UGM 2016 PRAGUE Complete saloon + air duct + HVAC unit modeling with Star- ccm+ Huu-Thi DO 08/03/2016.

Slides:



Advertisements
Similar presentations
Chapter 3. HVAC Delivery Systems
Advertisements

TESTING AND BALANCING IN HEALTHCARE FACILITIES. What is Test & Balance The art of establishing air and water flows to meet design criteria. Total System.
Introduction to Plasma-Surface Interactions Lecture 6 Divertors.
Have you ever held a wire that has current flowing through it? If so what did you notice about it? The wire gets hot. The increase in temperature causes.
Coupling a Network HVAC Model to a Computational Fluid Dynamics Model Using Large Eddy Simulation Jason Floyd Hughes Associates, Inc Fire + Evacuation.
737 PNEUMATICS MENU PRINCIPAL.
Advanced Thermodynamics Note 6 Applications of Thermodynamics to Flow Processes Lecturer: 郭修伯.
Simple and Effective Work Roll Cooling Modification for Hot Mills
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Reliability Prediction of a Return Thermal Expansion Joint O. Habahbeh*, D. Aidun**, P. Marzocca** * Mechatronics Engineering Dept., University of Jordan,
Assurance, Attestation, and Internal Auditing Services
HPC Impacts Automotive Aerodynamics Computational Fluid Dynamics HPC demands Kevin Golsch Aerodynamics – Energy Center 1 October 2010.
Industrial Ventilation - A major control measure Dr. AA, UTM.
Design and Fabrication of a Miniature Turbine for Power Generation on Micro Air Vehicles Team Arman Altincatal Srujan Behuria Carl Crawford Dan Holt.
CHAPTER 4 The First Law of Thermodynamics – Steady flow systems (steady means no change with time)
High-Performance Building Design Presented By: Hend Mohamed Ibrahim By:Ross A. Leventhal May 2001.
Energy Environment & Sustainable Development Thematic Network on Energy in the Built Environment Thematic group 5 : Building Components (including windows.
Vestas.com Condition Based Maintenance of Vestas Offshore Turbines European Offshore Wind Conference & Exhibition 2009, Stockholm Jacob Juhl Christensen,
Design of Heat Sinks P M V Subbarao Mechanical Engineering Department IIT Delhi Success Based on Cooling Challenges …….
Thermal Analysis and Design of Cooling Towers
Cooling design of the frequency converter for a wind power station
Ventilation for Low Energy Buildings
CFD team supports CERN development 19 May M.Battistin CERN May 19 th 2011 C omputational F luid D ynamics team C omputational F luid D ynamics team.
Alstom Wind Madrid, 20 th May 2010 Félix Urrea, VP Operations EMEA.
STEADY HEAT TRANSFER AND THERMAL RESISTANCE NETWORKS
TECHNICAL AND ENVIRONMENTAL IMPROVEMENT OF LNG CARRIER’S PROPULSION MACHINERY USING JATROPHA BIAO DIESEL FUEL 1 Prof. M. A. Mosaad Naval Architecture and.
ME 414 : Project 1 Heating System for NASA North Pole Project Team Members Alan Benedict Jeffrey Jones Laura O’Hair Aaron Randall May 5, 2006.
© 2012 Autodesk Taking Advantage of BIM for CFD Modeling MP3397-P Aryn Bergman Jun Ortega Energy Analyst, TL Circle; BIM Manager, FacebookApplications.
Workshop 4 Flow Through Porous Media
The Use of Computational Fluid Dynamics (CFD) in Achieving Energy Reductions in New Zealand’s Industrial Energy Consumption Energy Research Group Department.
An evaluation of HotSpot-3.0 block-based temperature model
Two-Dimensional Conduction: Finite-Difference Equations and Solutions
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 28/7/2009 Already presented by C. Martel/ J Inigo Golfin on15 th October 2008 CLIC WORKSHOP.
Chapter 4 Control Volume Analysis Using Energy. Learning Outcomes ►Distinguish between steady-state and transient analysis, ►Distinguishing between mass.
Daudi Mushamalirwa Luanda June, 2014 Technical issues of the stability of small size electric systems composed of wind generators and conventional generating.
One-Dimensional Steady-State Conduction
17-9 June 2003Inverse Problem in engineering Symposium Topic FOULING PROBE DEVELOPMENT FOR TUBULAR HEAT EXCHANGERS: A first step Laetitia PEREZ P. TOCHON.
Convection: Internal Flow ( )
Interior Of DMRC Rolling Stock by S.S.Joshi ED/Rolling Stock
Post combustion capture of CO 2 Nick Otter International Workshop on “Power Generation with CCS in India” Ashok Hotel, New Delhi, India 22 nd January 2008.
M. Gomez Marzoa1 13th December 2012 PSB-Dump: first CFD simulations Enrico DA RIVA Manuel GOMEZ MARZOA 13 th December 2012.
PRESENTATION OF CFD ACTIVITIES IN CV GROUP Daniel Gasser.
Oracle Fusion Applications 11gR1 ( ) Functional Overview (L2) Manage Inbound Logistics (L3) Inspect Material.
Objectives Analyze Rotary Heat Exchangers
Conference on PDE Methods in Applied Mathematics and Image Processing, Sunny Beach, Bulgaria, 2004 NUMERICAL APPROACH IN SOLVING THE PDE FOR PARTICULAR.
Modelling of the blowing stage of the glass container forming process Christina G. Giannopapa.
Distributed Resistances and Fan Models Chapter 4.
Objectives Learn about Fans Discuss: Exam (I will have an extra office hour on Monday at 8:00 am) Final Project (I need your group member lists till tomorrow).
E. Da Riva/M. Gomez Marzoa1 WG4 Meeting - 27th June 2012 Air Cooling by means of carbon fiber structure Enrico DA RIVA (EN-CV-PJ) Manuel GOMEZ MARZOA (EN-CV-PJ)
Evaluation of a rate form of the equation of state L.H. Fick, P.G. Rousseau, C.G. du Toit North-West University Energy Postgraduate Conference 2013.
Risto Nousiainen, CLIC workshop ” Technical Issues, Integration & Cost ” working group Progress on Study of Module Cooling Risto Nousiainen.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Ventilation for buildings - Calculation methods for the determination.
COOLING & VENTILATION PLANTS M. Nonis – CERN EN Department / CV Group Annual Meeting of the FCC study – Rome 14 th April 2016.
Pathway to Low Emission Power Generation using Fossil Fuels : an EU Technology Perspective Nick Otter International Workshop on “Power Generation with.
Copyright © 2012, Oracle and/or its affiliates. All rights reserved. Oracle Proprietary and Confidential. 1.
Chapter 6 technology institute of HAVC from usst INDUSTRIAL VENTILATION TUTORIAL 王丽慧.
MENU PRINCIPAL. THIS PRESENTATION INCLUDES THE SOURCES OF AIR, THE MAJOR SYSTEM COMPONENTS AND THE WAY THE CONTROLS AND INDICATORS ARE USED TO OPERATE.
ASX Spotlight Investor Conference 30 May 2017 in Singapore
Integrating Modeling and Physical Testing for Assessing Filtered Exhaust Stack Sampling Probe Location Xiao-Ying Yu, Kurtis P. Recknagle, John A. Glissmeyer,
Innovative He cycle Francois Millet.
CEDAR Detector Ventilation System Review
Chapter 18 MobileApp Design
Objectives Finish with Exchangers - Start Air Distribution Systems
Objectives Learn about Fans Discuss Exam Final Project.
Objectives Finish with Exchangers - Start Air Distribution Systems
Cooling aspects for Nb3Sn Inner Triplet quadrupoles and D1
FBE03: Building Construction & Science
Thermal behavior of the LHCb PS VFE Board
Ventilation Air moves down a pressure gradient Low High pressure
41st Gas-Lift Workshop Houston, Texas, USA June 3 - 7, 2019
Presentation transcript:

UGM 2016 PRAGUE Complete saloon + air duct + HVAC unit modeling with Star- ccm+ Huu-Thi DO 08/03/2016

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 2 1. Presentation of Alstom p 3 2. Introductionp 5 3. Step 1: Saloon thermal comfort and air duct designp 7 4. Step 2: Hvac unit fan MRF modeling calibrationp Step 3: Complete modelp Step 4: Testing preparation by CFD p Conclusionp 20

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 3 Presentation of Alstom  Trains  Infrastructures  Signalling  Services  Turnkey systems

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 4 Presentation of Alstom / Rolling Stock from Tramways to Very High Speed Trains DISTANCE Very High Speed High Speed SPEED Tramwa y

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 5 Introduction Main lines European Normes criteria for climatic comfort air temperature in a saloon are severe ( thermal gradient < 3K in an section of the saloon volume) Requirements to achieve the performance Good HVAC behaviour (at nominal point) Good air ventilation in the saloon Context: a new saloon interior design on an existing train

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 6 Challenge and Approach Challenge New interior for the « bar » saloon But same HVAC unit and air duct architecture The current HVAC unit has reached at its pressure drop limit The air duct shapes must be optimised to respect the pressure drop limit No mock-up => no mistake is allowed Approach Step 1: thermal comfort design and standard air duct design to reduce pressure drop Step 2: Hvac unit Moving Reference Frame modeling Step 3: Complete model for a more accurate air flow volume rate Step 4: Preparation of testing by CFD assistance

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 7 Step 1: thermal comfort and air duct design Saloon geometry Large 3D saloon model (length > 10m) Only saloon and air duct network study xm side Air duct network Hvac unit position yp side Air duct network > 10 m

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 8 Step 1 Saloon thermal comfort design After iterations on air diffusion The thermal gradient is quite good Cooling mode: Text=40°C 1K Good mixing behaviour 2 nd order discretisation Ideal gas Steady-state K-Epsilon Realizable

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 9 Step 1 Air duct design Example of air duct optimisation Pressure drop 40 Pa improvement Initial design Improved design Pressure drop optimisation performed but uncertainties remain on the air flow volume rate delivered by the Hvac unit the future train => a more accurate modeling: Moving Reference Frame modeling of the Hvac unit fan

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 10 Step 2 HVAC unit by Moving Reference Frame (MRF) calibration of the hvac unit fan modeling New Air 2: AN_xp Diffusion xm : AS_xm Diffusion xp : AS_xp Recycling : AR Heat exchanger Thermal resistances Fan New Air 1: AN_xp

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 11 Step 2 HVAC unit by Moving Reference Frame (MRF) calibration of the hvac unit fan modeling / mesh views About 13M cells polyedral Trimmed cells

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 12 Step 2 HVAC unit by Moving Reference Frame (MRF) calibration of the hvac unit fan modeling / testing Moving Reference Frame CFD approach is enough accurate in this case The air flow volume rate / pressure drop curve is well reproduced (regarding testing uncertainties) The HVAC unit fan modeling is representative 2 nd order discretisation Incompressible Steady-state K-Epsilon Realizable MRF ∆P(Pa) Qv(m3/h)

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 13 Step 2 HVAC unit modeling / mesh cell number reduction heat exchanger by porous media Light polyedral mesh for an exchanger about 3 M cells 0,2 mm thins !!! Trimmed cell mesh with porous media < 0,5 M cells

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 14 Step 2: HVAC unit modeling / mesh cell number reduction heat exchanger by porous media Estimation of Pi and Pv porous media coefficients with several pressure drop points The porous media modeling reproduces well the equivalent pressure drop for the exchanger V(m/s) Pi, Pv porous media Y= A x 2 + B x + C V(m/s) ∆P(Pa)

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 15 Step 2 Hvac unit by CFD MRF modeling Final optimized modeling The Hvac unit air flow volume dispatching is the same when the pressure drop changes The MRF hvac unit model can be integrated into the saloon + air duct network model Qv (m3/h)

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 16 Step 3: Complete saloon + air duct + hvac unit Geometry & mesh HVAC unit Air duct network Recycling air 44 M cells

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 17 Step 3: Complete saloon + air duct + hvac unit Separation at the interface between air HVAC and the duct Quite stabilized flow 2 nd order discretisation Incompressible Steady-state K-Epsilon Realizable MRF

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 18 Step 3: Complete saloon + air duct + hvac unit Air duct network / flow dispatching Yp_Qv_x2 Ym_Qv_x1 Qv_Ls Yp_Qv_x1 Ym_Qv_x2 Qm_duct_xm Qm_duct_xp = AS_xp Ym_Qv_x3 Qv_AN_xm Qv_AN_xp Slight difference between branches on side xm and xp side regarding to the initial HVAC distribution hypothesis (50% / 50%) Qv (m3/h) The complete model results are quite similar to the model without HVAC => the previous air flow volume rate balancing hypothesis in air duct design phase were quite realistic xm side xp side

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 19 Step 4: Testing preparation by deflector position tunning Deflector has been turned of -10° Only slight tunning capabilities on the testing (confirmed in real life) Deftector at angle 0° Deflector at angle -10°

© ALSTOM SA, All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authorisation, is strictly prohibited ALSTOM – Global Conference 2016 Prague - Huu-Thi DO – 08/03/2016– P 20 Conclusion All the design has been performed by CFD with Star-ccm+ Almost performances and limitations have been identified at very early project stage Final testing on real train has confirmed the CFD results Thanks to CFD approach that permitted to reach globally the thermal comfort performances without the expensive cost of a real saloon mock-up