OUTLINE: 1.Current Design 2.Hybrids, Staves 3.Radiation Length 4.Cooling, etc.

Slides:



Advertisements
Similar presentations
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Advertisements

CO2 cooling for FPCCD Vertex Detector Yasuhiro Sugimoto KEK 1.
ATLAS SCT Endcap Detector Modules Lutz Feld University of Freiburg for the ATLAS SCT Collaboration Vertex m.
1 Integration issues of FPCCD VTX Yasuhiro Sugimoto May 22,
25/06/2015Robert King, Oxford University - Graduate Seminar Series 1 Electronic speckle pattern interferometry at the SLHC.
November Vertex 2002 Kazu Hanagaki1 Layer 0 in D0 Silicon Tracker for run2b Kazu Hanagaki / Fermilab for D0 run2b Silicon Tracker group Motivation.
(An open-ended discussion with random slides attached…) OUTLINE: Layouts Common Issues / Distinguishing Issues U-Shape L-Shape (Si and Si+Diamond) How.
Vertex2002, Kailua-Kona, HI 11/07/02 B. Quinn1 Carbon Fiber Grounding Issues in the DØ Run IIb Silicon Detector Design Breese Quinn Marvin Johnson, Mike.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
Outer Stave Prototype Update E. Anderssen, M. Cepeda, M. Garcia-Sciveres, M. Gilchriese, N. Hartman, J. Silber LBNL W. Miller, W. Shih Allcomp, Inc ATLAS.
VG1 i T i March 9, 2006 W. O. Miller ATLAS Silicon Tracker Upgrade Recent Study Topics Full length model with wafers, hybrids and cable as dead weight.
Novel technologies and materials for thermal management
CO2 cooling pressure drop measurements R. Bates, R. French, G. Viehhauser, S. McMahon.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
1 Denis Grondin – Sept.23 TH, 2010 Cooling & mechanics status CALICE Collaboration Casablanca at LPSC ECAL.
27 January 2010 Immanuel Gfall (HEPHY Vienna) Belle II SVD Mechanics and Cooling DEPFET Meeting Prag.
Material calculation of petal core variants Sergio Díez Cornell with input from many people CERN AUW, 3 rd Nov 2014.
Status overview of the cooling 31 August 2015 Bart Verlaat, Raphael Dumps 1.
18 November 2010 Immanuel Gfall (HEPHY Vienna) SVD Mechanics IDM.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
Stave Core QC Peter Sutcliffe RAL 24 th Sept 2014.
1 VI Single-wall Beam Pipe tests M.OlceseJ.Thadome (with the help of beam pipe group and Michel Bosteels’ cooling group) TMB July 18th 2002.
1 S. Coelli, M. Monti - INFN MILANO Istituto Nazionale di Fisica Nucleare Sezione di Milano LHCb – UT TRACKER UPGRADE 30 September 2013 UT TRACKER DETECTOR.
, T. Tischler, CBM Collaboration Meeting, GSI Status MVD demonstrator: mechanics & integration T.Tischler, S. Amar-Youcef, M. Deveaux, D. Doering,
Low mass carbon based support structures for the HL-LHC ATLAS pixel forward disks R. Bates* a, C. Buttar a, I. Bonad a, F. McEwan a, L. Cunningham a, S.
VG1 i T i March 9, 2006 W. O. Miller ATLAS Silicon Tracker Upgrade Upgrade Stave Study Topics Current Analysis Tasks –Stave Stiffness, ability to resist.
Ideas for LC mechanics (we will work on sensors as well – particular CMOS)
Update on UT cooling specifications and status of activities LHCb CO2 cooling meeting 8/7/2015 Simone Coelli For the Milano UT group INFN milano 1 Istituto.
BTeV Pixel Substrate C. M. Lei November Design Spec. Exposed to >10 Mrad Radiation Exposed to Operational Temp about –15C Under Ultra-high Vacuum,
Cooling R&D at RWTH Aachen Lutz Feld, Michael Wlochal (RWTH Aachen University) CEC Meeting, CERN Lutz Feld, Michael Wlochal (RWTH Aachen University)
Update on module mounting on staves and stavelets 13/6/11 1 1) Status of clean room for next assembly kit 2) DC to DC stave.
Design Discussion of Mechanical / Electrical Interfaces Bill Cooper (Fermilab) (Layer 1) VXD.
LHCb VELO Meeting LHCb VELO Cooling System Bart Verlaat (NIKHEF) 25 February 2003.
CLAS12-RICH Mechanical Design Status-Report CLAS12 RICH Review September 5-6 th 2013 S. Tomassini, D. Orecchini1 D. Orecchini, S. Tomassini.
CPPM Pixel Evaporative Cooling Plant Description & Operation with C 3 F 8 or C 4 F 10 G. Hallewell, CPPM, Feb 07, 2005.
PHENIX Silicon Vertex Tracker. Mechanical Requirements Stability requirement, short and long25 µm Low radiation length
M. Gilchriese U.S. Pixel Mechanics Overview M. G. D. Gilchriese Lawrence Berkeley National Laboratory April 2000.
W.O. Miller i T i VG 1 Two Pixel Configurations Under Study First: A Monolithic Integrated Structure First: A Monolithic Integrated Structure –Axial array.
1 VI Single-wall Beam Pipe Option: status and plans M.Olcese TMB June 6th 2002.
Stave 130 Geometry Peter Sutcliffe ATLAS Strips WP4 Meeting 26 th March 14 Liverpool.
12/3/2015R. Mountain, Syracuse University LHCb CO2 Cooling EDR2.
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
. Si upgrade workshop, 9 June Hubert van Hecke Si Upgrade - Mechanics Review of Hytec study Mounting scheme Services.
Walter Sondheim 6/9/20081 DOE – Review of VTX upgrade detector for PHENIX Mechanics: Walter Sondheim - LANL.
A hollow stave Ian Wilmut – August LBL stave At the March UG week LBL showed a prototype asymmetric stave. This prompted consideration of the strip.
10 September 2010 Immanuel Gfall (HEPHY Vienna) Belle II SVD Upgrade, Mechanics and Cooling OEPG/FAKT Meeting 2010.
Technical Design for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
News on Mechanical Design Dirk Wiedner July /4/20121Dirk Wiedner Mu3e meeting Zurich.
Progress in the Development of Evaporative Cooling Systems for the ATLAS Inner Silicon Tracker G. Hallewell 1 and V. Vacek 2 1 Centre de Physique des Particules.
B [OT - Mechanics & Cooling] Stefan Gruenendahl February 2, 2016 S.Grünendahl, 2016 February 2 Director's Review -- OT: Mechanics &
7 February 2012 Annekathrin Frankenberger (HEPHY Vienna) Open CO 2 Cooling System at the beam test Belle II SVD-PXD Meeting.
24 September 2012 Immanuel Gfall (HEPHY Vienna) SVD Status of Mechanics PXD-SVD Meeting Göttingen.
24 September 2012 Immanuel Gfall (HEPHY Vienna) Annekathrin Frankenberger (HEPHY Vienna) SVD Status of Mechanics PXD-SVD Meeting Göttingen.
13 May 2011 Eddy Jans 0 Plans for the VELOpix-module LHCb-Nikhef discussion some specifications some requirements some ideas about the VELOpix-module some.
EC: 7 DISK concept Preliminary considerations
Stave thermal analysis Cooling connections CO2 warm Test
2016/12/6 Yasuhiro R&D status of a gas-compressor based 2-phase CO2 cooling system for FPCCD vertex detector 2016/12/6 Yasuhiro Sugimoto.
Feedback on transfer line sizing and flow calculations for UT
Micro Vertex Detector of PANDA Status of Strip BARREL and DISC
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Technical Design for the Mu3e Detector
Hybrid Pixel R&D and Interconnect Technologies
update on UT cooling system
FP420 Detector Cooling Thermal Considerations
WG4 – Progress report R. Santoro and A. Tauro.
Pixel CO2 Cooling Status
Detector Technology Group
CO2 Cooling IPNL Nick Lumb, 28/01/09.
Presentation transcript:

OUTLINE: 1.Current Design 2.Hybrids, Staves 3.Radiation Length 4.Cooling, etc.

CURRENT DESIGN (ALMOST) R. Mountain, Syracuse University UT Tracker Discussion, 16 July Support Structure column geometry stiff, stable no twisting (wb) no therm motion no vibr modes Superstructure massive frame outer box Hybrid mounting front & back Permanent wirebonds Cabling readout flex service flex (only shown for central columns) Beampipe Interface clearance BP movement (bumpers?) heaters insulation sealing Sensors gapless coverage overlap optimization Hybrids stiff, stable wirebond support Balcony (Electronics & Services) evaporative CO 2 Cooling

HYBRID R. Mountain, Syracuse University UT Tracker Discussion, 16 July Simone & Mauro, 8 Jul 2013 Shown with stave section not to scale Currently, “hybrid” consists of… –Silicon Sensor –ASICs (4,8,16 per hybrid) –Kapton substrate a.k.a. flex circuit, or “jeff-flex” NOT kapton tape for signals, NOT kapton tape for power, NOR the combination –Epoxy layers (thermal) Silicon sensor to flex circuit ASICs to flex circuit Flex circuit to stave (may not be continuous) –Possible additional carbon fiber support The necessity of this will be determined by the mechanics, i.e. what is necessary to support and handle flex circuit Adds another epoxy layer: carbon fiber to flex circuit Caution: there is some disagreement as to whether this is formally part of the “hybrid” Originally the flex circuit plus carbon fiber was called “substrate” Remember: Hybrid is not yet designed !

HYBRIDS in PLANE Location of different types of hybrids –4 = 16-ASIC hybrid –2 = 8-ASIC hybrid –1 = 4-ASIC hybrid There are four different types of columns in this scheme This scheme gives an upper limit on the number of ASICS in order to provide a conservative estimate of power dissipation. This is not the canonical numbering. R. Mountain, Syracuse University UT Tracker Discussion, 16 July Column Type: A B C D D D D D (symmetric)

LIGHT-WEIGHT SUPPORT LBL-type Stave (ATLAS) –CFRP facings + CF foam (sandwich structure) –Embedded Ti cooling tubes –Closed structure, allows for stiffness of support, compactness, and low mass –Column as a unit, in construction and testing Modifications under test: –Reduced amount of foam –Cutouts in facings –Judicious path for cooling tubes Various constructions in progress –Quarter-length, Full-length R. Mountain, Syracuse University UT Tracker Discussion, 16 July Cooling Tubes CF Foam / Honeycomb CFRP Facing ATLAS STAVE

The SNAKE –Single tube –Flow is top-to-bottom –Probably only metal tubes feasible, to keep bends under control –Contact heat xfer from ASICs, but rely on substrate to provide heat xfer path from Si If INTERIOR COOLING –Encase cooling tubes in carbon foam –Takes ~30% of full carbon fill (tuneable) –Hybrid would be “lighter” If EXTERIOR COOLING –Not do-able, can’t snake on both sides (wrapping around sides interferes w neighboring column) VARIATIONS –Diagonal path, Sawtooth, X, etc. COOLING CARTOONS (2) R. Mountain, Syracuse University UT Tracker Discussion, 16 July mm -6- Element%RL Tubes (single) 0.048% Fluid (water+glycol 60:40) 0.037% POCOfoam0.119% Total=0.331% with faces, epoxy, etc. [manifolds] AA’ SECTION AA’ facing tube INTERIOR Old slide from RM, 12 Apr 2013

Quarter-Length STAVE w Cutouts R. Mountain, Syracuse University UT Tracker Discussion, 16 July Variations under consideration, constructed and tested … All have ribs only in “Box” configuration (these yield relative measurements only) One more design will test X with ribs in full “X” configuration RatiosKX+KBoxXOSolid(Ribs) facing/facing 0% (28%)47% (76%)31%46%75%100%— stave/stave 18% (38%)63% (83%)42%71%85%100%— stiff enough? NYNY?YY— * Numbers in parentheses refer to those cases in which the kapton is included

Radiation Length in UT Region R. Mountain, Syracuse University UT Tracker Discussion, 16 July UT Configuration in DDDB RL = 4.83% X O Four layers: XUVX RL between Z= mm, including 0.14% X O from air, and 0.34% from UT box. Overall RL between 2 <  < 4.9 is 4.30%. RL per UT plane ≈ 0.95%. …from JC Current TT Beampipe (current) Beampipe jacket now significantly thinned Sensor active region extends to R35 Radiation Length for UT Designs Outer frame, balconies (now no cooling plates)

UT Materials 9 PartsMaterial Thickness (  m) RL (%X o ) (2<  <4.9) Hybrid Sensor Si Al10 ASICSi+ Al Hybrid Flex Circuit (jeff-flex) Kapton Ground Al11 Traces, wirebonds6 Thermal epoxy100 Signal/Power Flex (tape) Kapton Ground, traces, epoxy x 11/ Stave (module, column) POCO foam3000 (½) 3460 (1757) CFRP face2x130 (½) Epoxy4 x 50 (½) Titanium 2x  =2.2, t=0.12 mm Cooling fluid- UTaX TOTAL0.95 Outer BoxGraphite,epoxy,Kevlar2 x Air430 mm0.14 UT TOTAL4.30 R. Mountain, Syracuse University UT Tracker Discussion, 16 July 2013 …from JC

Other Mechanical Issues Thermal simulation & measurements –Thermo-mechanical Simulation underway (Milano) –ASICs are heat islands with thermal barriers to movement of heat –Measurements of cooling power with thermal mockup (SU) Hybrid flex circuit & Kapton tapes –Will need to have thermal paths through the plane of the kaptons –Design of tapes underway (Milano) Epoxies –Adhesives from ATLAS/CMS (tested before and after irradiation) –Epoxies loaded with BN, etc. UT Mechanical Requirements document –To be found on twiki R. Mountain, Syracuse University UT Tracker Discussion, 16 July Simone & Mauro, 8 Jul 2013

CO2 Blow-Thru SU R. Mountain, Syracuse University UT Tracker Discussion, 16 July (MASS) FLOW METER NEEDLE VALVE BACK -PRESSURE REGULATOR HEATER (+50°C) VENT TO AIR EVAPORATION VOLUME (Stave in Insulating Box, w dry N2 flush) XX DRY-OUT INTERLOCK (last hybrid) HEAT EXCHANGER (siphon draws from liquid at bottom) VCR / SWGLK FITTINGS SAFETY RELIEF VALVE (110 atm) VENT TO AIR PRESSURE GAUGE P1 * follows from discussions with Bart Verlaat inlet manifold return manifold P = 15 atm T = –25°C P = 1 atm T = +20°C P = 57 atm T = +20°C P = 57 atm T = +20°C P = 15 atm T = –15°C * P = 15 atm T = +20°C P = 15 atm T = –25°C CO 2 O2-DEFICIENCY INTERLOCK SOLENOID VALVE PRESSURE GAUGE P2 PRESSURE GAUGE P3 P = 57 atm T = +10°C *

CO2 State Diagrams R. Mountain, Syracuse University UT Tracker Discussion, 16 July orig. Bart Verlaat, Forum Trk.Det.Mech 2013 ← Critical Point (31°C, 73 atm) ← Triple Point (–57°C, 5 atm) 40 atm = 580 psi = 4 MPa – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 30 atm = 435 psi = 3 MPa – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 20 atm = 290 psi = 2 MPa – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 60 atm = 870 psi = 6 MPa – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 10 atm = 145 psi = 1 MPa – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – REF: - Pvap = 57 20°C - lobe above TP shown Mollier PH diagram