 3 He gas target Solenoid design and test 3 He feasibility test Summary and outlook Johannes Gutenberg-Universit ä t Mainz Institut.
Considerations for the Optimal Polarization of 3 He Targets Brielin C. Brown University of Virginia October 10, 2008 SPIN 2008.
Ultrahigh precision observation of nuclear spin precession and application to EDM measurement T. Inoue, T. Furukawa, H. Hayashi, M. Tsuchiya, T. Nanao,
1 Introduction to Magnetic Resonance Imaging درس مقدمه ای بر فیزیک پزشکی Sahand University of Technology Faculty of Electrical Engineering M. Shamsi.
Low-frequency nuclear spin maser and search for atomic EDM of 129 Xe A. Yoshimi RIKEN SPIN /10/11-16 Trieste, ITALY Collaborator : K. Asahi (Professor,
Beam Polarimetry Matthew Musgrave NPDGamma Collaboration Meeting Oak Ridge National Laboratory Oct. 15, 2010.
Duke nEDM Collaboration Meeting The status of 3 He Relaxation Time Measurement at ~400mK Q. Ye, D. Dutta, H. Gao, W. Zheng, X. Zhu Duke University R. Golub,
Low–field NMR (or MRI) Images of Laser polarized Noble Gas.
MRI Physics Dr Mohamed El Safwany, MD.. MRI Magnetic Resonance Imaging Magnetic Resonance Imaging.
Refractive Index Enhancement without Absorption N. A. Proite, J. P. Sheehan, J. T. Green, D. E. Sikes, B. E. Unks, and D. D. Yavuz University of Wisconsin,
3 He cell production at NIST M. Jon Dadras. Outline Basics of a 3 He cells Basics of a 3 He cells Blowing/Baking Blowing/Baking Filling Filling Uses Uses.
2007/11/02nEDM BOSTON1 Dressing Field Study Pinghan Chu University of Illinois at Urbana-Champaign nEDM Collaboration Boston Dressed.
The polarized target for G E n Gordon D. Cates, Jr. University of Virginia Professor of Physics and Radiology G E n, - October 24, 2003.
電磁撿測實驗 所謂非破壞性檢測乃是以電磁,超音波等方法來檢查物質的瑕疵或測量產品的品質,這些方法不會破壞受檢測的物體,故稱之為非破壞性檢測.
DOE 2/11/05 #1 EDM R&D Progress Steve Lamoreaux, Los Alamos Co-spokesperson for the EDM Project for presentation to The Department of Energy Cost & Schedule.
BME1450 Intro to MRI February 2002 The Basics The Details – Physics The Details – Imaging.
Brit and the Rad Lab at MIT Radiation Laboratory Series: Documented developments from the Rad Lab Volume 19 (copyright 1949): Waveforms- edited by B. Chance.
Gravitational Experiment Below 1 Millimeter and Search for Compact Extra Dimensions Josh Long, Allison Churnside, John C. Price Department of Physics,
Ultra-low Field Nuclear Magnetic Resonance Measurements with SQUIDs
Collisional Orientation Transfer Facilitated Polarization Spectroscopy Jianmei Bai, E. H. Ahmed, B. Beser, Yafei Guan, and A. M. Lyyra Temple University.
Atomic Sensors Research University of Wisconsin-Madison Thad Walker Anna Korver Dan Thrasher Mike Bulatowicz.
Study of T 1 relaxation time A proposal to test T 1 using a dilution fridge and SQUID NMA at Royal Hollow University,London.
Continuous SWIFT Djaudat Idiyatullin. , Steven Suddarth+, Curt Corum
DNP for polarizing liquid 3 He DNP for polarizing liquid 3 He Hideaki Uematsu Department of Physics Yamagata University.
R Wyllie, R Wakai, T G Walker University of Wisconsin, Madison Spin-Exchange Relaxation Free Heart signal frequency spectrum from DC-100Hz Adult heart.
Gas Phase Infrared Spectroscopy of Protonated Species Department of Chemistry University of Georgia Athens Georgia,
Alex Sushkov Dima Budker Valeriy Yashchuk (UC Berkeley) Kerr Effect-based Measurement of the Electric Field.
Anna Korver, Dan Thrasher, and Thad Walker Northrop-Grumman Review September
FSS Frequency Stabilisation System. Overview Why we need FSS:  Stabilise the optical frequency of fibre laser to +3 kHz  Use Rb frequency standard at.
15 July, 2003 PMRIL Autotuning Interventional Coils for Imaging Ross Venook 1, Garry Gold 2, Bob Hu 3 & Greig Scott 1 1.Department of Electrical Engineering,
Experimental Detection of the Magnetic Resonance signal requires setting up a non-equilibrium state What is the thermal equilibrium available to start.
K. Gireesan1, T. S. Radhakrishnan1, Joseph Bensigh3, S
Effect of small (2G) external B-field on standard PMT for magnetic moment experiment Chunyang Ding and Zhanpei Fang.
Detection of cosmological axions The QUAX R&D-activities Giovanni Carugno – INFN UNI PD for the QUAX Collaboration QUAX (lat/gr): QUaerere ‘ΑΞιον or (En):
Derek F. Jackson Kimball. Collaboration Dmitry Budker, Arne Wickenbrock, John Blanchard, Samer Afach, Nathan Leefer, Lykourgas Bougas, Dionysis Antypas.
 The electron electric dipole moment (eEDM) is aligned with the spin and interacts with the giant (~84 GV/cm) effective internal electric field of the.
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
Laser Locking for Long-term Magneto-Optical Trap Stability
Inverse Square Sensitivity
Nuclear Magnetic Resonance
Presentation transcript:

A Portable Ultrasensitive SERF Atomic Magnetometer for Biomagnetic Measurements R Wyllie, 1 Z Li, 2 R Wakai, 3 N Proite, 1 P Cook, 1 T Walker 1 1 – Department of Physics, UW-Madison 2 – Center for Clinical Neurosciences, UT-Houston Health Science Center 3 – Department of Medical Physics, UW-Madison

Requirements for Biomagnetic Measurements Sensitivity Bandwidth~100Hz Portability

Atomic SERF Magnetometer Romalis et. al., Nature, 422, 596, 2003 Note: Spin-exchange collisions do not affect  ´

Experimental Concerns For full SERF sensitivity, precession rate<<spin relaxation rate Magnetic shielding, careful nulling using Helmholtz coils Noise Sources –Nonmagnetic, technical noise (e.g. vibrations, thermal fluctuations, etc.) –Johnson noise (thermal electron motion)

Technical Noise from an hot air heated cell scheme

Z-Mode Goal: use lock-in technique to extract signal from nonmagnetic noise Apply a large, oscillating ~kHz magnetic field in z-direction (along pump) For best sensitivity, Larmor frequency~parametric frequency, sets B z =430nT Use lock-in detection of signal Two detection directions –Z1, S y signal oscillates at w z –Z2, S x signal oscillates at 2 w z Zero transverse fields produce no signal— background free

Z-Mode Results Significantly reduces nonmagnetic noise Retains sensitivity and bandwidth of normal SERF magnetometer operation

Current Setup Rb 87 with N2 (100T) buffer gases Circularly polarized pump at 795nm Linearly polarized probe at ~780nm Cell heated to 180 C

Technical Improvements Plastic, ceramic, and Teflon parts reduce Johnson noise, improve portability Matched resistive film heaters create little magnetic field, allow smaller apparatus, less noise (similar to Kitching et al heating scheme) RF heating, atoms not affected by high frequency (MHz) fields Insulation allows subject to be 1cm away from cell Easy conversion to gradiometer with pump tube

Adult MCG

Acknowledgments This work funded by a grant from the NIH