Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel,

Slides:



Advertisements
Similar presentations
Geometrically Optimized mPAD Device for Cell Adhesion Professor Horacio Espinosa – ME 381 Final Project Richard Besen Albert Leung Feng Yu Yan Zhao Fall.
Advertisements

Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering,
The «Lab-On-a-Chip» Concept Initiated in the 1990’s, Lab-On-a-Chip (LOC) technology represents a revolution in laboratory experimentation. The main benefits.
Laser-Assisted Direct Imprint (LADI) Technology S. Y. Chou, C. Keimel, and J. Gu, Ultrafast and direct imprint of nanostructures in silicon, Nature, 417.
PDMS processing & devices. 2 nd master PDMS 1 st master PDMS control channel active channel PDMS 3 rd substrate.
John D. Williams, Wanjun Wang Dept. of Mechanical Engineering Louisiana State University 2508 CEBA Baton Rouge, LA Producing Ultra High Aspect Ratio.
Adhesive Bonding with SU-8
INTEGRATED CIRCUITS Dr. Esam Yosry Lec. #6.
Figure 7 Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong Department of Biomedical Engineering,
Microfluidic Valve Innovation Jo Falls Porter, RET Fellow 2009 West Aurora High School RET Mentor: Dr. David T. Eddington, PhD NSF- RET Program Introduction.
CISMM: Computer Integrated Systems for Microscopy and Manipulation Collaborators: Dr. R. E. Cheney, Dept of Cell and Molecular Physiology Project Lead:
MEMS Cell Adhesion Device Andrea Ho Mark Locascio Owen Loh Lapo Mori December 1, 2006.
Zarelab Guide to Microfluidic Lithography Author: Eric Hall, 02/03/09.
The Deposition Process
MEMs Fabrication Alek Mintz 22 April 2015 Abstract
Basic Silicone Chemistry (II)
Microfluidics: Catalytic Pumping Systems Paul Longwell Hollidaysburg Area High School Summer 2005.
CS/EE 6710 CMOS Processing. N-type Transistor + - i electrons Vds +Vgs S G D.
Development of a Modular Peristaltic Microfluidic Pump and Valve System 3/13/2007 BME 273 Group 20: Adam Dyess, Jake Hughey, Michael Moustoukas, Matt Pfister.
Presentation Short Title
INTEGRATED CIRCUITS Dr. Esam Yosry Lec. #2. Chip Fabrication  Silicon Ingots  Wafers  Chip Fabrication Steps (FEOL, BEOL)  Processing Categories 
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
Prototyping Techniques: Soft Lithography
Chapter 4 Overview of Wafer Fabrication
BioMEMS Device Fabrication Procedure Theresa Valentine 8/19/03.
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
Microcontact Printing
Top Down Manufacturing
Chip Lid Molding ENGR Pre Lab. Micro-fabrication  How can we produce devices on a very small scale ?  e.g. Device dimensions 10 nm – 400 µm.
Top Down Method Etch Processes
Project Update June 22, 2006 ME342A. Project Goal Design a bioMEMs substrate to apply and measure electromechanical forces in the differentiation of human.
ISAT 436 Micro-/Nanofabrication and Applications Photolithography David J. Lawrence Spring 2004.
NMOS FABRICATION 1. Processing is carried out on a thin wafer cut from a single crystal of silicon of high purity into which the required p-impurities.
CORPORATE INSTITUTE OF SCIENCE & TECHNOLOGY, BHOPAL DEPARTMENT OF ELECTRONICS & COMMUNICATIONS NMOS FABRICATION PROCESS - PROF. RAKESH K. JHA.
BioMEMS Device Integration, Packaging and Control for BioMEMS
SU-8 is a polymer EPON SU-8
Stage st Trial Problems Thickness of PDMS layers Interconnects Delamination Air bubbles.
Optimization of T-Cell Trapping in a Microfluidic Device Group #19 Jeff Chamberlain Matt Houston Eric Kim.
1 Overview of Fabrication Processes of MOSFETs and Layout Design Rules.
Process Sequence: Pressure-Actuated Valve ENMA490 October 14, 2003.
Electrochemical Bubble Valves Center for Bio-Mems,State University of NewYork at Buffalo.
Optimization of T-Cell Trapping in a Microfluidic Device Group #19
C A microfluidic device was created in order to mix the contents of two reservoirs through a 200um-wide, 30mm-long diffusion channel. Flow Characterization.
Deflection of PDMS ENMA 490 October 16, 2003 Shawna Dean.
CMOS FABRICATION.
MICROCHANNEL DESIGN ISSUES Susan Beatty Anne Samuel Kunal Thaker.
Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel,
Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel,
A) < 1 so the flow is definitely laminar. Note that this is a quite large channel with very fast flow. (You could also use hydraulic radius instead of.
Microfluidic generator of sub-10-micron hydrosomes Zhenghao Ding, Lunjun Liu, Gabriel C. Spalding* Physics Department, Illinois Wesleyan University Abstract.
Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel,
Separation Techniques Using Microfluidics
Date of download: 9/18/2016 Copyright © ASME. All rights reserved. From: Droplet Detachment Mechanism in a High-Speed Gaseous Microflow J. Fluids Eng.
Utah Nanofab Design Review Meeting Device Architecture (Top View Layout and Layer Cross Section) Recipes & Settings Standard Concept Equipment & Tools.
Date of download: 9/26/2017 Copyright © ASME. All rights reserved.
Mask Design for Molds.
Date of download: 10/17/2017 Copyright © ASME. All rights reserved.
Fluid Resistance: Micro-channels of the Valve Design
Chapter 1 & Chapter 3.
Molding PDMS Channels and an Embedded Detector Chamber
BioMEMS Device Fabrication Procedure
Device Design: Stage 2 (Modified Microchannel Design)
Pressure Actuated Valve Test Design
Microfluidic Biochips
Device Design: Stage 2 (Modified Microchannel Design)
SILICON MICROMACHINING
Preliminary control integration
Applications and Acknowledgements
Mask Design for Molds.
Multilayer Microfluidics
Presentation transcript:

Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel, K. Thaker

Problem Definition Motivation –BioMEMS research is growing rapidly, but restricted to single layer microfluidics –Development of a multilayer microfluidic design would increase flexibility Goal –Design, construct, and test a controllable microfluidic device with at least two fluid levels –Identify appropriate materials, processes, and device geometries

Problem Scope Requirements –To make a two-level microfluidic device –To incorporate active control elements Constraints –Assume external fluid control –Neglect biochemical reactions in channels –Keep design feasible for manufacturing

Initial Material Choices Desired Characteristics Ease of patterning and use in microfabrication Chemically inert Low Cost / Obtainable Optically transparent Specific Elastic modulus (flexible, rigid)

Initial Material Choices Substrate Material Silicon Relatively inexpensive Commonly used in microelectronics Well known properties and processing techniques Pyrex Transparent to visible light Allows visual monitoring of micro channels More expensive than silicon

Initial Material Choices Microchannel Material Poly(dimethylsiloxane) or PDMS Inexpensive Poor surface adhesion – releasable from mold Highly flexible modulus of 2.5 MPa SU-8 Is a photoresist High aspect ratios obtainable Good surface adhesion to silicon and pyrex Very rigid – complementary to PDMS modulus of 4000 MPa

Project Development Defined Problem Divided into research groups (BioMEMS, Materials, Devices, and Circuits) Developed Stage 1 (Initial Microchannel Design Concept) Developed and tested Stage 2 (Modified Microchannel Design) Modified design to integrate vertical vias for multilevel fluid flow Developed and tested Stage 3 (Final Design: Pressure Actuated Valve Design) Developed fluid control device to manipulate fluid flow Summarized manufacturing and experimental results of final design

Device Design: Stage 1 (Initial Microchannel Design Concept) Objective –To create an initial design for a multilayer micro fluidic device Initial design elements –90 o orientation of fluid layers –Vertical interconnects at channel intersections –Each layer has same design- reduces number of molds –Versatility of fluid paths Bottom layer Middle layer Top layer I/O

Device Design: Stage 1 (Initial Microchannel Design Concept) Materials –Stackable PDMS layers –Silicon substrate –SU-8 molds Processes –Create a channel mold and an interconnect mold using SU-8 –Create PDMS layers from SU-8 mold: two layers from channel mold, one interconnect layer –Stack layers on substrate starting with a channel layer, interconnect layer and second channel layer at 90 o orientation

Device Design: Stage 2 (Modified Microchannel Design) Objective –To test the viability of a two-level passive micro-fluidic device Modifications from Stage 1 –Moved reservoir positions to fit existing packaging –Created discrete flow paths to test flow on individual layers and between layers –Increased all dimensions to facilitate fabrication and testing Device Logic –Five distinct fluid paths –11 I/O –Two distinct channel levels –One interconnect level –One Top Cover level

Device Design: Stage 2 (Modified Microchannel Design) Device Geometry –Chosen for process compatibility –Rectangular micro-channels –Square Interconnects –Circular reservoirs Materials –SU-8 used as a mold for the PDMS layers –All PDMS layers stacked on a Silicon substrate Critical Dimension Value PDMS Layer Height 100  m Micro-channel Width 500  m Interconnect Width 1000  m Interconnect Depth 1000  m Reservoir Diameter 0.4 cm

Device Design: Stage 2 (Modified Microchannel Design) Process Sequence and Mask Design 1.Begin with four polished Si wafers 2.Spin SU-8 (negative photoresist) on the Si wafers and pre- bake at 95°C 3.Align each of the four wafers with one of the four masks shown below and expose the SU-8 to ultraviolet light, then post-bake at 95°C 4.Develop the SU8 so that the unexposed areas are removed –Results in four distinct SU8 molds Micro-Channel Layer 1 Interconnect Layer Micro-Channel Layer 2 Top Cover Layer

Device Design: Stage 2 (Modified Microchannel Design) 5. Spin PDMS on the SU8 molds less than the vertical dimension of the SU-8 protrusions –Mix PDMS (Sylgard 184, Dow-Corning) 10:1 with curing agent –Spin on PDMS –Dip the Si wafer in a sodium dodecyl sulfate(SDS) adhesion barrier and allow it to dry naturally –Bake in box furnace for 2 hours at 70°C 6. Delaminate and stack all four PDMS layers in the following order: Micro-channel Layer 1, Interconnect Layer, Micro-channel layer 2, Top Cover Layer Micro-Channel Layer 1 Interconnect Layer Micro-Channel Layer 2 Top Cover Layer

Device Design: Stage 2 (Modified Microchannel Design) Final Expected Result:

Stage st Trial Problems Thickness of PDMS layers Interconnects Delamination Air bubbles

Stage nd Trial Fabrication Successfully made and aligned four layers Layers had very few defects All interconnects joined two different layers Entire wafer looked very good- no rough edges, no air bubbles between layers, no craters

Phase nd Trial Successes & Problems Liquid to flow in all channels –all the way through 2 out of 5 channels Tracked fluid flow using bright food coloring Tested the effects of vertical interconnects No capillary action –had to use pressure from syringe problems Pressure caused delamination Effects of vertical interconnects

Phase 2 – Experimental Procedure

Phase 2 – Channel Layout

Processing Problems Substantial amount of cracks in SU-8 layer Layer alignment problems –Razor blade/ tweezers method –Layer thickness –Wrinkles –Air pockets Cracks in reservoir region of SU-8 mold

Processing Problems Continued Feature alignment –Extremely difficult –Inaccurate Interconnect layer –No connection provided –Problem with layer thickness

Device Design: Stage 3 (Pressure Actuated Valve Test Design) Device Objective –To integrate an active control element into a basic microchannel design based on Stage 2 Modifications from Stage 2 –Removed all microchannels except for T-shaped section –Added a completely top layer microchannel –Incorporated negative pressure gas valves in design (Figure _) Device Logic –Two distinct fluid paths –Five I/O –Two channel levels –One gas channel level –One thin flex layer –One top cover layer

Device Design: Stage 3 (Pressure Actuated Valve Test Design) Device Objective –To integrate an active control element into a basic microchannel design based on Stage 2 Modifications from Stage 2 –Removed all microchannels except for T-shaped section –Added a completely top layer microchannel –Incorporated negative pressure gas valves in design (Figure _) Device Logic –Two distinct fluid paths –Five I/O –Two channel levels –One gas channel level –One thin flex layer –One top cover layer

Device Design: Stage 3 (Pressure Actuated Valve Design) Using the membrane dimensions for Stage 3 and a projected maximum deformation between micrometers a pressure difference of torr is needed. Deflection Equation w =0.0318(ab) 2 (1- v)/(E*t 3 ) P: pressure E: elastic modulus v: poisson’s ration a and b: width and length of membrane w: maximum deflection openclosed

Device Design: Stage 3 (Pressure Actuated Valve Test Design) Device Geometry –Made for feasibility –4 gas control sites –1 fluid interconnect –Thin PDMS flex layer Materials –SU-8 for rigid portions in valve design (gate) –SU-8 for fluid layers –PDMS for gas control layer –PDMS used for flexible gas/fluid membrane –2 substrates required (Si, Pyrex) Critical Dimension Value SU-8 Layer Height100 µm PDMS Layer Height 100 µm PDMS Flex Layer50 µm Micro-channel Width 500 µm Interconnect Width1000 µm Interconnect Depth1000 µm Reservoir Diameter 0.4 cm

Device Design: Stage 3 (Pressure Actuated Valve Design) Fluid Flow Modeling –Assumed Fluid Flow Rate based on Fluid velocity Based on literature search: 1500 cm/minute= 2.5 E5 μm/sec 1.25 E 10 μm 3 /sec= cm 3 /sec –Fluidic Resistance: R= ΔP/Q [(N*s)/m 5 ] R(circular cross section)= 8μL/(πr 4 ) –μ= Fluid Viscosity= 0.01 g/sec*cm –L= Length of channel –r= Radius of channel R(Rectangular cross section)~ 12μL/(wh 3 ) –w= Width of the channel –h= Height of the Channel Total Fluidic Resistance = R r + R c + R i + R v R r + R c + R i + R v R Total

Device Design: Stage 3 (Pressure Actuated Valve Design) Fluid Flow Modeling –Determined the velocity, fluidic resistance, Reynolds number, and pressure gradient in each section of the fluids path and found the relevant total fluid path properties Sample output for the two valve fluid path –Total Pressure Gradient ~15330Pa~115 Torr –Pressure Gradient at the Valve 3750 Pa~28 Torr –Fluid Flow Rate 1.25 E 10 μm 3 /sec= cm 3 /sec –Total Cycle Time ~21.2 seconds

Processing Problems Substantial amount of cracks in SU-8 layer Layer alignment problems –Razor blade/ tweezers method –Layer thickness –Wrinkles –Air pockets Cracks in reservoir region of SU-8 mold

Processing Problems Continued Feature alignment –Extremely difficult –Inaccurate Interconnect layer –No connection provided –Problem with layer thickness

Alternative Designs Phase Change Bubble Valve –Design Elements Isolated fluid chamber Membrane division between chamber and fluid channel Stopper to aid in the control of the fluid –Principles of Actuation Volatile liquid (cyclopentane) Resistive heaters Heater cause fluid to change from liquid to gas Expansion form gas pressure deflects membrane

Alternative Designs Phase Change Bubble Valve –Associated Problems How much pressure is needed to deflect membrane How much power is needed to create enough heat How quick is the reverse reaction

Alternative Designs (Piezoelectric) Piezoelectric Valve –Design Elements Isolated liquid chamber Membrane division between chamber and fluid channel Partial gate to aid in closing of valve –Principles of Actuation Piezoelectric material electrically activated Expansion causes compression in liquid chamber Compression translated to membrane deformation with larger amplitude

Future Work Here are a few material changes we would pursue if time allowed: Replace Pyrex with acrylic for the top substrate Promote adhesion or a seal between the PDMS layers Alter surface chemistry of the channels to be hydrophilic

Summary