Capnography The EMS Version By: Ryan Felish. Why Capnography? Capnography – the measurement of carbon dioxide (CO2) in exhaled breath. Capnography provides.

Slides:



Advertisements
Similar presentations
Medical Training - Monitoring -
Advertisements

LUCAS 2 Compression Device
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
CAPNOGRAPHY: THE VENTILATION VITAL SIGN Mazen Kherallah, MD FCCP Critical Care Medicine and Infectious DIsease.
Noninvasive CO2 Monitoring Technology & Clinical Applications Lonnie Martinez Director of Respiratory Care Swedish Medical Center Lonnie Martinez Director.
Optional, Advanced EMT Capnography/ End-tidal CO 2 Monitoring.
The Ultimate Vital Sign? Importance of Capnography in EMS Joshua Erdman, BS, CCEMT-P UW Emergency Education Center.
Capnography for EMS A powerful tool to objectively monitor your patients ventilatory status.
Presentation by Steve Jones Credits Capnography: The New.
Oxygen and Carbon Dioxide transport in the blood
Mechanical Ventilaton Ramon Garza III, M.D.. Indications Airway instability Most surgical patients or trauma Primary Respirator Failure Mostly medical.
Arterial Blood Gas Analysis
Figure 49.2 The Double Bind of Water Breathers. Figure 49.3 Gas Exchange Systems.
Capnography Erika A. Gibson, DVM Michigan State University
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Blood Gases: Pathophysiology and Interpretation
The Respiratory System Pharynx 2. Larynx – Houses the vocal chords 3. Trachea 4. Primary bronchi 5. Diaphragm.
UNION HOSPITAL EMERGENCY DEPARTMENT KELLY MILLS RN CEN
Capnogram Dr.C.N.Chandra Sekhar M.D. Definitions Capnometry: Measurement and numerical display of CO 2 level during resp.cycle Capnometer: Device that.
2006DigitalPro Display Function Guide Display Function Guide Tournament Team Information ________________________________________.
Dr. Jeffrey Elliot Field HBSc, D.D.S., Diplomat of the National dental Board of Anesthesia, Fellow of The American Dental Society of Anesthesia.
Objectives Discuss the principles of monitoring the respiratory system
Copyright © 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 24: Patient Assessment: Respiratory System.
Noninvasive Monitoring in The Intensive Care Unit Iskander Al-Githmi, MD,FRCSC, FCCP Assistant Professor of Surgery King Abdulaziz University.
©2010 Physio-Control, Inc. All rights reserved. LIFEPAK ® 1000 Defibrillator Orientation Guide You’re Ready.
Oxygen Use and the CNA. Signs and Symptoms to Report Unusual skin color Unusual color of lips, mucous membranes, nail beds Cool, clammy skin Slow, rapid.
Building a Solid Understanding of Mechanical Ventilation
Capnography Tom Archer, MD, MBA Clinical Professor Director, Obstetric Anesthesia UCSD July 3, 2012.
M40M Multi-Gas Monitor. Checking instrument: A. Checking instrument: 1.Turn the instrument on by pressing the power button on the control face panel for.
Ventilators All you need to know is….
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
CAPNOGRAPHY- and PULSE OXIMETRY : The Standard of RESPIRATORY Care
UTHSCSA Pediatric Resident Curriculum for the PICU CAPNOGRAPHY and PULSE OXIMETRY.
Capnography Could Make You a Rock Star! Mike McEvoy, PhD, RN, CCRN, NRP Staff RN – CTICU and Resuscitation Committee Chair Albany Medical Center, New York.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
Oxygenation And Ventilation
Arterial Blood Gases ABG. DEFINATION  An arterial blood gas (ABG) is a blood test that is performed taking blood from an artery, rather than a vein.
Capnography for the intensivist Sarah Philipson. THE END.
Presented By: Diana Gedamke, BSN, RN, CCRN Marion College - Fond du Lac Masters of Nursing Student.
CPR in the ED: R U Ok? Mike McEvoy, PhD, RN, CCRN, NRP Resuscitation Committee Chair and Sr. Staff Nurse CTICU – Albany Medical Center EMS Coordinator.
Created by Joshua English, EMT-P James Pointer, MD Mike Jacobs, EMT-P.
Principles and Clinical Application
ADVANCED CONCEPTS IN EMERGENCY CARE (EMS 483)
Carbon Dioxide Monitoring
Patient Assessment: Airway Evaluation Dr Aqeela Bano EMS 352.
Capnography: Current and Future Use by EMS Presented by: Tim Ludwig EMT-P.
Capnography Taken from Zoll Medical Corp pamphlet on Capnography.
Capnography in the intubated patient Shannon M. Reynolds Widener University.
Monitoring in Anesthesia Dr.Arkan Jaafar, M.D. Anesthesiologist,Medical college of Mosul.
Gas Exchange and Pulmonary Circulation. Gas Pressure Gas pressure is caused by the molecules colliding with the surface. In the lungs, the gas molecules.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
Freestyle Precision Pro
Capnography: Defined and Clinical Applications
Waveform capnography Version: Jan 2016.
CCU/ED Procedural sedation
Tips for putting a patient on a F-60
Basic Troubleshooting Techniques
Cameras and Lighting Ms. Murphy.
Introduction to ventilation
LIFEPAK® 1000 Defibrillator Orientation Guide
EMS Monitoring Devices: Tips and Pitfalls
Capnography and Patient Safety for Endoscopy
End Tidal CO2 (EtCO2) and Capnography
Attach Capnograph 1. Can You See CO2? NO
Transport Ventilator and Beyond!
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
Monitoring in anesthesia
Presentation transcript:

Capnography The EMS Version By: Ryan Felish

Why Capnography? Capnography – the measurement of carbon dioxide (CO2) in exhaled breath. Capnography provides an immediate picture of patient condition. Pulse oximetry is delayed. Hold your breath. Capnography will show immediate apnea, while pulse oximetry will show a high saturation for several minutes. In colorimetric capnography a filter attached to an ET tube changes color from purple to yellow when it detects carbon dioxide. This device has several drawbacks when compared to waveform capnography. It is not continuous, has no waveform, no number, no alarms, is easily contaminated, is hard to read in dark, and can give false readings.

Why Capnography While capnography is a direct measurement of ventilation in the lungs, it also indirectly measures metabolism and circulation. For example, an increased metabolism will increase the production of carbon dioxide increasing the ETCO2. A decrease in cardiac output will lower the delivery of carbon dioxide to the lungs decreasing the ETCO2.

Normal Values ETCO mm Hg is the normal value for capnography. The normal wave form appears as straight boxes on the monitor screen:

Waveform Explained A to B is post inspiration/dead space exhalation, B is the start of alveolar exhalation B-C is the exhalation upstroke where dead space gas mixes with lung gas C-D is the continuation of exhalation, or the plateau(all the gas is alveolar now, rich in C02) D is the end-tidal value – the peak concentration, D-E is the inspiration washout

Abnormal Values ETCO2 Less Than 35 mmHg = "Hyperventilation/Hypocapnia" Ph Increases (Alkalosis) ETC02 Greater Than 45 mmHg = “Hypoventilation/Hypercapnia" PH Decreases (Acidosis) Simply put, A number less than 35 means the patient is being ventilated too fast, and a number higher than 45 means the patient is ventilated too slow and is becoming acidotic.

Verifying Tube Placement Continuous end-tidal CO2 monitoring can confirm a tracheal intubation. A good wave form indicating the presence of CO2 ensures the ET tube is in the trachea. You're out (missed the chords). You have proper placement!

Extra Tips ETCO2 can be the first sign of return of spontaneous circulation (ROSC). During a cardiac arrest, if you see the CO2 number shoot up, stop CPR and check for pulses. End-tidal CO2 will often overshoot baseline values when circulation is restored due to carbon dioxide washout from the tissues. In a resuscitated patient, if you see the stabilized ETCO2 number significantly drop in a person with ROSC, immediately check pulses. You may have to restart CPR.

Function Of Our Units

Using The Printer Leave unit on after transfer, once the unit is shut off, you will not be able to print the records of the last patient. Turn printer on by pressing the mode button then face the Infrared ports at each other. On capnographer go to Menu, Printer. Be sure the values are set as: Format = Trend Tables (default value) Time Span = (set this to the max available setting) Interval = 90 seconds (other option is 15 seconds) Then press the start print button.

Notes On Our Units A patient who has a high amount of mucous or excretions may plug in inline filter and cause the unit to show incorrect readings, resort back to lung sounds and pulse ox. If you turn on the unit, but are unable to see anything, press the up arrow (contrast button) until the screen is clearly visible. Do the opposite if the screen is all black on start up. If you are still unable to view the screen, check your battery. To clean the unit, spray hero or other disinfectant onto a towel then wipe the unit and pulse ox cord. DO NOT SPRAY ANY LIQUID DIRECTLY AT UNIT OR CORD. Use of capnography is now required on all intubated patients when available. This is to replace the use of the EZ-Cap