FONT Meeting1 3-BPM resolution with digital filtering N. Blaskovic
Contents 3-BPM resolution using –Single-sample point & averaging –Fitting & transfer matrices –Raw unfiltered data & 25 MHz digital LPF FONT Meeting2N. Blaskovic
Data Data from 12 June 2015 (first shift with high β optics for 3-BPM resolution studies) No 714 MHz or C-band BPFs Charge: 0.7 x FONT Meeting3N. Blaskovic
No filtering Single-sample resolution –~90 nm by fitting –~100 nm using transfer matrices Multi-point averaging (not integration!) resolution –~50 nm by fitting –~50 nm using transfer matrices FONT Meeting4N. Blaskovic
FONT Meeting5N. Blaskovic
FONT Meeting6N. Blaskovic
25 MHz digital LPF Single-sample resolution better than without digital LPF (except IPC with fitting) Multi-point averaging resolution worse than with digital LPF IPC resolution worse than that of IPA and IPB (when fitting) FONT Meeting7N. Blaskovic
FONT Meeting8N. Blaskovic
FONT Meeting9N. Blaskovic
3-BPM resolution FONT Meeting10N. Blaskovic BPM Resolution (nm) Unfiltered25 MHz digital LPF FittingGeometricFittingGeometric PointAve.PointAve.PointAve.PointAve. IPA IPB IPC