ENE 428 Microwave Engineering
Smith Chart Impedance measured at a point along a transmission line depends not only on what is connected to the line, but also on the properties of the.
Chapter 13 Transmission Lines
Transmission Line Theory
ENE 428 Microwave Engineering
EKT241 – ELECTROMAGNETICS THEORY
EKT 441 MICROWAVE Communications
Chapter Fourteen: Transmission Lines
UNIVERSITI MALAYSIA PERLIS
UNIVERSITI MALAYSIA PERLIS
Microwave Engineering Instructor: Athar Hanif
ELCT564 Spring /9/20151ELCT564 Chapter 2: Transmission Line Theory.
Chapter 2: Transmission Line Theory
Lecture 9 Last lecture Parameter equations input impedance.
Electromagnetics (ENGR 367) The Smith Chart: A Graphical Method for T-lines.
Instructor: Engr. Zuneera Aziz Course: Microwave Engineering
Antennas and Propagation
LECTURE 2. IMPEDANCE MATCHING
Chapter 5: Impedance Matching and Tuning
Advanced Microwave Measurements
Impedance Matching and Tuning
ENE 428 Microwave Engineering
EKT 441 MICROWAVE COMMUNICATIONS
1 ENE 429 Antenna and Transmission lines Theory Lecture 4 Transmission lines.
ECE 546 – Jose Schutt-Aine 1 ECE 546 Lecture -04 Transmission Lines Spring 2014 Jose E. Schutt-Aine Electrical & Computer Engineering University of Illinois.
Lecture 6.
5. Impedance Matching and Tuning
ENE 490 Applied Communication Systems Lecture 3 Stub matching, single- and two-port networks DATE: 27/11/06.
Chapter 2. Transmission Line Theory
IMPEDANCE MATCHING IN HIGH FREQUENCY LINES UNIT - III.
10. Transmission Line 서강대학교 전자공학과 윤상원 교수
CHAPTER 4 TRANSMISSION LINES.
TELECOMMUNICATIONS Dr. Hugh Blanton ENTC 4307/ENTC 5307.
Lossless Transmission Line If Then: All TEM, L’C’=µε Selected conductors: High conductivities Dielectric materials: negligible conductivities.
Microwave Network Analysis
1 RS ENE 428 Microwave Engineering Lecture 5 Discontinuities and the manipulation of transmission lines problems.
1 RS ENE 428 Microwave Engineering Lecture 4 Reflection and Transmission at Oblique Incidence, Transmission Lines.
116/11/50 ENE 490 Applied Communication Systems Lecture 2 circuit matching on Smith chart.
Yi HUANG Department of Electrical Engineering & Electronics
1.  Transmission lines or T-lines are used to guide propagation of EM waves at high frequencies.  Examples: › Transmitter and antenna › Connections.
Lecture 5.
ENE 428 Microwave Engineering
ENE 428 Microwave Engineering
ENE 490 Applied Communication Systems
Chapter 2. Transmission Line Theory
1.  Transmission lines or T-lines are used to guide propagation of EM waves at high frequencies.  Distances between devices are separated by much larger.
Chapter9 Theory and Applications of Transmission Lines.
Notes 16 ECE Microwave Engineering Fall 2015 Impedance Matching Prof. David R. Jackson Dept. of ECE 1.
ELEC 401 MICROWAVE ELECTRONICS Lecture on Matching
Smith Chart & Matching Anurag Nigam.
Applied EM by Ulaby, Michielssen and Ravaioli
Chapter 10. Transmission lines
Microwave Circuit Design
Microwave Engineering by David M. Pozar Ch. 4.1 ~ 4 / 4.6
ELEC 401 MICROWAVE ELECTRONICS Lecture on Smith Chart
ENE 429 Antenna and Transmission Lines Theory
Non-ideal property – crosstalk
ENE 429 Antenna and Transmission lines Theory
ENE 428 Microwave Engineering
ELEC 401 MICROWAVE ELECTRONICS Lecture on Smith Chart
ENE 429 Antenna and Transmission lines Theory
ENE 428 Microwave Engineering
Transmission lines II 1.
IMPEDANCE MATCHING & SMITH CHART
ENE 428 Microwave Engineering
ENE 428 Microwave Engineering
Voltage Reflection Coefficient
4th Week Seminar Sunryul Kim Antennas & RF Devices Lab.
ENE 428 Microwave Engineering
Presentation transcript:

ENE 428 Microwave Engineering Lecture 6 Transmission lines problems and microstrip lines RS

Review Input impedance for finite length line Quarter wavelength line Half wavelength line Smith chart A graphical tool to solve transmission line problems Use for measuring reflection coefficient, VSWR, input impedance, load impedance, the locations of Vmax and Vmin

Ex1 ZL = 25+j50 , given Z0 = 50  and the line length is 60 cm, the wavelength is 2 m, find Zin. Ex2 A 0.334 long TL with Z0 = 50  is terminated in a load ZL = 100-j100 . Use the Smith chart to find a) L b) VSWR c) Zin d) the distance from load to the first voltage minimum

Ex3 ZL = 80-j100  is located at z = 0 on a lossless 50  line, given the signal wavelength = 2 m, find a) If the line is 0.8 m in length, find Zin. b) VSWR c) What is the distance from load to the nearest voltage maximum d) what is the distance from the input to the nearest point at which the remainder of the line could be replaced by a pure resistance?

Ex4 A 0.269- long lossless line with Z0 = 50  is terminated in a load ZL = 60+j40 . Use the Smith chart to find a) L b) VSWR c) Zin d) the distance from the load to the first voltage maximum

Impedance matching To minimize power reflection from load Zin = Z0 Matching techniques 1. Quarter - wave transformers for real load 2. single - stub tuners 3. lumped – element tuners The capability of tuning is desired by having variable reactive elements or stub length.

Quarter-Wave Transformer

Simple matching by adding reactive elements (1) EX5, a load 11+j25  is terminated in a 50  line. In order for 100% of power to reach a load, ZLoad must match with Z0, that means ZLoad = Z0 = 50 . This value corresponds to center of the chart.

Simple matching by adding reactive elements (1)

Distance d WTG = (0.188-0.076) = 0.112  to point 1+ j2 Therefore cut TL and insert a reactive element that has a normalized reactance of -j2. The normalized input impedance becomes 1+ j2 - j2 = 1 which corresponds to the center or the Smith chart.

Simple matching by adding reactive elements (1) EX5, a load 10-j25  is terminated in a 50  line. In order for 100% of power to reach a load, ZLoad must match with Z0, that means ZLoad = Z0 = 50 . Distance d WTG = (0.5-0.424) +0.189  = 0.265  to point 1+ j2.3. Therefore cut TL and insert a reactive element that has a normalized reactance of -j2.3. The normalized input impedance becomes 1+ j2.3 - j2.3 = 1 which corresponds to the center or the Smith chart.

Simple matching by adding reactive elements (2) The value of capacitance can be evaluated by known frequency, for example, 1 GHz is given.

Single stub tuners Working with admittance (Y) (Yo = 1/Zo) since it is more convenient to add shunt elements than series elements Stub tuning is the method to add purely reactive elements

Ex6 let zL = 2 + j1, what is the admittance? Where is the location of y on Smith chart? We can easily find the admittance on the Smith chart by moving 180 from the location of z. Smith Chart is also a chart of normalized admittance. The normalized load admittance is

Stub tuners on Y-chart (Admittance chart) (1) There are two types of stub tuners Shorted end, y =  (the rightmost of the Y chart) opened end, y = 0 (the leftmost of the Y chart) l l Short-circuited shunt stub Open-circuited shunt stub

Short-circuited Shunt Stub Purely reactive tuning element follows the constant || circle along the periphery of Smith chart (z = 0  jx). Proper selection of the T-line length d allows us to choose any value of reactance that we want, whether it’s capacitive or inductive. The admittance of the short-circuited starts on the right side of the chart ( yshort = ∞ + j∞)

Stub tuners on Y-chart (Admittance chart) (2) Procedure Locate zL and then yL. From yL, move clockwise to 1  jb circle, at which point the admittance yd = 1  jb. On the WTG scale, this represents length d. 2. For a short-circuited shunt stub, locate the short end at 0.250 then move to jb, the length of stub is then l and then yl = jb. 3. For an open-circuit shunt stub, locate the open end at 0, then move to jb. 4. Total normalized admittance ytot = yd+yl = 1.

Ex: Construct a short-circuited stub matching network for a 50- line terminated in a load ZL = 20 – j55  First, normalize load impedance, zL = ZL/ZO = 0.4 – j1.1 Next, locate yL Move along the constant-|| circuit in WTG (clockwise) direction ‘till it intersects with the 1  jb circle (in this case 1 + j2.0). We travel from 0.112g to 0.187g on the WTG scale, so our through-line length (d) is 0.075g Next, we insert the short-ckted shunt stub. Admittance is on the right side of the chart at WTG = 0.250g. We move clockwise until we reach the point 0 – j2.0, located at WTG = 0.324g. This give us stub length (l) = 0.324g- 0.250g = 0.074g.

Ex: We want to construct an open-ckted shunt-stub matching network for a 50- line terminated in a load ZL =150 + j100 . Solution: First, normalize load impedance, zL = ZL/ZO = 3.0 + j2.0 Next, locate yL Move along the constant-|| circuit in WTG (clockwise) direction ‘till it intersects with the 1  jb circle (in this case 1 + j1.6). We travel from 0.474g to 0.178g on the WTG scale. We add 0.500g to the end point, so our through-line length (d) is (0.500g) – 0.474g + 0.178g = 0.204g Next, we insert the open-ckted shunt stub. On the admittance chart, the location of the open-ckted is on the left side of the chart at WTG = 0.000g. We move clockwise until we reach the point 0 – j1.6, located at WTG = 0.339g. This give us stub length (l) = 0.339g.

Homework Prob. 2.41: A load impedance ZL = 25 + j90  is to be matched to a 50- line using an open-ended shunt-stub tuner. Find the solution that minimizes the length of the shorted stub.

Microstrip (1) The most popular transmission line since it can be fabricated using printed circuit techniques and it is convenient to connect lumped elements and transistor devices. By definition, it is a transmission line that consists of a strip conductor and a grounded plane separated by a dielectric medium

Microstrip (2) The EM field is not contained entirely in dielectric so it is not pure TEM mode but a quasi-TEM mode that is valid at lower microwave frequency. The effective relative dielectric constant of the microstrip is related to the relative dielectric constant r of the dielectric and also takes into account the effect of the external EM field. Typical electric field lines Field lines where the air and dielectric have been replaced by a medium of effective relative permittivity, eff

Microstrip (2.1) Some typical dielectric substrates are RT/Duroid® (a trademark of Rogers Corporation, Chandler, Arizona), which is available with several values of εr (e.g. ε = 2.23εo, ε = 6εo, ε = 10.5εo, etc.); quartz (ε = 3.7εo); alumina (ε = 9εo) and Epsilam-109® (ε = 10εo). Various substrate materials are available for the construction of microstrip lines, with practical values of εr ranging from 2 to 10. The substrate material comes plated on both sides with copper, and an additional layer of gold plating on top of the copper is usually added after the ckt pattern is etched in order to prevent oxidation. Typical plating thickness of copper is from ½ mils to 2 mils (1 inch = 1000 mils). The value of εr and the dielectric thickness (h) determine the width of the microstrip line for a given Zo. These parameters also determine the speed of propagation in the line, and consequently its length. Typical thickness are 25, 30, 40, 50 and 100 mils.

Microstrip (3) Therefore in this case and and The evaluation of up, Zo and λ in microstrip line requires the evaluation of εeff and C. There are different methods for determining εeff and C and, of course, closed-form expressions are of great importance in microstrip-line design. The evaluation of εeff and C based on a quasi-TEM mode is accurate for design purposes at lower microwave freq. However, at higher microwave freq, the longitudinal components of the EM fields are significant and the quasi-TEM assumption is no longer valid.

Evaluation of the microstrip configuration (1) Consider t/h < 0.005 and assume no dependence of frequency, the ratio of w/h and r are known, we can calculate Z0 as

Evaluation of the microstrip configuration (2) Assume t is negligible, if Z0 and r are known, the ratio w/h can be calculated as The value of r and the dielectric thickness (h) determines the width (w) of the microstrip for a given Z0.

Characteristic impedance of the microstrip line versus w/h

Normalized wavelength of the microstrip line versus w/h

Ex8 A microstrip material with r = 10 and h = 1 Ex8 A microstrip material with r = 10 and h = 1.016 mm is used to build a TL. Determine the width for the microstrip TL to have a Z0 = 50 . Also determine the wavelength and the effective relative dielectric constant of the microstrip line.

Wavelength in the microstrip line Assume t/h  0.005,

Attenuation (losses in microstrip lines) conductor loss dielectric loss radiation loss where c = conductor attenuation (Np/m) d = dielectric attenuation (Np/m

Conductor attenuation If the conductor is thin, then the more accurate skin resistance can be shown as

Dielectric attenuation