Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.

Slides:



Advertisements
Similar presentations
Design Studies and Sensor Test for the Beam Calorimeter of the ILC Detector E. Kuznetsova DESY Zeuthen.
Advertisements

17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensors for the ILC forward calorimeter K. Afanaciev, Ch. Grah,
17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensor materials K. Afanaciev on behalf of FCAL collaboration.
17-May-15FCAL collaboration meeting. Krakow.. Radiation hardness of GaAs Sensors K. Afanaciev, Ch. Grah, A. Ignatenko, W. Lange, W. Lohmann, M. Ohlerich.
Radiation Hard Sensors for the BeamCal of the ILC C. Grah FCAL Collaboration 10 th ICATPP Conference, Villa Olmo.
Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.
Investigation of the properties of diamond radiation detectors
Measurements on Single and Poly Crystal CVD Diamond Sensors
Beamdiagnostics by Beamstrahlung Analysis C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
August 2005Snowmass Workshop Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Current Status of Diamond Sensors R&D in Minsk Group FCAL Collaboration Institute of Nuclear Physics PAN February 12-13, 2006, Krakow, Poland.
Radiation Hard Sensors for the Beam Calorimeter of the ILC C. Grah 1, R. Heller 1, H. Henschel 1, W. Lange 1, W. Lohmann 1, M. Ohlerich 1,3, R. Schmidt.
FCAL R&D in Minsk Group: Sensors and Electronics FCAL Collaboration MPI Munich October 17, 2006, Munich, Germany Presented by Igor Emeliantchik.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
1 LumiCal Optimization and Design Takashi Maruyama SLAC SiD Workshop, Boulder, September 18, 2008.
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
Calorimeter technologies for forward region instrumentation K. Afanaciev 2, R. Dollan 1 V. Drugakov 2, C. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
March 2004LCWS Stanford Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Instrumentation of the very forward region of the TESLA detector – summary of the Workshop on Forward Calorimetry and Luminosity Measurement, Zeuthen,
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
2. December 2005Valencia Workshop Very Forward Region Instrumentation Wolfgang Lohmann, DESY Basic functions: - Hermeticity to small polar angles - Fast.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
July 2006ALCWS Vancouver Very Forward Instrumentation of the Linear Collider Detector On behalf of the Wolfgang Lohmann, DESY.
Karsten Büßer Instrumentation of the Forward Region of the TESLA Detector International Europhysics Conference on High Energy Physics Aachen, July 19th.
First results from silicon and diamond sensors K. Afanasiev 1, I. Emeliantchik 1, E. Kouznetsova 2, W. Lohmann 2, W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen.
Fast Beam Diagnostics at the ILC Using the Beam Calorimeter Christian Grah, Desy FCAL Workshop February Cracow.
Novembre 2008LCWS Chicago1 FCAL Report W. Lohmann, DESY Challenges and Design Sensors and Sensor Studies FE ASICS development Data Transfer, Infrastructure.
Octobre MPI Munich VFCAL Report W. Lohmann, DESY Laser alignment system Infrastructure for sensor diagnostics Sensor test facilities FE design Labs.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
February, INP PAN FCAL Workshop in Cracow W. Lohmann, DESY The BCD (Baseline Configuration Document) The next calendar dates Where we are with FCAL.
Investigation of CVD Diamonds as Sensor Material for BeamCal Alexandr Ignatenko FCAL Collaboration Meeting, Orsay October 6-7, 2007.
Electrical features of diamond sensors D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
The Luminosity Calorimeter Iftach Sadeh Tel Aviv University Desy ( On behalf of the FCAL collaboration ) June 11 th 2008.
1 LumiCal Optimization Simulations Iftach Sadeh Tel Aviv University Collaboration High precision design May 6 th 2008.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Albuquerque 1 Wolfgang Lohmann DESY On behalf of the FCAL collaboration Forward Region Instrumentation.
October DESY PRC Instrumentation of the Very Forward Region of a Linear Collider Detector Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell.
Fast and Precise Luminosity Measurement at the ILC Ch.Grah LCWS 2006 Bangalore.
Novembre 2008LCWS Chicago FCAL Report W. Lohmann, DESY Design FE Electronics Sensors and Sensor Tests Plans Labs involved: Argonne, BNL, Vinca Inst, Belgrade,
Beamdiagnostics using BeamCal C.Grah FCAL Workshop, Paris,
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
LumiCal background and systematics at CLIC energy I. Smiljanić, Vinča Institute of Nuclear Sciences.
Octobre 2007LAL Orsay Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
Very Forward Instrumentation: BeamCal Ch. Grah FCAL Collaboration ILD Workshop, Zeuthen Tuesday 15/01/2008.
Initial proposal for the design of the luminosity calorimeter at a 3TeV CLIC Iftach Sadeh Tel Aviv University March 6th 2009
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
Doses and bunch by bunch fluctuations in BeamCal at the ILC Eliza Teodorescu FCAL Collaboration Meeting June 29-30, 2009, DESY-Zeuthen, Germany.
Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell. Univ. Cracow,
The Optimized Sensor Segmentation for the Very Forward Calorimeter
Testbeam plans for LEP instrumentation
Testbeam measurements with diamond sensors. Preliminary results
Investigation of diamond sensors for calorimetry
Testbeam Results for GaAs and Radiation-hard Si Sensors
PERFORMANCE OF THE METAL RADIATION MONITORING SYSTEMS
Radiation hard sensors for ILC forward calorimeter
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006

11/09/2006 C.Grah: CVD Diamonds2 Contents  Very forward region of the detectors for the International Linear Collider  BeamCal – requirements  Testbeam at CERN  Linearity of the response of CVD diamonds  Testbeam at the TU Darmstadt  Radiation hardness of CVD diamonds  Conclusions

11/09/2006 C.Grah: CVD Diamonds3 Very Forward Region of the ILC Detectors Interaction point  The purpose of the instrumentation of the very forward region is:  Hermeticity: increase the coverage to polar angles > 5mrad  Optimize Luminosity  EM calorimeter with sandwich structure:  30 layers of 1 X 0 o3.5mm W and 0.3mm sensor  Angular coverage from 5mrad to 28 mrad  Moliére radius R M ≈ 1cm  Segmentation between 0.5 and 0.8 x R M BeamCal LDC

11/09/2006 C.Grah: CVD Diamonds4 The Challenges for BeamCal  e+e- pairs from beamstrahlung are deflected into the BeamCal  e + e - per BX => 10 – 20 TeV total energy dep.  ~ 10 MGy per year strongly dependent on the beam and magnetic field configuration => radiation hard sensors  Detect the signature of single high energetic particles on top of the background. => high dynamic range/linearity e-e- e+e+ Creation of beamstrahlung at the ILC ≈ 1 MGy/a ≈ 5 MGy/a e-e- e-e- γ e-e- γ e+e+ e.g. Breit-Wheeler process

11/09/2006 C.Grah: CVD Diamonds5 Polycrystalline Chemical Vapour Deposited Diamonds  pCVD diamonds are an interesting material:  radiation hardness (e.g. LHC pixel detectors)  advantageous properties like: high mobility, low ε R = 5.7, thermal conductivity  availability on wafer scale  Samples from two manufacturers are under investigation:  Element Six TM  Fraunhofer Institute for Applied Solid-State Physics – IAF  1 x 1 cm 2  μm thick (typical thickness 300μm)  Ti(/Pt)/Au metallization (courtesy of IAF)

11/09/2006 C.Grah: CVD Diamonds6 Linearity Test at CERN PS Hadronic beam, 3 & 5 GeV Fast extraction mode ~ particles / ~10 ns ADC signal gate 10 ns 17 s Diamond Setup Beam Scint.+ PMTs. Response of diamond sensor to beam particles (no preamplifier/attenuated) Photomultiplier signals

11/09/2006 C.Grah: CVD Diamonds7 Response vs. Particle Fluence 30% deviation from a linear response for a particle fluence up to ~10 6 MIP/cm 2 The deviation is at the level of the systematic error of the fluence calibration. E64 FAP2 Fraunhofer IAF Element Six

11/09/2006 C.Grah: CVD Diamonds8 High Dose Irradiation  Irradiation up to several MGy using the injector line of the S-DALINAC: 10 ± MeV and beam currents from 10 to 100 nA corresponding to about 59 to 590 kGy/h Superconducting DArmstadt LINear ACcelerator Technical University of Darmstadt Energy spectrum of shower particles in BeamCal V.Drugakov 2X 0

11/09/2006 C.Grah: CVD Diamonds9 Preparations and Programme GEANT4 simulation of the geometry => R = N FC /N Sensor = 0.98 /particle = 5.63 MeV/cm Beam setup SampleThickness, µm Dose, MGy E6_B2 (E6)500>1 DESY 8 (IAF)300>1 FAP 5 (IAF)470>5 E6_4p (E6)470>5 Apply HV to the DUT Measure CCD ~20 min Irradiate the sample ~1 hour CCD: Charge Collection Distance collimator preamp box absorber

11/09/2006 C.Grah: CVD Diamonds10 Realization: Beam Setup exit window of beam line collimator (I Coll ) sensor box (I Dia, T Dia, HV) Faraday cup (I FC, T FC )

11/09/2006 C.Grah: CVD Diamonds11 CCD Setup typical spectrum of an E6 sensor Sr90 source Preamplifier Sensor box Trigger box & Gate PA discr delay ADC Sr 90 diamond Scint. PM1 PM2 Setups partly financed by EUDET.

11/09/2006 C.Grah: CVD Diamonds12 Results: CCD vs. Dose 100 nA (E6_4p)100 nA (FAP5) Silicon starts to degrade at 30 kGy. High leakage currents. Not recoverable. CCD = Q meas /Q induced x thickness Bias voltage = 400V ≈> 1 V/μm After absorbing 7MGy: CVD diamonds still operational.

11/09/2006 C.Grah: CVD Diamonds13 Behaviour after Irradiation Slight increase of currents for higher doses. No significant change of the current-voltage characteristics up to 1.5 MGy.

11/09/2006 C.Grah: CVD Diamonds14 CCD Behaviour after Irradiation after 1.5 MGy ~ -30% ~ -80% after 7 MGy

11/09/2006 C.Grah: CVD Diamonds15 After Irradiation: IAF Sample strong „pumping“ behaviour. before/after ~ 7MGy signal recovery after 20 Gy ▪ FAP 5 irradiated, 1st measurement ▪ FAP 5 irradiated, additional 20 Gy ▪ before irradiation ▪ after irradiation

11/09/2006 C.Grah: CVD Diamonds16 Summary  PCVD diamonds are an interesting material as sensors for the BeamCal.  The linearity of pCVD diamonds up to particle fluences of 10 6 particles/cm 2 /10ns is better than 30%.  High dose irradiation using 10MeV electrons shows:  all CVD diamonds stay functional even after absorbing up to 7MGy.  degradation of the signal at high doses and dose rates.  partial recovery of the signal after absorbing additional small doses (~20 Gy).  wide variation of the signal sizes as a function of the absorbed dose is an issue for the use as a sensor for BeamCal.  Started to investigate also other materials (GaAs, SiC) as alternative.  Successfull irradiation-testbeam at the S-DALINAC. We plan to repeat the irradiation with more and other types of sensors next year.