Laser Alignment System for LumiCal and BeamCal Arkadiusz Moszczyński, Wojciech Wierba, Leszek Zawiejski Institute of Nuclear Physics PAN, Cracow 22nd FCAL.

Slides:



Advertisements
Similar presentations
Beam test of novel ASICs and sensors Marcin Chrząszcz Cracow University of Technology Itamar Levy Tel Aviv University.
Advertisements

February 12-13, 2006FCAL Collaboration Meeting INP PAN, Kraków, Poland 1 LumiCal displacement measurement present status Wojciech Wierba INP PAN Jerzy.
Frequency Scanning Interferometry (FSI) measurements
Stephen Gibson, ATLAS Offline Alignment, 2 nd July Incorporating FSI with the Offline Alignment Overview ATLAS Group, University of Oxford Stephen.
S. M. Gibson, IWAA7 November ATLAS Group, University of Oxford, UK S. M. Gibson, P. A. Coe, A. Mitra, D. F. Howell, R. B. Nickerson Geodetic Grids.
March, 11, 2006 LCWS06, Bangalore, India Very Forward Calorimeters readout and machine interface Wojciech Wierba Institute of Nuclear Physics Polish Academy.
AMULET Advanced Metrology Using LasEr Tracers John Dale.
The LiCAS FSI Subsystem Current Status and Initial Measurements John Dale for the LiCAS Collaboration IOP HEP April 2008.
X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker.
ILC roles Interferometry Results 2009 / 2010 Mon 20 Apr :00 JST (01:00 UTC) MDI TILC09 – Tsukuba OXFORD MONALISA 1.
Accelerator and Beam Delivery The LC-ABD (Linear Collider: Accelerator and Beam Delivery) consortium is a group of UK institutes aiming to develop new.
The Linear Collider Alignment and Survey (LiCAS) Project Richard Bingham*, Edward Botcherby*, Paul Coe*, Grzegorz Grzelak*, Ankush Mitra*, Johannes Prenting.
LiCAS Project: FSI Overview Richard Bingham, Edward Botcherby, Paul Coe, John Green, Grzegorz Grzelak, Ankush Mitra, John Nixon, Armin Reichold University.
Initial Calibration and Stability Results from the LiCAS RTRS FSI System John Dale for the LiCAS Collaboration IWAA February 2008.
Final Doublet Stability and in-detector Interferometry MONALISA David Urner Oxford University.
25/06/2015Robert King, Oxford University - Graduate Seminar Series 1 Electronic speckle pattern interferometry at the SLHC.
LumiCal Alignment System Status report Leszek Zawiejski, Tomasz Wojtoń, Arkadiusz Moszczyński Institute of Nuclear Physics PAN, Cracow 25th FCAL Collaboration.
Laser measurement of the LAT detector displacement Jerzy Zachorowski Instytut Fizyki UJ Wojciech Wierba Instytut Fizyki Jądrowej PAN.
1 Laser alignment system Status report Leszek Zawiejski INP PAN, Cracow EUDET Annual Meeting 2008, October 6-8, Amsterdam, Holland W. Wierba, K. Oliwa,
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
Concepts for Combining Different Sensors for CLIC Final Focus Stabilisation David Urner Armin Reichold.
H. MAINAUD DURAND PACMAN WP1 OUTLINE Tasks & role of associated partner Plans for training.
Octobre MPI Munich -energy calibration and resolution (end 2006) -Implementaion in LDC/Mokka (end 2006) -realistic simulation (2007) -background.
MONALISA an Update David Urner Paul Coe Matthew Warden Armin Reichold Monitoring, Alignment & Stabilisation with high Accuracy.
ALCPG Tracking Session 1/11/03 K. Riles - U. Michigan1 Status Report on Michigan Group Tracker Alignment R&D Keith Riles, Jin Yamamoto, Haijun Yang University.
March 2004LCWS Stanford Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Laser positioning system Status Wojciech Wierba, Krzysztof Oliwa, Leszek Zawiejski, Michał Karbowiak (diploma student) Institute of Nuclear Physics.
Frequency Scanned Interferometer Demonstration System Tim Blass, Jason Deibel, Sven Nyberg, Keith Riles, Haijun Yang University of Michigan, Ann Arbor.
Frequency Scanned Interferometer Demonstration System Jason Deibel, Sven Nyberg, Keith Riles, Haijun Yang University of Michigan, Ann Arbor American Linear.
February 13. FCAL Workshop in Cracow W. Lohmann, DESY Bunch charge effects and diff. Bhabha cross section News From Theory and Generator Diamond.
December 4, 2015KILC2012 Daegu Labs involved: Argonne, Vinca Inst, Belgrade, Bukharest IFIN-HH & ISS, CERN, Univ. of Colorado, Cracow AGH-UST, Cracow IFJ-PAN,
Welcome to MONALISA A brief introduction. Who we are... David Urner Paul Coe Matthew Warden Armin Reichold Electronics support from CEG Central Electronics.
Haga clic para modificar el estilo de texto del patrón Infrared transparent detectors Manuel Lozano G. Pellegrini, E. Cabruja, D. Bassignana, CNM (CSIC)
LumiCal mechanical & sensors design Wojciech Wierba J.Błocki, E.Kielar, J.Kotuła, K.Oliwa, L.Zawiejski FCAL Workshop, IFJ PAN Cracow,
Octobre MPI Munich VFCAL Report W. Lohmann, DESY Laser alignment system Infrastructure for sensor diagnostics Sensor test facilities FE design Labs.
The stabilisation of the final focus (StaFF) system Sun 12 th March 2006 MDI – LCWS06 at I I Sc Bangalore David Urner, Paul Coe, Armin Reichold.
Si sensors for LumiCal Wojciech Wierba Institute of Nuclear Physics PAN Cracow, Poland FCAL Workshop, LAL Orsay,
1 Laser alignment system Status report Leszek Zawiejski Eryk Kielar, Krzystof Oliwa, Wojciech Wierba, INP PAN, Cracow, Poland Wojciech Slominski, Jagiellonian.
Integration with LDC & Push-pull impact on LumiCal Wojciech Wierba Institute of Nuclear Physics PAN Cracow, Poland FCAL Workshop, LAL Orsay,
MONALISA David Urner Paul Coe Matthew Warden Armin Reichold Monitoring, Alignment & Stabilisation with high Accuracy.
1 ILD meeting LAL M. Joré – Integration status Matthieu Joré – 25 th of May ILD integration status and open issues.
1 Some results from LumiCal Monte Carlo Studies Michał Karbowiak, B. Pawlik, L. Zawiejski Michał Karbowiak (*), B. Pawlik, L. Zawiejski Institute of Nuclear.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
09:40 – 10:00 (JST) Wed 5 Mar 2008 MONALISA : JAI Oxford MDI ATF2 TILC08 Sendai Japan 1 / 26 MONALISA Laser based alignment and stability monitoring.
December 7, 2005DESY EUDET in FCAL VINCA, Belgrade Univ. of Colorado, Boulder, BNL, Brookhaven, AGH Univ., INP & Jagiell. Univ. Cracow, JINR, Dubna, NCPHEP,
Silicon Sensors for LumiCal Status Wojciech Wierba, J. Błocki, W. Daniluk, E. Kielar, J. Kotuła, A. Moszczyński, K. Oliwa, B. Pawlik, L. Zawiejski Institute.
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
MONALISA Update David Urner ATF2 Meeting Dec
Status of Forward Calorimetry R&D: Report from the FCAL Collaboration Bruce A. Schumm Santa Cruz Institute for Particle Physics University of California,
February 12-13, 2006 FCAL Collaboration Meeting INP PAN, Kraków, Poland Readout electronics for LumiCal – first approach Wojciech Wierba Witold Daniluk.
February 29, 2016LCWS Arlington Labs involved: Argonne, Vinca Inst, Belgrade, Bukharest IFIN-HH & ISS, CERN, Univ. of Colorado, Cracow AGH-UST & IFJ-PAN,
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
Redesign of LumiCal mechanical structure W.Daniluk, E.Kielar, J.Kotula, K.Oliwa, Wojciech Wierba, L.Zawiejski Institute of Nuclear Physics PAN Cracow,
1 ATLAS Muon Spectrometer Alignment LHC Days in Split, 5-9 Oct J.Krstic, M.Milosavljevic Institute of Physics, Belgrade D.Fassouliotis,C.Kourkoumelis,
November, 7, 2006 ECFA06, Valencia, Spain LumiCal & BeamCal readout and DAQ for the Very Forward Region Wojciech Wierba Institute of Nuclear Physics Polish.
Octobre 2007LAL Orsay Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY.
FP420 Hybrid Mechanical Design Ray Thompson / Manchester Manchester Xmas O7 Ray Thompson Julian Freestone, Andy Elvin.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
LumiCal High density compact calorimeter at the ILC Wojciech Wierba Institute of Nuclear Physics PAS Cracow, Poland.
FCAL Takashi Maruyama SLAC SiD Workshop, 15 – 17 November, 2010, Eugene, Oregon.
WP3 Frequency Scanning Interferometry Analysis Techniques for the LiCAS RTRS John Dale.
What’s new at LAL-LLR ( MDI issues) M.Jore, C.Clerc Visit at CMS Forward detectors meeting at LLR Vacuum in Beam pipe, first LAL results.
FCAL R&D towards a prototype of very compact calorimeter
Layout of Detectors for CLIC
Laser positioning system
LumiCal mechanical design, integration with LDC and laser alignment
The 5th HERD Workshop, CERN IsCMOS Camera Developement
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
Conlusions of the Cracow Meeting
Peter Kodyš, Zdeněk Doležal, Jan Brož,
Presentation transcript:

Laser Alignment System for LumiCal and BeamCal Arkadiusz Moszczyński, Wojciech Wierba, Leszek Zawiejski Institute of Nuclear Physics PAN, Cracow 22nd FCAL Workshop, , Cracow

2 ILD : International Large Detector Forward components: QD0 magnets, calorimeters High precision measurements of the physical variables required alignment system (s) for components of ILD, including LumiCal

3 LumiCal alignment Mechanical aspect of LumiCal alignment Good reference points for position measurement of LumiCal can be: QD0 magnet Beam Position Monitors also beam pipe The measurements of the relative distances to QD0 in X,Y and Z directions High accuracy in luminosity measurements at ILC/CLIC (  L/L ~ /10 -2 ) require precisely measurement of the luminosity detector displacements: less than 500  m in X,Y directions, 100  m in Z direction and a few microns for internal silicon sensor layers The measurements of absolute distance between Left and Right LumiCal calorimeters

4 The design of the LAS system The laser alignmet system will contain the main components: - infra-red laser beam and semi-transparent position sensitive detectors (PSDs) - tunable laser(s) working within Frequency Scanning Interferometry (FSI) system FSI – will be used for measurements of the absolute distance between LumiCal calorimeters by measurement of interferometer optical path differences using tunable lasers (by counting the frenges Semi-transparent sensors : LumiCal displacements of the internal Si layers and detectors relative positions A roughly estimation of the size of LAS output data is on the level of hundred kB/s and they will be included into LumiCal DAQ system xxxxxxxxxxxxxxxxxxxxxxxxx

5 Semi-transparent sensors (PSD) Proper shape of signals distributions from cathode and anode strips Quality testing of the sensors: microscope, probe station, and laser beam Cathode strips Anode strips Problem with some of the sensors: no signals from X or Y strips Semi - transparent amorphous silicon strip sensors, DPSD using laser with wavelength above ~ 780 nm, received from Oxford University, High precision (ZEUS MVD) position measurements in two coordinates X / Y : ~10  m 9 high-quality sensors were selected and they will be used to construct a prototype of the positioning system in laboratory

6 VME : launch of the system LynxOS to read data from sensors Towards the laboratory prototype mx =  i x i w i, my =  i y i w i with w i = I i /  I i i =1 … N x i, y i - strip positions, I i - strip signals Roughly position calculations – mean values: mx, my LAB - system prototype with optical movable table 2D Studies on the behaviour of the sensors, laser beam and calculation of the prototype displacements in ref. frame - actual accuracy. or use a Wiener crate VM-USB VME controller with USB2 interface: To read directly data from cards and for integration with DAQ system

7 Alignment system based on Frequency Scanning Interferometry FSI technique enables remote, multiple, simultaneous and precide distance measurements. It uses tunable lasers for measurement of interferometer optical path differences and provides an absolute distance measurements The first step : the tunable laser was purchased to laboratory power 10mW wavelength range: 663 – 678 nm Next step : build in laboratory FSI system prototype (similar to that used for SiD (ATLAS concept)

8 Summary  Accuracy of X, Y position measurement using semi-transparent strip sensors can reach ~10 µm  The readout electronics can be placed outside ILD, but log cables decreases accuracy and consume space  FSI looks very promising – used in many HEP experiments  Accuracy of very simple FSI absolute distance measurement in air can reach ~10-20 µm in X, Y and ~30 µm for Z  More sophisticated FSI methods can give ~100 nm (or better) accuracy  FSI equipment (Tunable Laser - ~10k€, Controller ~5k€, Optics/FO etc. – ~100€/measuring point) is expensive for low amount of measuring points.  The FSI laser beam can be splitted up to ~1000 measuring points.