PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004.

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

CERN Mar Luminosity and longitudinal density W.C. Turner 1 Luminosity optimization and longitudinal density instrumentation W.C. Turner LBNL.
Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
IHEP,Protvino,Russia 1 Current status of a gas luminosity monitor Sergei Erin † † For the LCAL group V.Bezzubov,S.Erin, A.Ferapontov, Yu.Gilitsky,V.Korablev,
CMS Calorimetry in the Very Forward Direction E. Norbeck, P. Debbins, and Y. Onel University of Iowa For the 23 rd Winter Workshop on Nuclear Dynamics.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
The performance of LHCf calorimeter was tested at CERN SPS in For electron of GeV, the energy resolution is < 5% and the position resolution.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
F.Brinker, DESY, July 17 st 2008 Injection to Doris and Petra Fitting the detector in the IP-region Radiation issues Beam optic, Target cell Polarisation.
Far forward angle physics at the LHC E. Norbeck and Y. Onel University of Iowa For the 24th Winter Workshop on Nuclear Dynamics South Padre Island
M.Gallinaro, ``Innovative Particle and Radiation Detectors’’, Siena, October slide 1 The CDF MiniPlug Calorimeter Forward Physics Conceptual.
ALPHA Storage Ring Indiana University Xiaoying Pang.
E. Norbeck U. IowaFast Gas Detector APR 05 Tampa1 Small Fast Gas Detector for High-Energy Electrons E. Norbeck, J.E. Olson, and Y. Onel University of Iowa.
Rad Hard Active Media for Calorimeters E. Norbeck, J.E. Olson, A. Moeller, and Y. Onel University of Iowa PPAC Čerenkov Liquid with Tungsten metal.
Energy Resolution of a Parallel- Plate-Avalanche-Chamber Kausteya Roy Professors E. Norbeck and Y. Onel.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
Roberto GemmeIII Convegno Nazionale sulla Fisica di ALICE Frascati, 12-14/11/2007 Reaction plane determination with the neutron Zero Degree Calorimeters.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
Jornadas LIP 2008 – Pedro Ramalhete. 17 m hadron absorber vertex region 8 MWPCs 4 trigger hodoscopes toroidal magnet dipole magnet hadron absorber targets.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
IPM status and plans 1.Yellow vertical detector has extremely low coupling to beam and to signal-gating grid. It also has improved resolution due to reduced.
H. Matis, M. Placidi, A. Ratti, W. Turner [+ several students including S. Hedges] (LBNL) E. Bravin (CERN), R. Miyamoto (BNL – now at ESSS) H. Matis -
PHENIX Local Polarimeter PSTP 2007 at BNL September 11, 2007 Yuji Goto (RIKEN/RBRC)
Ionization Detectors Basic operation
Anders Kirleis Stony Brook University The Design Of A Detector For The Electron Ion Collider.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
CALICE 03/14/05Ed Norbeck U. of Iowa1 PPACs in a Calorimeter Edwin Norbeck University of Iowa.
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
Luminosity Monitoring Issues  ZDC  what’s the advantage?  problems  BBC  can they do it? A. Drees QCD critical point workshop, Mar
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
1 ZDCs in CMS Michael Murray,U Kansas pp Lum EMHad PMTs Lead/ plastic Fiber 1.5cm tungsten plates 2mm plates Beam LED Spare space for flow upgrade Light.
( ATLAS was designed for LHC: L=10 34 cm -2 s -1 ) [ Now we expect 7.5 x instantaneous and 10 x integrated luminosity ] PILEUP: from ~30  >200 proton.
SEM SIC SEM SIC 2 SEMs & 2 SICs closed to the Dumps 1 SIC, 1 Faraday cup & 1 SEM SEM SIC F. cup 4 similar set-ups : Girder 6,7,11 and 13 4 th – 8 th October.
Inclusive cross section and single transverse-spin asymmetry of very forward neutron production at PHENIX Spin2012 in Dubna September 17 th, 2012 Yuji.
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
ATLAS and the Trigger System The ATLAS (A Toroidal LHC ApparatuS) Experiment [1] is one of the four major experiments operating at the Large Hadron Collider.
H. Matis, S. Hedges, M. Placidi, A. Ratti, W. Turner [+several students] (LBNL) R. Miyamoto (now at ESSS) H. Matis - LARP CM18 - May 8, Fluka Modeling.
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
E.B. Holzer BLM Meeting: Q & A March 20, Questions and Answers.
1 Status of Zero Degree Calorimeter for CMS Experiment O.Grachov, M.Murray University of Kansas, Lawrence, KS A.S.Ayan, P.Debbins, E.Norbeck, Y.Onel University.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
E+/e- Backgrounds at BEPCII/BESIII JIN Dapeng Aug. 22, 2011.
Rapidity gaps in Heavy Ions Collisions at RHIC and the LHC Features of Heavy Ion collisions forward detectors at RHIC and LHC Ultra-Peripheral Collisions.
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
Integration of forward physics detectors into the LSS of the LHC D. Macina (TS/LEA) Technical Support 2004 Workshop.
PPAC Parallel Plate Avalanche Counter Edwin Norbeck University of Iowa For meeting at SLAC June 2, 2004.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
Ilhan TAPAN* and Fatma KOCAK
Budker INP V.Aulchenko1,2, L.Shekhtman1,2, V.Zhulanov1,2
Status of Zero Degree Calorimeter for CMS Experiment
The ATLAS Zero Degree Calorimeter Brookhaven National Laboratory, USA
Recent DHCAL Developments
HE Calorimeter Upgrade Studies
CASA Collider Design Review Retreat Other Electron-Ion Colliders: eRHIC, ENC & LHeC Yuhong Zhang February 24, 2010.
LHC (SSC) Byung Yunn CASA.
Luminosity measurement at LHC (The machine point of view)
Luminometer Integration at IR2
The Measurement of Forward Particle Production in LHC
Update on Ecal simulation
Presentation transcript:

PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004

Nov. 5, 2004PPAC E. Norbeck U. Iowa2 Example of low-pressure PPAC (Parallel Plate Avalanche Counter) Two flat plates Separated by 1 mm Filled with 80 torr isobutane 1000 V between plates Operates in avalanche mode MIPs often leave no signal Showers give large signal directly into 50 Ω

Nov. 5, 2004PPAC E. Norbeck U. Iowa3 PPAC in Zero Degree Calorimeter Three flat plates, separated by 2 mm Middle plate at high voltage Outer plates hold atmospheric pressure Gas flows in one side and out the other Plates can be made of heavy metal (W alloy) so as to be part of the absorber. Beam In

Nov. 5, 2004PPAC E. Norbeck U. Iowa4 Radiation damage Parts of the ZDC will receive huge amounts of radiation, ~100 Grad. A PPAC can be entirely metal and ceramic so that it will not be damaged by 100 Grad. With PPACs the ZDC will not need to be removed during the life of the LHC.

Nov. 5, 2004PPAC E. Norbeck U. Iowa5 Individual PPACs can be replaced if necessary Rigid coax and gas lines extend to top of TAN No organic materials in high-radiation region Beam In

Nov. 5, 2004PPAC E. Norbeck U. Iowa6 Beam In Zero Degree Calorimeter The green is solid metal (W). Detectors that sample the shower are shown in blue. Detector near front end is for EM shower

Nov. 5, 2004PPAC E. Norbeck U. Iowa7 First PPAC provides trigger and horizontal position information. The other PPACs would not be divided horizontally. 6 HV plates in the first PPAC Beam In

Nov. 5, 2004PPAC E. Norbeck U. Iowa8 1.8 ns 50 torr 790 V 7 mv into 50  Fast signals can provide timing for trigger Single peak with considerable noise. The noise is large because of the small size of the signal using our 137 Cs source. With the much larger signals from high-energy showers, the noise will be negligible.

Nov. 5, 2004PPAC E. Norbeck U. Iowa9 ZDC signal vs impact parameter With heavy ions, impact parameter is related to neutron multiplicity (proportional to total energy deposited in ZDC)

Nov. 5, 2004PPAC E. Norbeck U. Iowa10 In All of the PPACs except the first would be used to measure the neutron multiplicity and/or luminosity

Nov. 5, 2004PPAC E. Norbeck U. Iowa11 PPAC ion signal Fast electron signal is followed by a small, slow (500 ns) signal from ions moving between the plates. The slow ion signal is easily removed. To measure time averaged luminosity the total current can be integrated over several  s.

Nov. 5, 2004PPAC E. Norbeck U. Iowa12 Ion collection time (1 mm spacing) 0.3  s 0.5  s 50 torr 790 V

Nov. 5, 2004PPAC E. Norbeck U. Iowa13 Beam An ion chamber could be added to measure the average luminosity Ion Chamber

Nov. 5, 2004PPAC E. Norbeck U. Iowa14 Four quadrants Beryllium-copper plates Ceramic and sapphire insulators Plated strip on ceramic circuit board plate bias connections Isolated instrumentation ground and local ground shielding enclosures Ionization Chamber W.C. Turner et al., NIM A 461 (2001) 107

Nov. 5, 2004PPAC E. Norbeck U. Iowa15 S.N.White NIM A 417 (1998) 1 Absolute luminosity for PbPb Use correlated forward-backward neutrons. Cuts out beam-air and beam-wall collisions.  1n,1n =.535 b  1n,xn = 1.89 b  xn,xn = 14.8 b

Nov. 5, 2004PPAC E. Norbeck U. Iowa16 Double PPAC One side could be used for fast signals and the other for integrated luminosity. Two independent PPACs in the same gas volume.

Nov. 5, 2004PPAC E. Norbeck U. Iowa17 PPAC energy resolution Poor for single, low-energy heavy ion Current per  m   is huge! Same size signal from shower has good energy resolution. Measure resolution with double PPAC Look at ratio between two sides

Nov. 5, 2004PPAC E. Norbeck U. Iowa18 Double PPAC for testing energy resolution

Nov. 5, 2004PPAC E. Norbeck U. Iowa19 Ion and electron signals with 2 mm spacing 168 pF 1.6  s 6.2ns 1.3  s Amplified signal using gamma source. Positive overshoot is from amplifier. Ion collection time is three times as long with the 1 mm spacing.

Nov. 5, 2004PPAC E. Norbeck U. Iowa20 For high speed, the RC time constant must be kept small. Only PPACs of small area are fast, ~1 ns The segments in the segmented PPAC of slide 5 are small enough to be fast. R = 50 Ω (coax cable). C is the capacity between the plates C =.885 pF for 1 mm gap and area of 1 cm 2 For our larger PPAC with C = 168 pF rise time ~5 ns fall time ~7 ns Fast enough for the Zero Degree Calorimeter where minimum beam crossing time is 25 ns.

Nov. 5, 2004PPAC E. Norbeck U. Iowa21 Tests with double PPAC Test with EM showers using 80 ps bunches of 7 GeV electrons from the Advanced Photon Source, at Argonne National Laboratory Test with low energy hadron showers using the 120 GeV proton test beam at Fermilab

Nov. 5, 2004PPAC E. Norbeck U. Iowa22 PPAC Test at ANL IOWA double PPAC was tested for energy resolution with electron showers from the Advanced Photon Source (APS) at Argonne National Laboratory. The booster ring of the APS puts out 76 ps bunches of 7 GeV positrons at the rate of two per second, with 3.6 x positrons in each bunch. In normal operation the positrons are injected into the main storage ring where they are used to produce synchrotron radiation. There are maintenance and development periods during which the beam is directed into a beam dump. We set up our equipment next to the beam line just in front the beam dump. The entire beam bunch has an energy of 2.5 x eV, or 2.5 x 10 8 TeV, much more than we needed. The PPAC was close to the beam line and so was exposed to showers generated by the outer halo of the beam striking the beam pipe. Because of the small angle between the positrons and the wall of the beam pipe, the wall acted as an absorber with a thickness of several centimeters. The showers were developed in this absorber.

Nov. 5, 2004PPAC E. Norbeck U. Iowa23 Energy Resolution Data of PPAC Test at ANL Ratio E front to E back is constant to within ± 2%

Nov. 5, 2004PPAC E. Norbeck U. Iowa GeV proton test Measured signal size (into 50 Ω, no amplification) at shower maximum. Maximum signal from detector placed after 30 cm of iron was 17 mV TeV hadrons showering in tungsten would give a much larger signal.

Nov. 5, 2004PPAC E. Norbeck U. Iowa25 No “Texas tower effect” With above-atmosphere hydrocarbon gas occasional proton from n-p scattering gives huge signal. In PPAC, proton hits wall at almost full energy. PPAC signal mostly from low-energy electrons. We will test this with detailed simulations.

Nov. 5, 2004PPAC E. Norbeck U. Iowa26 CONCLUSIONS PPACs in a ZDC Can be made radiation hard. Can provide transverse position information. Have good energy resolution. Have sub nanosecond time resolution. Can be integrated to give average luminosity. Can be replaced without removing the ZDC. ZDC can be left in place for both pp and PbPb