RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1JLAB12.

Slides:



Advertisements
Similar presentations
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1RICH.
Advertisements

NDVCS measurement with BoNuS RTPC M. Osipenko December 2, 2009, CLAS12 Central Detector Collaboration meeting.
CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
HARP Anselmo Cervera Villanueva University of Geneva (Switzerland) K2K Neutrino CH Meeting Neuchâtel, June 21-22, 2004.
Ozgur Ates Hampton University TREK Experiment “Tracking and Baseline Design” And OLYMPUS Experiment “Study of Systematics” 1.
USE OF GEANT4 FOR LHCB RICH SIMULATION S. Easo, RAL, LHCB AND ITS RICH DETECTORS. TESTBEAM DATA FOR LHCB-RICH. OVERVIEW OF GEANT4 SIMULATION.
Could CKOV1 become RICH? 1. Characteristics of Cherenkov light at low momenta (180 < p < 280 MeV/c) 2. Layout and characterization of the neutron beam.
E-  identification 1. Reminder from previous presentations, questions, remarks 2. Čerenkov option 3. Study of several optical configurations 4. Conclusions.
Marco Musy INFN and University of Milano-Bicocca Pylos, June 2002 Aerogel as Cherenkov radiator for RICH detectors for RICH detectors.
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
Position Sensitive SiPMs for Ring Imaging Cherenkov Counters C.Woody BNL January 17, 2012.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
Medium heavy Λ hyper nuclear spectroscopic experiment by the (e,e’K + ) reaction Graduate school of science, Tohoku University Toshiyuki Gogami for HES-HKS.
Detection of Cerenkov light emission in LAr Ettore Segreto University of L’Aquila Ettore Segreto University of L’Aquila Cryodet International Workshop.
GlueX Particle Identification Ryan Mitchell Indiana University Detector Review, October 2004.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
EIC Detector – JLab – 04/June/2010 Cisbani / HERMES RICH 1 HERMES: Forward RICH Detector Evaristo Cisbani / INFN-Rome Sanità Group Most of the slides from.
D. Di Bari 1 IV Workshop on RICH Detectors, 5-10 June 2002 Pylos, Greece Methods of Cherenkov pattern recognitions in high multiplicity environments HMPID.
A RICH with Aerogel for a hadron machine On behalf of the LHCb RICH group Some results and considerations on: Cerenkov angle resolution from aerogel Index.
Status of GlueX Particle Identification Ryan Mitchell September 10, 2004.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
A RICH detector for CLAS12 CLAS12 European Workshop February 25-28, Genova, Italy Evaristo Cisbani INFN Rome and ISS Patrizia Rossi INFN- Laboratori.
The 21st International Conference on Ultrarelativistic nucleus-nucleus collisions, March 30 – April 4, Knoxville, TN Results from cosmics and First LHC.
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
Simulations Report E. García, UIC. Run 1 Geometry Radiator (water) 1cm x 2cm x 2cm with optical properties Sensitive Volume (hit collector) acrylic (with.
Dihadron production at JLab Sergio Anefalos Pereira (INFN - Frascati)
CLAS12 Rich Imaging Cherenkov Counter
Status Report particle identification with the RICH detector Claudia Höhne - GSI Darmstadt, Germany general overview focus on ring radius/ Cherenkov angle.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
Optics, Tracking, and TOF Status/Update/Roadmap Xin Qian KRL Caltech.
Mauro Iodice INFN Roma (Italy) Hall A Collaboration Meeting - JLAB May 18, 2004.
Simulations of Light Collection Efficiency (JLab Hall C 12 GeV Kaon Aerogel Detector) Laura Rothgeb Nuclear Physics Group Catholic University of America.
RICH detector for CLAS12 CLAS12 Technical Workshop P. Rossi Laboratori Nazionali di Frascati - INFN.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1 JLAB12.
TMD flavor decomposition at CLAS12 Patrizia Rossi - Laboratori Nazionali di Frascati, INFN  Introduction  Spin-orbit correlations in kaon production.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
Radia Sia Syracuse Univ. 1 RICH 2004 Outline:  The CLEO-III RICH Detector  Physics Requirements  CLEO-III RICH at work… Performance of the CLEO-III.
Contalbrigo Marco INFN Ferrara 14 th ICATPP Conference, 25 th September 2013.
Tests of a proximity focusing RICH with aerogel as radiator and flat panel PMT (Hamamatsu H8500) as photon detector Rok Pestotnik Jožef Stefan Institute,
MEIC Detector and IR Integration Vasiliy Morozov, Charles Hyde, Pawel Nadel-Turonski MEIC Detector and IR Design Mini-Workshop, October 31, 2011.
Il Ring Imaging CHerenkov (RICH) detector a Jefferson Lab – Hall A.
LG, CEDAR Optics Simulation 1 Generate rays according to momentum, mass, n-1, Pressure Uniform over length of counter, uniform over in
P HOTON Y IELD DUE TO S CINTILLATION IN CF4 Bob Azmoun, Craig Woody ( BNL ) Nikolai Smirnov ( Yale University )
A Simple Monte Carlo to understand Cerenkov photons propagation and light collection in a single crystal equipped with two PMs Alessandro Cardini / INFN.
RICH studies for CLAS12 L. Pappalardo1 Contalbrigo Marco Luciano Pappalardo INFN Ferrara CLAS12 RICH Meeting – JLab 21/6/2011.
CKOV1 design status 1. Generation of muon and pion beam files 2. PID performances with water radiator 3. Does it help with fluorocarbon FC72 ? 4. Conclusion.
Struttura del nucleone: TMD Il RICH e HD-Ice per CLAS12 Marco Mirazita (LNF)
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Focusing Aerogel RICH Optimization A.Yu.Barnyakov, M.Yu.Barnyakov, V.S.Bobrovnikov, A.R.Buzykaev, V.V.Gulevich, S.A.Kononov, E.A.Kravchenko, A.P.Onuchin.
Particle Identification (PID) at HIEPA Experiment
CLAS12 – RICH RICH - TECHNICAL PARAMETERS PARAMETER DESIGN VALUE
The focusing mirror system
Status of GEANT4 in LHCb S. Easo, RAL, The LHCb experiment.
Production of Cesium Iodide Photocathodes for
Kaons Propagation Through Nuclei
Contalbrigo Marco INFN Ferrara RICH 2016, September 9th 2016, Bled
Simulation results for the upgraded RICH detector in the HADES experiment. Semen Lebedev1,3, Jürgen Friese2, Claudia Höhne1, Tobias Kunz2, Jochen Markert4.
Particle Identification in LHCb
RICH detector for CLASS12
RICH simulation for CLAS12
Upgrade magnets and power supplies
… continue with realistic particle
RICH detector for CLAS12 … continue to explore feasibility of proximity focusing RICH in LTCC sector(s) INFN-Rome and ISS CLAS12-RICH Working Group Meeting.
Upgrade magnets and power supplies
RICH simulation for CLAS12
E.A.Kravchenko on behalf Novosibirsk group
Presentation transcript:

RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1JLAB12 coll. Meeting 18 Nov 09

RICH detector Substitute 2 LTCC sectors with a proximity RICH detector 3 cm 80 cm GeV /c  /K TOF LTCC HTCC  /p TOF LTCC HTCC K/p TOF LTCC  ratio K/  ~ M. Contalbrigo2JLAB12 coll. Meeting 18 Nov 09

Simulation with realistic phase space To detemine the best photon detector size, ,K,p have been generated at the LTCC-RICH entrance window according with a realistic phase space distribution of reconstructed momenta and angles. (GeV/c) M. Contalbrigo3JLAB12 coll. Meeting 18 Nov 09

UV light  Hall-A approach  Multiwire chambers (with CSI) suitable as cheap photon detector of large area M. Contalbrigo4JLAB12 coll. Meeting 18 Nov 09

 Old GEANT3/Fortran/PAW based MonteCarlo framework the same used the for the development of the Hall A Proximity RICH but with different geometry and size!  Charged particles phase space at the LTCC-RICH entrance window from CLAS simualtion, same distribution for ,k,p  Use arcs as radiator and detector geometries (see next)  Limitation on photon production (~3000) old memory constraint. This becomes relevant for radiator thickness > cm Main output parameter:  k  = mean error on Cherenkov angle reconstruction of k and  Monte Carlo studies: framework CC CKCK    K-  = (  K +   )/2 M. Contalbrigo5JLAB12 coll. Meeting 18 Nov 09

Points: MonteCarlo, Curves: analytical functions ~ 1 mr difference  C 5 F 12 mandatory! Geometry from the previous example Radiator Type for UV light C 5 F 12 C 6 F 14 CC CC   nn M. Contalbrigo6JLAB12 coll. Meeting 18 Nov 09

Typical spectrum for a generic PM 1/100, 90 % eff 1/100, 75 % eff M. Contalbrigo7JLAB12 coll. Meeting 18 Nov 09

UV light  Hall-A approach  Multiwire chambers (with CSI) suitable as cheap photon detector of large area  C 6 F 14 has not enough discrimination power at large momenta  C 5 F 12 is technologically challenging: liquid only below 29 o needs 0 o to keep same vapor pression of C 6 F 14 M. Contalbrigo8JLAB12 coll. Meeting 18 Nov 09

Idea: why not visible light with C 6 F 14 ?  Much reduced cromatic error  Longer absorption length -> higher number of p.e.  Higher cost due to photomultiplers  Higher material budget before ECAL M. Contalbrigo9JLAB12 coll. Meeting 18 Nov 09

Simulation based on most conservative n (Moyssdes) M. Contalbrigo10JLAB12 coll. Meeting 18 Nov 09

Quartz absorption length and refraction index from Khashan and Nassif, Optic communications 188 (2001) 129 M. Contalbrigo11JLAB12 coll. Meeting 18 Nov 09

Typical spectrum for a generic PM M. Contalbrigo12JLAB12 coll. Meeting 18 Nov 09

Accounting in addition for 0.65 efficace detection efficiency M. Contalbrigo13JLAB12 coll. Meeting 18 Nov 09 C 6 F 14 C 5 F 12

No improvement at a variance with expectations:  Reduced chromatic error (uniform refr. Index)  Increased photon number (larger abs. length) M. Contalbrigo14JLAB12 coll. Meeting 18 Nov 09 C 6 F 14 C 5 F 12

M. Contalbrigo15 No difference in the Cerenkov angle resolution JLAB12 coll. Meeting 18 Nov 09 C 6 F 14 C 5 F 12

Vs. track angle Vs. photon energy M. Contalbrigo16JLAB12 coll. Meeting 18 Nov 09

Vs. emission point M. Contalbrigo17JLAB12 coll. Meeting 18 Nov 09

Particle impact point z fixed at -5 cm (before freon) move z to 0 cm (freon surface) M. Contalbrigo18JLAB12 coll. Meeting 18 Nov 09

Vs. emission point M. Contalbrigo19JLAB12 coll. Meeting 18 Nov 09

Vs. track angle Vs. photon energy M. Contalbrigo20JLAB12 coll. Meeting 18 Nov 09

Cerenkov angle resolution improves and now scales as expected with UV vs VISIBLE light M. Contalbrigo21JLAB12 coll. Meeting 18 Nov 09 C 6 F 14 C 5 F 12

M. Contalbrigo22JLAB12 coll. Meeting 18 Nov 09

Assume: Two radiators (only 1 simulated); one per sector Detector covers up to 2 sectors (detect photons from both radiators) Radiator Polar acceptance: 5° ÷ 30°  fix radiator size ~ 4 m 2 Max gap length = 120 cm Not to scale Unit: mm and degree M. Contalbrigo23JLAB12 coll. Meeting 18 Nov 09

5°5° 25° 35° 20° 90° freon Quartz (0.5cm) gap beam line O A B A’ B’ K C C’ H H’ Space for support and neoceram ? Minimum radius fixed by 5 o requirement ? How to define maximum radius ? Study gap depth and freon thickness M. Contalbrigo24JLAB12 coll. Meeting 18 Nov 09

M. Contalbrigo25JLAB12 coll. Meeting 18 Nov 09 C 6 F 14 with visible light: similar or better than C 5 F 12 Pad size 2 cm Pad size 0.6 cm Pad size 0 cm

M. Contalbrigo26JLAB12 coll. Meeting 18 Nov 09 Hamamatsu R7400-U03: 18 mm diam., 12 mm length 0.8 x 0.8 cm 2 pixel, 50 % packing density Spectral range nm, max q.e. at 420 nm ~0.1 keu each: 1 m 2 costs about 250 keuro Hamamatsu H8500/H9500: 52 mm square. 0.6 x 0.6 cm 2 pixel, 89 % packing density Spectral range nm, 25 % q.e. at 420 nm ~1.5 keu each: 1 m 2 costs > 500 keuro Hamamatsu R M16: 26 mm square. 0.5 x 0.5 cm 2 pixel, 50 % packing density Spectral range nm, max q.e. at 420 nm ~0.5 keu each: 1 m 2 costs about 700 keuro

2<p h <3 GeV 3<p h <4 GeV 4<p h <5 GeV Correlation between track energy/angle and detector area spanned by photons might lead to cost optimization Photon detector area > 10 m 2 with x2 cm 2 PM per square meter and > 100 $ each: 2.5 M$ just enough M. Contalbrigo27JLAB12 coll. Meeting 18 Nov 09

VISIBLE light onlyMIX photon detectionUV light only The track distribution is not azimuthally uniform on the radiator surface and this results in a different performance of the two radiators due to the common photon detector. The worse case is considered. M. Contalbrigo28JLAB12 coll. Meeting 18 Nov 09 Color code is for mean number of photoelectrons 3 m 2 8 m 2

The hybrid photon detector option M. Contalbrigo29JLAB12 coll. Meeting 18 Nov 09 Pad size 2 cm Pad size 0 cm VISIBLE light Pad size 2 cm UV+VIS light UV light

A hybrid (visible + UV photons) solution under test To be compared with C5F12 and UV light at same conditions Estimate the optimal geometrical parameters – freon thickness – gap length – detector/pad size Toward real experimental conditions – ,p,k with their specific spectra – Real particle multiplicity Limit the total cost and material budget – define degrees of freedom and limiting conditions Study the C6F14 and visible light options just started Initial pessimistic estimations affected by a wrong impact z coordinate M. Contalbrigo30JLAB12 coll. Meeting 18 Nov 09

Radiation thickness Thickness (cm)X 0 (%) Entrance window Al Rohacell5152 Al Radiator Neoceram0.43 C 5 F Quartz0.54 Gap CH Photon Detector Pad NEMAG GEM chamber10.6 Total radiation thickness of the proposed RICH: ~20% X 0

Hall A RICHFactorClass12 RICH Readout (15%) MWPC: Pads Planes (8%) MWPC: Parts (Macor Insulator) (6%) Freon (C6F14) (33%) Quartz+Neoceram (24%) Mechanical Structure (12%) Evaporation Fac (exist) Freon Recirculation System20 (?)1.530 (?) Total Class12/Hall A Radiator:36-48 (min.-max. volume), 24 (surface) Detector:13 (surface), 4 (chs) GEM ~ 1.2 x MWPC k$ (estimation from Lire, CHF, $ and Euro) Costs - Very Preliminary!!

K-  Separation_old Radiator Thickness = 3 cm Gap length = 80 cm Pad/Pixel size = 0.75 cm Angle reconstruction error vs: 10K generated events

Approved Experiments requiring a RICH PR Studies of partonic distributionsusing semi-inclusive production of kaons. PR – Studies of the Boer-Mulders Asymmetry in Kaon Electroproduction with Hydrogen and Deuterium Targets. PR Studies of Spin-Orbit Correlations in Kaon Electroproduction in DIS whit polarized hydrogen and deuterium targets.

Optimal combination: Freon Thickness ~ 3 cm GAP Length ~ 80 cm PAD size < 1 cm C 5 F 12 Single sector radiator 2 sectors photon detector (26 m 2 ) Angle reconstruction error vs: Radiator Thickness, Gap length Pad/Pixel size Radiator Thickness / Proximity GAP  Note: MC statistics is poor! CC CC KK KK

The drawings inside the plot represent different detector sizes simulated Black dots: represent the black arc at different external radius Red triangle: corresponds to the red single sector Blue square: corresponds to the blue single sector with optimal external radius Green Triangle: Optimal sector (± 45 degree) and external radius Photon Detector Size

K-  Separation 80_1.5 80_280_2.5 80_3 80_3.5

K-  Separation Separation at 5 GeV/c: best case (green): 1:100 / 90% worst case (black):1:100 / 75%

Which RICH? Liquid Radiator (Freon) –May cover up to 5 GeV/c –Relatively inexpensive (proximity focusing RICH) Aerogel + Gas Radiators –May cover up to 10 GeV/c –Very expensive (cost Aerogel RICH ~ 5x Proximity Focusing RICH) M. Contalbrigo39JLAB12 coll. Meeting 20Oct09

Small “pad” size is needed only in the restricted area spanned by photon from large momentum particles Effective eff=0.65 M. Contalbrigo40JLAB12 coll. Meeting 18 Nov 09

M. Contalbrigo41JLAB12 coll. Meeting 18 Nov 09 UV LIGHT

Effective eff=0.65 Minimum pad size 2x2 cm 2 gap (assumed) 5  separation with 100 cm and 2 cm freon M. Contalbrigo42JLAB12 coll. Meeting 18 Nov 09