NLC - The Next Linear Collider Project Nano beams in the ATF extraction line Marc Ross Linear collider challenges: Energy Emittance source Stability ATF.

Slides:



Advertisements
Similar presentations
ATF2: Status Update Glenn Christian (on behalf of FONT group) 10 th ATF Project Meeting.
Advertisements

Update of EXT Stripline BPM Electronics with LCLS-style Digital BPM Processors Glen White, with slides by Steve Smith 15 December 2009 ATF2.
Beam position monitors LCABD Plenary meeting Bristol, 24th March 2009 A. Aryshev, S. T. Boogert, G. Boorman, S. Molloy, N. Joshi JAI at Royal Holloway.
Preliminary Results from HOM Measurements at the Tesla Test Facility (SLAC) Josef Frisch, Kirsten Hacker, Linda Hendrickson, Justin May, Douglas McCormick,
RF Synchronisation Issues
Bob Lill Undulator Systems – BPM April 20, 2006 Undulator Cavity BPM Status and Plans.
Progress towards nanometre-level beam stabilisation at ATF2 N. Blaskovic, D. R. Bett, P. N. Burrows, G. B. Christian, C. Perry John Adams Institute, University.
Philip Burrows Third Mini Workshop on Nano Project, KEK 30/5/05 Philip Burrows Queen Mary, University of London Overview of Intra-train Beam Feedback Program.
ATF2 Q-BPM System 19 Dec Fifth ATF2 Project Meeting J. May, D. McCormick, T. Smith (SLAC) S. Boogert (RH) B. Meller (Cornell) Y. Honda (KEK)
Optical Anchor / Interferometer Status: June, 2004 Josef Frisch.
High Resolution Cavity BPM for ILC final focal system (IP-BPM) ILC2007/LCWS 2007 BDS, 2007/6/1 The University of Tokyo, KEK, Tohoku Gakuin University,
Philip Burrows LCUK Meeting, Oxford 29/01/04 Feedback on Nanosecond Timescales (FONT): FONT2 run results Dec 03/Jan 04 Philip Burrows Queen Mary, University.
Accelerator R&D on LC - Activities of ATF & STF - 1. Introduction 2. ATF 3. STF 4. Summary Seiya Yamaguchi, KEK The US/Japan Collaboration in High Energy.
Status of QBPM Electronics and Magnet Movers as of June 3 rd 2008 D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
Feedback on Nanosecond Timescales (FONT) - Review of Feedback Prototype Tests at ATF(KEK) Glenn Christian John Adams Institute, Oxford for FONT collaboration.
Status of ATF2 Cavity BPM Project Sep 29, 2005 Project Scope: Instrument both couplers ATF2 cavity BPM’s (35) Produce prototype for December cavity test.
1 FONT Results 2010 Philip Burrows Robert Apsimon, Doug Bett, Glenn Christian Michael Davis, Colin Perry, Javier Resta Lopez John Adams Institute Oxford.
1 Plans for KEK/ATF 1. Introduction 2. Related Instrumentations at ATF 3. Experimental Plans for Fast Kicker R&D at ATF Junji Urakawa (KEK) at ILC Damping.
Installation and checkout of QBPM system Hardware to be installed –Install hardware in racks –Install CPU /SIS digitizers/VMIC 3122 analog digitizers/Digital.
BPMs and HOM-BPMs for the XFEL Linac N. Baboi for the BPM and the HOM teams (DESY, CEA-Saclay, SLAC, FNAL, Cockroft/Daresbury) XFEL Linac Review Meeting,
Bob Lill Undulator Systems – BPM January 31, 2006 Undulator Cavity BPM Design and Status.
R. Kass US LC Conference 1 Design and Fabrication of a Radiation-Hard 500-MHz Digitizer Using Deep Submicron Technology R. Kass The Ohio State University.
Feedback On Nano-second Timescales: An IP Feedback System for the Future Linear Collider Requirement for a fast IP beam-based feedback system Simulation.
Energy Spectrometer for the ILC Alexey Lyapin University College London.
IP-BPM status Siwon Jang KNU. Contents The electronics repair status –Repair work status –Electronics RF test (by using Oscilloscope) –Electronics shipment.
Marc Ross Saturday, June 5, 2004 nanometer BPM status and plans.
Development of a Low-latency, High-precision, Intra-train Beam Feedback System Based on Cavity Beam Position Monitors N. Blaskovic Kraljevic, D. R. Bett,
1 ATF2 Q BPM electronics Specification (Y. Honda, ) Design System –Hardware layout –Software –Calibration Testing Production schedule ATF2 electronics.
LCLS_II High Rep Rate Operation and Femtosecond Timing J. Frisch 7/22/15.
Results on recent technology developments at ATF - Beam extraction study by a Fast Kicker - N. Terunuma, KEK LER11, Heraklion, Crete, Greece, 2011/Oct/5.
FONT Hardware Processing electronics and current beam tests Stephen Molloy Queen Mary, University of London.
Philip Burrows ATF2 project meeting 14/1/111 Plans for ATF2 IP Feedback Philip Burrows, Colin Perry John Adams Institute Oxford University.
1 ATF Instrumentation Status and Planning Justin May, Juan Cruz, Doug McCormick, Janice Nelson, Tonee Smith, John Wray 1.
Production and Installation Policy of IP-BPM ATF2 Project Meeting, 2006/12/18 Y. Honda, Y. Inoue, T. Hino, T. Nakamura.
Status of ATF Collaboration The unique test facility for ILC with a low emittance beam. Junji Urakawa, KEK LCPAC at KEK
18 December 2007 ATF Damping Ring BPM System Upgrade Joe Frisch, Justin May, Doug McCormick, Janice Nelson, Tonee Smith, Mark Woodley (SLAC) Charlie Briegel,
NLC - The Next Linear Collider Project Cavity BPM studies Marc Ross Explore uses (and limitations) of uwave cavity BPM’s Develop nanometer resolution 10x.
IP BPM’s for ATF2 Vladimir Vogel KEK May30, 2005 Third Mini-Workshop on Nano Project at ATF.
Superfast BPM Processor Scheme and First Results Stephen Molloy, QMUL 2 nd Mini-Workshop for Nano-Project at ATF.
1 ATF 2 Nanobpm (Q BPM) Electronics. Mark Slater: Cambridge Yury Kolomensky, Toyoko Orimoto: UCB Stewart Boogert, Steve Malton, Alexi Liapine: UCL Mike.
BPM for FF test (ATF2) Vladimir Vogel KEK 2nd Nano Workshop, KEK, December 12, 2004.
SLAC ESA T-474 ILC BPM energy spectrometer prototype Bino Maiheu University College London on behalf of T-474 Vancouver Linear Collider.
Design of ATF2 feedback/feed-forward systems Javier Resta Lopez (JAI, Oxford University) for the FONT project group LC-ABD meeting Birmingham, 17-18th.
ATF2: Summary of Scheduling Strategy Session Grahame Blair Feedback and Feedforward systems Fast Kicker for ILC bunch train structure Laser-wire Shintake.
ATF DR BPM Upgrade Janice Nelson, Doug McCormick, Justin May, Andrei Seryi, Tonee Smith, Mark Woodley.
Philip Burrows ATF2 project meeting 1/07/101 Plans for ATF2 IP Feedback Philip Burrows, Colin Perry John Adams Institute Oxford University.
Low-Q IP BPM Y. I. Kim *, A. Heo, E-S. Kim (KNU) S. T. Boogert (JAI) D. M. McCormick, J. May, J. Nelson, T. Smith, G. R. White (SLAC) Y. Honda, N. Terunuma,
G.R.White: F.O.N. T. From Ground Motion studies by A.Seryi et al. (SLAC) ‘Fast’ motion (> few Hz) dominated by cultural noise Concern for structures.
IoP HEPP/APP annual meeting 2010 Feedback on Nanosecond Timescales: maintaining luminosity at future linear colliders Ben Constance John Adams Institute,
Instrumentation at ATF / TTF Accelerator Test Facility (KEK) Tesla Test Facility – FLASH (DESY) ESA / LCLS (SLAC) Marc Ross, SLAC.
NLC - The Next Linear Collider Project Intra-Pulse Feedback at the NLC Interaction Point Steve Smith SLAC Snowmass 2001.
LCLS Digital BPM Processor for ATF2 Extraction Line BPMs Steve Smith 26 August 2009.
May 31, 2005Third Mini-Workshop on Nano Project at ATF (M. Ross) Plans for nanometer cavity BPM studies Energy Spectrometer evaluation (Hildreth) Integration.
Beam Instrumentation of CEPC Yue Junhui (岳军会) for the BI Group Accelerator Center, IHEP HF2014.
FONT4 Status Report Glenn Christian John Adams Institute, Oxford for FONT collaboration.
Current Status of QBPM Electronics and Magnet Movers D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
Superfast BPM Processor Scheme Stephen Molloy, QMUL Nano-Project Mini-Workshop at ATF.
Communication 40 GHz Anurag Nigam.
Dither Luminosity feedback versus Fast IP feedback
Glen White, SLAC Jan th ATF2 Project Meeting, KEK
In collaboration with P. N. Burrows, A. Latina and D. Schulte
Intra-Pulse Beam-Beam Scans at the NLC IP
Progress towards nanometre level beam stabilisation
Bunch Tiltmeter Steve Smith SLAC Snowmass July 16, 2001 Update date
NanoBPM Status and Multibunch Mark Slater, Cambridge University
Status of TTF HOM Project Aug 9, 2005
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
SuperB Linac VME Beam Position Monitor
Undulator Cavity BPM Status
Breakout Session SC3 – Undulator
Presentation transcript:

NLC - The Next Linear Collider Project Nano beams in the ATF extraction line Marc Ross Linear collider challenges: Energy Emittance source Stability ATF – well suited for RD on emittance and stability

Author Name Date Slide # 2 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC Goal – ATF Nano-BPM project Prove that nanometer sized beams can be kept in collision –short time scales – vibration –long time scales – thermal drift Steps: 1.Measure with nanometer resolution –design and test a BPM that has ~ 1 nanometer resolution 2.Study beam stability study the stability of the ATF extraction line beam 3.Stabilize with active movers/sensors Stabilize the magnets that focus the beam (they probably need it) Stabilize the BPM itself

Author Name Date Slide # 3 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC Multi-bunch feedback – final step There will still be some instability from the ring / extraction kicker It may be possible to stabilize the trajectory within a long pulse train need good – multibunch – BPM’s ‘FONT’ experiment at NLCTA 4. Use a long extracted pulse and stabilize the back section of the train FONT = Feedback On Nanosecond Timescales

Author Name Date Slide # 4 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC IP fast feedback scheme JLC/

Author Name Date Slide # 5 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC FONT setup in NLCTA Feedback on the back 2/3 of a 170 ns train –60 ns latency

1) Nano-BPM test – ATF extraction line Mechanically connect several BPM’s (4 – 5?) Must control cavity position and angle Electronics similar to tiltmeter – optimized for best possible resolution ATF ext line (BINP) – 250 nm FFTB (Shintake) – 25 nm Joe Frisch, Steve Smith, T. Shintake

Author Name Date Slide # 7 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC C-band BPM limiting resolution (Vogel/BINP) Cavity properties: For Electrons, single bunch (assumed short compared to C-band). Assume cavity time constant of 100 nanoseconds (1.6MHz bandwidth) (guess) Assume beta >> 1 for cavity. (All power is coupled out). Thermal noise energy is kT or 4x Thermal noise position (ideal) = 0.4nm Note that deposited energy goes as offset^2 and as beam charge ^2. Signal: A 1nm offset deposits 2.4x J in the cavity. Output power for 1 nm offset is 2.4x Watt. Output power for 1 cm offset (cavity aperture?) is ~25 Watts (maximum single bunch) Output power for 10 bunch train can be 2500 Watts! (Need to terminate for multi-bunch operation)

Author Name Date Slide # 8 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC Electronics, Noise and Dynamic range Thermal noise = -168dBm/Hz. Assume signal loss before amplifier = 3dB. 1.2x10-13 Watt = -99dBm Signal power after amplifier for 1nm offset = -79 dBm Dynamic range at amplifier output = 91 dB, or ~35,000:1 position, or 25 microns. –Assume maximum signal into mixer (13dBm LO) = ~8dBm. (Joe thinks this should be ~0 dBm) –Full range (1 dB compression): 8 dBm into mixer –(Note: for good linearity, probably want –20 dBm into mixer, or ~1 micron range) Mixer conversion loss ~8dB. Maximum output = 0 dBm Front end broad band amplifier – 20 dB –Assume noise figure = 3dB (better available) = -165dBm/Hz input noise. –Front end amplifier bandwidth = 10GHz -> -65dBm noise input. –Front end gain = 20dB -> -45 dBm noise power output (OK). IF amplifier – 30 dB –Final bandwidth = 1.6 MHz. Noise in band power after amplifier = -83 dBm

Cavities - assume existing C band BPMs Filters: Approximately Q=10 to help limiter. May not need if fast limiter is available. Limiters: Available from Advanced Control. 100W peak input, Limit to about 15dBm output. Try ACLM-4700F feedback limiter 0.8dB loss, 100W max pulse input, 13.5dBm max output. Unknown speed. Also see ACLM dB loss, 100W input, 20dBm max output. Amplifier: Available from Hittite with ~3dB noise figure. Stage to get ~30dB Gain. NOTE: need to find an amplifier which can survive the 15dBm output from the limiter. Hittite parts seem to only handle 5dBm. (Maybe OK pulsed?) Amplifiers available from Miteq ($$$?) with 0.8dB noise figure and 20dBm allowable input power: JS A (for future upgrade). Mixer: Use Hittite GaAs parts - likely to be radiation resistant. IF amplifier. 30dB gain, MHz. Various options from Mini Circuits or Analog modules. Need Noise Figure 2V p-p swing. Equipment

Support electronic equipment / software Digitizer: Use spare SIS (VME) units from 8-pack LLRF system. Each is 100Ms/s, 12 bit, +/-1 V (?) input signal. C-band source: Use existing ATF synthesizer. Does not need to be locked. C-band distribution amplifier. Need to drive 8 x 13dBm references. Approximately 25dBm output (including losses). Use existing ZVE-8G amplifier (purchased for tiltmeter work). C-band distribution splitter: 1:8 splitter. Probably exists, otherwise mini- circuits. Control System: Use existing controller and existing crate. Linda thinks it is easy to interface this to Matlab on a PC for data analysis. Matlab software: Use modified version of tiltmeter software. Digitizes decaying signal from cavity BPMs and reference signal, with stripline BPM as time reference. Does not require phase locked reference, or good frequency match between cavities.

Author Name Date Slide # 11 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC Mechanical X/Y Tilt Stage: Check Newport U400 mirror mounts (~$300 each). May be strong enough to move cavity. X/Y Tilt stage drive: Use picomotors (~$450/channel motor + ~300/channel for driver), or steppers (??/channel). Steppers would provide position read back. X/Y translation stage: Use existing stages.

Mechanics Mechanical Issues The ATF beam has a position jitter of ~1 micron. In order to demonstrate 1nm bpm resolution, we need to do line fits between 3 (or more) bpms. This requires a position stability for these bpms of <1nm for several pulses (10-30 seconds). For bpms spaced by meters, the ground motion and vibration will be substantially larger than this, probably hundreds of nanometers. For the final measurement the bpms must be mounted from a common reference block. That reference block must be on supports which are sufficiently soft to not transmit vibrations which can excite internal modes in the block, probably a 10Hz mechanical support frequency is reasonable. Thermal expansion of metals is ~2x10-5/C. For a 30cm scale length, this requires temperature stability of 2x10-4C in a measurement time (~1 minute). With insulation and in the controlled ATF environment this may be possible. Use if Invar or a similar low expansion mounting frame may provide a factor of 10 relaxation in this requirement. (Not more, since it is impractical to make to cavities or cavity mounts out of Invar. If the temperature requirements cannot be met, an interferometer (or "queensgate" style capacitive system) will need to be used relative to an Invar or Zerodur reference block.

Author Name Date Slide # 13 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC Plan 2) Study beam stability – pulse to pulse and long term – using nanoBPM Assume that the ATF beam is not stable at the nanometer level and cannot be made stable 3) Use the FONT feedback on a long multi-bunch train (coll with UK group) requires: 1.increasing the bandwidth of the nano BPM to ~20 MHz (from 1.5 MHz) 2.Extra long trains – lengthen the train by extracting 3 trains that were injected in a sequence 3.Installation of the FONT feedback kicker and sampler Can we stabilize the back section to the nanometer level?

Author Name Date Slide # 14 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC SLAC- KEK/ATF team: Damping rings and Final focus Karl Bane Joe Frisch Keith Jobe Doug McCormick Bobby McKee Janice Nelson Tonee Smith Jim Turner Mark Woodley P. Karataev

Author Name Date Slide # 15 Joint Workshop for 3rd Beam Physics Seminar and 8th ATF International Collaboration Meeting - Marc Ross/SLAC Electronics - digitizer Noise output = -91dBm in 1.6MHz bandwidth. Low pass filter for ~50MHz bandwidth (anti alias) assume loss 2dB. Input to IF amplifier -10dBm Maximum signal, -93dBm noise signal. Maximum signal 20dBm (2 V Pk - Pk) Digitizer: 12 bit, 100Ms/s 10 samples during decay time. Dynamic range = 13,000:1 Input level +/- 1 V peak.