Presentation Course: Power System Presented BY: M.Hamza Usman Roll No# BSEE-01123114 Date: 10, November 2015. Section(B) To: Sir, Kashif Mehmood.

Slides:



Advertisements
Similar presentations
Chapter 30. Induction and Inductance
Advertisements

Magnetism Alternating-Current Circuits
Sources of the Magnetic Field
Electromagnetic Induction Inductors. Problem A metal rod of length L and mass m is free to slide, without friction, on two parallel metal tracks. The.
Chapter 31 Faraday’s Law.
Magnetic Circuits and Transformers
Lecture 3 Three Phase, Power System Operation Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Law of Electromagnetic Induction
1 Capacitance and Dielectrics Chapter 27 Physics chapter 27.
Walker, Chapter 23 Magnetic Flux and Faraday’s Law of Induction
Copyright © 2009 Pearson Education, Inc. Lecture 9 – Electromagnetic Induction.
III–2 Magnetic Fields Due to Currents.
The Magnetic Field The force on a charge q moving with a velocity The magnitude of the force.
CHAPTER 9 Electrical Design of Overhead Lines
CHAPTER 9 Electrical Design of Overhead Lines
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 14.1 Inductance and Magnetic Fields  Introduction  Electromagnetism  Reluctance.
Lecture7 Development of Transmission Line Models Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
EE369 POWER SYSTEM ANALYSIS Lecture 6 Development of Transmission Line Models Tom Overbye and Ross Baldick 1.
Chapter 29 Electromagnetic Induction and Faraday’s Law
1 Chapter Three Electrical Concepts & Components.
Inductance and AC Circuits. Mutual Inductance Self-Inductance Energy Stored in a Magnetic Field LR Circuits LC Circuits and Electromagnetic Oscillations.
Copyright © 2009 Pearson Education, Inc. Chapter 33 Inductance, Electromagnetic Oscillations, and AC Circuits.
Power Lines The power transmission line is one of the major components of an electric power system. Its major function is to transport electric energy,
Electromagnetic Induction
Chapter 1: Introduction and DC Circuit AZRALMUKMIN BIN AZMI.
Physics.
A SAMMINAR ON ELECTRICL TRANSMISSION LINE
ELECTRICAL BASICS (Chapter 8) Electrical terms Electricity & magnetism Electricity Circuits Magnetism Electrical units Electric potential or eletromotive.
Fundamentals of Electric Circuits Chapter 6
ECE 476 Power System Analysis Lecture 7: Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Electric Forces and Fields Chapter 16. Electrical Field Maxwell developed an approach to discussing fields An electric field is said to exist in the region.
ECE 476 Power System Analysis Lecture 5:Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Review. Coulomb’s Law Units of Charge 1 Coulomb (C)
Lecture 6 Development of Transmission Line Models Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Chapter 29 Electromagnetic Induction and Faraday’s Law
It is sometimes difficult to find the polarity of an induced emf. The net magnetic field penetrating a coil of wire results from two factors.
Chapter 32 Inductance. Self-inductance Some terminology first: Use emf and current when they are caused by batteries or other sources Use induced emf.
Inductance of Single phase lines. r1 r2 D I1 I2 Consider one meter length of a signle phase line consisting of two solid round conductors of radius r.
Chapter 29 Electromagnetic Induction and Faraday’s Law
EE369 POWER SYSTEM ANALYSIS Lecture 4 Power System Operation, Transmission Line Modeling Tom Overbye and Ross Baldick 1.
VI. Electromagnetic Waves All the important physics in electromagnetism can be expressed in four Maxwell’s Equations, the Lorentz force and.
CHAPTER 26 : CAPACITANCE AND DIELECTRICS
Inductance.
Instructor :Kashif Mehmood
DR. A. O. ADEWALE Course Outline: Electrostatics, potential and capacitance, dielectrics, production and measurement of static electricity. Current, Ohm’s.
BASIC ELECTRICAL TECHNOLOGY Chapter 4 – Magnetic Circuits
President UniversityErwin SitompulEEM 9/1 Lecture 9 Engineering Electromagnetics Dr.-Ing. Erwin Sitompul President University
1 15. Magnetic field Historical observations indicated that certain materials attract small pieces of iron. In 1820 H. Oersted discovered that a compass.
Right-hand Rule 2 gives direction of Force on a moving positive charge Right-Hand Rule Right-hand Rule 1 gives direction of Magnetic Field due to current.
The basic components of an atom are:  Protons  Electrons  Neutrons Atoms are held together by electric force. Electric force is one of the most powerful.
Problem 4 A metal wire of mass m can slide without friction on two parallel, horizontal, conducting rails. The rails are connected by a generator which.
Copyright © 2009 Pearson Education, Inc. Chapter 30 Inductance, Electromagnetic Oscillations, and AC Circuits HW8: Chapter 28:18,31,40 Chapter 29:3, 30,48.
C.K.PITHAWALA COLLEGE OF ENGINEERING & TECHNOLOGY, SURAT
Copyright © 2009 Pearson Education, Inc. Chapter 30 Inductance, Electromagnetic Oscillations, and AC Circuits.
Announcements Please read Chapters 4 and 5 Quiz today on HW 2
Lecture 3-6 Self Inductance and Mutual Inductance (pg. 36 – 42)
Energy in Electrical Systems
Fundamentals of Applied Electromagnetics
Lecture 3-6 Self Inductance and Mutual Inductance
Chapter 3 Magnetostatics
Lecture 3-5 Faraday’ s Law (pg. 24 – 35)
PHYS 1444 – Section 02 Lecture #19
PHYS 1444 – Section 003 Lecture #21
EE 483 Power System 1 Lecture 5: Chapter 4 T.L. Resistance and Inductance.
Lecture 10 Biot-Savart’s Law.
Lattice (bounce) diagram
INDUCTORS, CAPACITORS AND ALTERNATING CURRENT
Electric Circuits Fall, 2017
C H A P T E R 5 Capacitance. C H A P T E R 5 Capacitance.
Lab: AC Circuits Integrated Science II.
Presentation transcript:

Presentation Course: Power System Presented BY: M.Hamza Usman Roll No# BSEE Date: 10, November Section(B) To: Sir, Kashif Mehmood

Chapter 9: Electrical Design Of Overhead Lines

Introduction:  Transmission of of electric power is done by 3-phase, 3-wire overhead lines.  An a.c. transmission line has i. resistance ii. inductance iii. capacitance constants or parameters of the line. which are uniformly distributed along its length. These are known as constants or parameters of the line.

9.1 Constants of a Transmission Line  These constants determine whether the efficiency and voltage regulation of the line will be good or poor.

(i) Resistance. It is the opposition of line conductors to current flow. ( ii ) Inductance. When an alternating current flows through a conductor, a changing flux is set up which links the conductor. Due to these flux linkages, the conductor possesses inductance.  Mathematically, inductance is defined as the flux linkages per ampere i.e Inductance, L = ψ / I (And its unit is henry) ψ = flux linkages in weber-turns I = current in amperes  ( iii ) Capacitance. Any two conductors separated by an insulating material constitute a capacitor. Capacitance exists between any two overhead line conductors. The capacitance between the conductors is the charge per unit potential difference i.e., Capacitance, C = Q / v (And its unit is farad)

9.2: Resistance of a Transmission Line  The resistance of transmission line conductors is the most important cause of power loss in a transmission line. The of a line conductor having, and is Mathematically: R = ρI l a resistance R Resistivity ρ Length l area of cross section a  In case of a 3-phase transmission line, resistance per phase is the resistance of one conductor.

9.3: Skin Effect  The tendency of alternating current to flow near the surface of a conductor is known as skin effect.  Note: For a direct current, inductance is zero and hence the current distributes uniformly over the entire cross section of the conductor.

Skin effect depends upon the factors: ( i ) Nature of material ( ii ) Shape of wire ( iii ) Diameter of wire(increases with the diameter of wire) ( iv ) Frequency (increases with the increase in frequency) skin effect is negligible when the supply frequency is low (< 50 Hz) And conductor diameter is small (< 1cm).

9.4: Flux Linkages In order to find the inductance of a circuit, the determination of flux linkages is important. We shall discuss two important cases of flux linkages. 1.Flux linkages due to a single current carrying conductor. If a conductor carrying current, This current will set up magnetic field. The magnetic lines of force will exsist inside the conductor as well as outside the conductor. Types: (i)Flux linkages due to internal flux. (ii) Flux linkages due to external flux. 2. Flux linkages in parallel current carrying conductors. As In parallel circuits the current does not remain the same but also divided into each nodes therefore flux linkages also changes.

9.5: Inductance of a Single Phase Two- wire Line A single phase line consists of two parallel conductors which form a rectangular loop of one turn. When an alternating current flows through such a loop, a changing magnetic flux is set up. Note: It may appear that inductance of a single phase line is negligible because it consists of a loop of one turn and the flux path is through air of high reluctance.

9.7: Concept of Self-GMD and Mutual-GMD ( i ) Self-GMD (D s ) ( Geometric mean distance ) The geometric mean distance between two symmetrical angular conductors is very nearly equal to the distance between corresponding points on the two conductors.  It can be proved mathematically that for a solid round conductor of radius r, the self-GMD or GMR = 0·7788 r. Factors:  self-GMD of a conductor depends upon the size and shape of the conductor  self-GMD of a conductor is independent of the spacing between the conductors.

( ii ) Mutual-GMD (Dm) ( Geometrical mean distances ) The mutual-GMD is the geometrical mean distances is from one conductor to the other conductor.  The mutual-GMD between two conductors is equal to the distance between their centres.

9.9: Electric Potential The electric potential at a point due to a charge “ is the work done in bringing a unit positive charge from infinity to that point”. Electric potential due to some important conductor arrangements. (i)Potential at a charged single conductor. ( ii ) Potential at a conductor in a group of charged conductors.

9.11: Capacitance of a 3-Phase Overhead Line In a 3-phase transmission line, the capacitance of each conductor is considered instead of capacitance from conductor to conductor. Two cases arises here: ( i ) Symmetrical Spacing. ( ii ) Unsymmetrical spacing

Important Summary: ( i ) The power loss in an overhead transmission line is mainly due to Line conductor resistance. ( ii ) If the length of a transmission line increases, its inductance is increased. ( iii ) If the length of the line is decreased, its capacitance is decreased. ( iv ) The d.c. resistance of a line conductor is less than its a.c resistance. ( v ) The skin effect is less for stranded conductor than the solid conductor. ( vi ) A neutral plane is one where electric intensity is zero. ( vii ) If the supply frequency increases, then skin effect is increased ( viii ) If the conductor diameter decreases, inductance of the line is increased

CHAPTER REVIEW TOPICS Q1. What do you understand by the constant of an overhead transmission line? Q2. What is skin effect ? Why is it absent in the d.c. system ? Q3. Find an expression for the flux linkages (i) due to a single current carrying conductor (ii) in parallel current carrying conductors