47th Annual Meeting of the Division of Plasma Physics, October 24-28, 2005, Denver, Colorado ECE spectrum of HSX plasma at 0.5 T K.M.Likin, H.J.Lu, D.T.Anderson,

Slides:



Advertisements
Similar presentations
METO621 Lesson 18. Thermal Emission in the Atmosphere – Treatment of clouds Scattering by cloud particles is usually ignored in the longwave spectrum.
Advertisements

DPP 2006 Reduction of Particle and Heat Transport in HSX with Quasisymmetry J.M. Canik, D.T.Anderson, F.S.B. Anderson, K.M. Likin, J.N. Talmadge, K. Zhai.
Sub-THz Component of Large Solar Flares Emily Ulanski December 9, 2008 Plasma Physics and Magnetohydrodynamics.
Physics of fusion power Lecture 11: Diagnostics / heating.
Injector RF Design Review November 3, 2004 John Schmerge, SLAC LCLS RF Gun Thermal Analysis John Schmerge, SLAC November 3,
13th IEA/RFP Workshop – Stockholm October 9-11, D characterization of thermal core topology changes in controlled RFX-mod QSH states A. Alfier on.
49th Annual Meeting of the Division of Plasma Physics, November , 2007, Orlando, Florida Ion Temperature Measurements and Impurity Radiation in.
1 Electron Bernstein Wave Research and Plans Gary Taylor Presentation to the 16th NSTX Program Advisory Committee September 9, 2004.
NMR Background Curve Fitting Caitlyn Meditz, on behalf of the Nuclear and Particle Physics Group. Advisor K. Slifer, E. Long Overview Dynamic Nuclear Polarization.
Fast imaging of global eigenmodes in the H-1 heliac ABSTRACT We report a study of coherent plasma instabilities in the H-1 plasma using a synchronous gated.
Effect of non-Maxwellian Velocity Distributions of EC Heated Plasmas on Electron Temperature Measurements by Thomson Scattering Ge Zhuang 1,2 1. College.
Working title: Estimation of ne and Te with microwave diagnostics and investigations on profile changes with RMP Working topics: Estimation of Te from.
Sensitivity System sensitivity is defined as the available input signal level Si for a given (SNR)O Si is called the minimum detectable signal An expression.
1 ECE 480 Wireless Systems Lecture 3 Propagation and Modulation of RF Waves.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
Edge ECE measurements with the AUG CTS receiver and the effects of ELMs during H-mode Morten Stejner.
30 th EPS conference, St. Petersburg, Russia, July, 7-11, 2003 K.M.Likin On behalf of HSX Team University of Wisconsin-Madison, USA Comparison of Electron.
ECE 5233 Satellite Communications Prepared by: Dr. Ivica Kostanic Lecture 9: Satellite link design (Section 4.3) Spring 2014.
17th International Stellarator / Heliotron Workshop Princeton, USA Overdense Plasma Operation in WEGA Stellarator Matthias Otte, H.P. Laqua, S. Marsen,
The toroidal current is consistent with numerical estimates of bootstrap current The measured magnetic diagnostic signals match predictions of V3FIT Comparisons.
Characterization of core and edge turbulence in L- and H-mode Alcator C-Mod plasmas Outline: Alcator C-Mod tokamak Fluctuation diagnostics Low to high.
Fyzika tokamaků1: Úvod, opakování1 Tokamak Physics Jan Mlynář 8. Heating and current drive Neutral beam heating and current drive,... to be continued.
Electron Density Distribution in HSX C. Deng, D.L. Brower Electrical Engineering Department University of California, Los Angeles J. Canik, S.P. Gerhardt,
Measurements of plasma turbulence by laser scattering in the Wendelstein 7-AS stellarator Nils P. Basse 1,2, S. Zoletnik, M. Saffman, P. K. Michelsen and.
FEC 2006 Reduction of Neoclassical Transport and Observation of a Fast Electron Driven Instability with Quasisymmetry in HSX J.M. Canik 1, D.L. Brower.
Proposal for Relative Calibration of ECE Diagnostic System in HT-7 Tokamak. BY S. Sajjad Institute of Plasma Physics, Chinese Academy of Sciences,
52 nd APS-DPP Annual Meeting, November, 8-12, 2010, Chicago, IL Plasma Pressure / BJ Contours Poloidal dimension Radial dimension Toroidal Angle (rad)
47th Annual Meeting of the Division of Plasma Physics, October 24-28, 2005, Denver, Colorado 1 Tesla Operation of the HSX Stellarator Simon Anderson, A.Almagri,
52nd Annual Meeting of the Division of Plasma Physics, November , 2010, Chicago, Illinois Non-symmetric components were intentionally added to the.
1) For equivalent ECRH power, off-axis heating results in lower stored energy and lower core temperature 2) Plasma flow is significantly reduced with off-axis.
Measurements of Magnetic Fluctuations in HSX S. Oh, A.F. Almagri, D.T. Anderson, C. Deng, C. Lechte, K.M. Likin, J.N. Talmadge, J. Schmitt HSX Plasma Laboratory,
Helically Symmetry Configuration Evidence for Alfvénic Fluctuations in Quasi-Helically Symmetric HSX Plasmas C. Deng and D.L. Brower, University of California,
F. Caspers, S. Federmann, E. Mahner, B. Salvant, D. Seebacher 1.
APS, 44th Annual Meeting of the Division of Plasma Physics November 11-15, 2002; Orlando, Florida Hard X-ray Diagnostics in the HSX A. E. Abdou, A. F.
52nd Annual Meeting of the Division of Plasma Physics, November , 2010, Chicago, Illinois 5-pin Langmuir probe configured to measure floating potential.
53rd Annual Meeting of the Division of Plasma Physics, November , 2011, Salt Lake City, Utah When the total flow will move approximately along the.
4. Neoclassical vs Anomalous Transport: Crucial Issue for Quasisymmetric Stellarators Overview of HSX Experimental Program J.N. Talmadge, A. Abdou, A.F.
Upgrade of the HSX Thomson Scattering System HSX TS upgrade requirement K. Zhai, F. S. B. Anderson, D. T. Anderson, C. Clark, HSX Plasma Laboratory, Univ.
5.4 Stored Energy Crashes  Diamagnetic loop shows the plasma energy crashes at low plasma density  ECE signals are in phase with the energy crashes 
XP 514: Thermal Electron Bernstein Wave Conversion to O-Mode at GHz G. Taylor, P. Efthimion, J. Wilgen, J. Caughman Goals for this experiment: –Measure.
51st Annual Meeting of the Division of Plasma Physics, November 2 - 6, 2009, Atlanta, Georgia ∆I BS = 170 Amps J BS e-root J BS i-root Multiple ambipolar.
Plasma Turbulence in the HSX Stellarator Experiment and Probes C. Lechte, W. Guttenfelder, K. Likin, J.N. Talmadge, D.T. Anderson HSX Plasma Laboratory,
First Thomson Scattering Results on HSX K. Zhai, F.S.B. Anderson, and D.T. Anderson HSX Plasma Laboratory, U. of Wisconsin, Madison 1. Abstract 5. Summary.
Measurement of Electron Density Profile and Fluctuations on HSX C. Deng, D.L. Brower, W.X. Ding Electrical Engineering Department University of California,
Effects of Symmetry-Breaking on Plasma Formation and Stored Energy in HSX Presented by D.T. Anderson for the HSX Team University of Wisconsin-Madison 2001.
54th Annual Meeting of the APS Division of Plasma Physics, October 29 – November 2, 2012, Providence, Rhode Island 3-D Plasma Equilibrium Reconstruction.
Electron Cyclotron Heating in the Helically Symmetric Experiment J.N. Talmadge, K.M. Likin, A. Abdou, A. Almagri, D.T. Anderson, F.S.B. Anderson, J. Canik,
Hard X-rays from Superthermal Electrons in the HSX Stellarator Preliminary Examination for Ali E. Abdou Student at the Department of Engineering Physics.
= 2·10 18 m -3 T e (0) = 0.4 keV ECH and ECE on HSX Stellarator K.M.Likin, A.F.Almagri, D.T.Anderson, F.S.B.Anderson, C.Deng 1, C.W.Domier 2, R.W.Harvey.
56 th Annual Meeting of the Division of Plasma Physics. October 27-31, New Orleans, LA Using the single reservoir model [3], shown on right, to:
54 th APS-DPP Annual Meeting, October 29 - November 2, 2012, Providence, RI Study of ICRH and Ion Confinement in the HSX Stellarator K. M. Likin, S. Murakami.
C. Deng and D.L. Brower University of California, Los Angeles J. Canik, D.T. Anderson, F.S.B. Anderson and the HSX Group University of Wisconsin-Madison.
Profiles of density fluctuations in frequency range of (20-110)kHz Core density fluctuations Parallel flow measured by CHERS Core Density Fluctuations.
54th Annual Meeting of the Division of Plasma Physics, October 29 – November 2, 2012, Providence, Rhode Island 5-pin Langmuir probe measures floating potential.
48th Annual Meeting of the Division of Plasma Physics, October 30 – November 3, 2006, Philadelphia, Pennsylvania Energetic-Electron-Driven Alfvénic Modes.
Date of download: 7/5/2016 Copyright © 2016 SPIE. All rights reserved. Basic principle of the proposed circuit. The lower portion of the figure contains.
48th Annual Meeting of the Division of Plasma Physics, October 30 – November 3, 2006, Philadelphia, Pennsylvania HIBP Designs for Measurement of the Electric.
Progress on Excel-based Numerical Integration Calculation
Neoclassical Predictions of ‘Electron Root’ Plasmas at HSX
ECE Diagnostic on the HSX Stellarator
Development of X-band 50MW klystron in BVERI
0.5 T and 1.0 T ECH Plasmas in HSX
Reduction of Neoclassical Transport and Observation of a Fast Electron Driven Instability with Quasisymmetry in HSX J.M. Canik1, D.L. Brower2, C. Deng2,
Turbulence associated with the control of internal transport barriers
15TH WORKSHOP ON MHD STABILITY CONTROL
S. P. Gerhardt, A. Abdou, A. F. Almagri, D. T. Anderson, F. S. B
Characteristics of Edge Turbulence in HSX
Overview of Recent Results from HSX
First Experiments Testing the Working Hypothesis in HSX:
Investigation of triggering mechanisms for internal transport barriers in Alcator C-Mod K. Zhurovich C. Fiore, D. Ernst, P. Bonoli, M. Greenwald, A. Hubbard,
Presentation transcript:

47th Annual Meeting of the Division of Plasma Physics, October 24-28, 2005, Denver, Colorado ECE spectrum of HSX plasma at 0.5 T K.M.Likin, H.J.Lu, D.T.Anderson, F.S.B.Anderson, J.M.Canik, C.Deng 1, C.W.Domier 2, R.W.Harvey 3, J.N.Talmadge, K.Zhai HSX Plasma Laboratory, University of Wisconsin, Madison, WI, USA; 1 UCLA, CA, USA; 2 UC, Davis, CA, USA; 3 CompX, Del Mar, CA, USA The spectrum of the Electron Cyclotron Emission (ECE) from HSX is measured with an eight channel radiometer at a magnetic field of 0.5 T The central region of the plasma is not accessible because the plasma is heated by the extraordinary wave at the second harmonic 60 dB stop-band filter at 28±0.3 GHz is used to suppress the non-absorbed microwave power A low-pass filter with 40 dB attenuation in the band of (50-95) GHz reduces pick-up from the heating source at its second harmonic Mod B Vacuum Vessel Flux Surfaces Z, m R, m Horn Antenna Waveguide Line Quartz Window 1.1 HSX Cut 1.2 Block diagram 1. ECE Radiometer 2. Calibration 2.1 Lay-out on the bench Network analyzer is used as a microwave source in CW regime The frequency is fixed within the band width of each channel 2.3 Integrated Response The integrated response has been calculated assuming that the plasma is a black body. In these calculations an etendue of the horn antenna is estimated to be 5.84 cm 2 *sterad The central frequency has been calculated based upon the measured sensitivity of each channel Coeff. (keV / V) Frequency (GHz) Low Field Side High Field Side Frequency (GHz) S (V /  W) 2.2 Measured Sensitivity of the Channels Calibration has been made for two sets of eight IF filters --- one set is for receiving the electron cyclotron emission from the low magnetic field side and the other one – from the high magnetic field side Sensitivity of each channel has been measured at different input power, i.e. at 2.5  W, 5  W, 7.5  W, 10  W and 15  W, so that the output signal varies from 0.5 V up to about 5 V, respectively Sensitivity has been measured at various frequencies within the band width of IF filters Low Field Side High Field Side 20 dB Directional Coupler has been calibrated with a network analyzer, i.e. transmission is measured into the forward and arm sections 8-way power divider followed by IF filters have been calibrated with a network analyzer separately for each channel, i.e. a transmission coefficient is measured in 1 GHz frequency intervals within the corresponding frequency band Frequency (GHz) Power (dB) Directional Coupler Low frequency (< 70 kHz), narrow bandwidth (< 5 kHz), low amplitude (less than 5%) fluctuations have been measured by the ECE radiometer in QHS 3.3 Plasma Density Fluctuations Frequency (kHz) Power Spectrum Density P (a.u.) Frequency (kHz) P (a.u.) ∙10 12 (cm -3 ) F (kHz) Frequency vs. N e Channel Number Low N e High N e Relative Amp. (%) Channel Number Relative Amp. (%) The phase difference between ECE signals on the either side of the magnetic axis is about 180 degrees The frequency decreases with plasma density. See the HSX posters by C.Deng & S.Oh Amplitude is almost independent of the plasma density 3. Results of measurements 3.1 ECE vs. Thomson Scattering ECE channels have been also calibrated against the electron temperature measured by Thomson scattering (TS) diagnostic in the plasma with off-axis heating In order to minimize a contribution from high energetic electrons to the ECE signals, the resonance is located inboard at r/a p = in case of the down-shifted (DWS) frequency channels while the outboard heating is made at r/a p = for the up-shifted (UPS) channels, respectively r/a p = -0.2 r/a p = +0.2 r/a p n e ∙10 18 (m -3 ) Plasma Density r/a p = -0.2 r/a p = +0.2 r/a p T e (eV) Electron Temperature ECE Spectrum Frequency (GHz) T ece (keV) TS and ECE data are averaged over 5 shots Optical depth is calculated based on the TS profiles ECE temperature is corrected on the calculated optical depth 3.2 ECE Spectra in QHS and Mirror configurations n e ∙10 18 (m -3 ) N e in Mirror, CR r/a p UPS Channels DWS Channels T e in Mirror, CR r/a p Te (eV) UPS Channels DWS Channels r/a p n e ∙10 18 (m -3 ) N e in QHS, CR UPS Channels DWS Channels r/a p Te (eV) UPS Channels DWS Channels T e in QHS, CR TS and ECE data are shown in the quasi-helically symmetric (QHS) and 10% Mirror magnetic configurations in the case of the central resonance (CR) heating Plotted ECE data are based on the calibration presented above ECE temperature at UPS frequencies is almost the same in QHS and Mirror while there is a clear difference at DWS frequencies between the two configurations Measured ECE Spectrum Frequency (GHz Mirror QHS T ece (keV) FgFg Higher ECE temperature in the Mirror mode is due to a lower central plasma density in Mirror as compared to QHS 4. Bi-Maxwellian plasma model 5. CQL3D code 5.1 Maxwellian Electron Distribution Function 5.2 Non-Maxwellian Distribution Function CQL3D code is used to simulate the electron cyclotron heating in QHS and to calculate a radiation intensity at the second harmonic of  ce On the left figures the results of two runs are shown The plasma parameters are as follows: central T e = 0.4 keV, central N e = 1∙10 18 m -3 and input power is 100 kW On the left bottom figure it is clearly seen that the ECE temperature for the non- Maxwellian electron distribution function is above 4 keV Further work should be done to understand why CQL3D predicts low ECH absorption in HSX plasmas Solution of the radiation transport equation is used to find a population and a temperature for energetic electrons Bulk plasma density and electron temperature are from TS The best fit is for the following parameters: N tail = 0.1∙10 18 m -3 in QHS, 0.2∙10 18 m -3 in Mirror and T tail = 2.5 keV for both modes 4.1 QHS Spectrum Frequency (GHz) T ece (keV) ECE Data 4.2 Mirror Spectrum Frequency (GHz) T ece (keV) ECE Data