New Geant4 Electromagnetic Physics Developments for Ion Therapy Applications Toshiyuki Toshito 1, Alexander Bagulya 2, Anton Lechner 3,4, Vladimir Ivanchenko.

Slides:



Advertisements
Similar presentations
Precision validation of Geant4 electromagnetic physics Katsuya Amako, Susanna Guatelli, Vladimir Ivanchenko, Michel Maire, Barbara Mascialino, Koichi Murakami,
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Preliminary studies for T2 primary target for the NA61 fragmentation beam run 11 th October 2010 – NA61 Collaboration Meeting M. Calviani on behalf of.
The Vin č a Institute of Nuclear Sciences, Belgrade, Serbia * Universita degli studi di Bologna, DIENCA, Italia Radovan D. Ili}, Milan Pe{i}, Radojko Pavlovi}
1 Activation problems S.Agosteo (1), M.Magistris (1,2), Th.Otto (2), M.Silari (2) (1) Politecnico di Milano; (2) CERN.
Parameterized Shower Simulation in Lelaps: a Comparison with Geant4 Daniel Birt, Amy Nicholson.
Simulation of heavy ion therapy system using Geant4 Satoru Kameoka ※ 1, ※ 2 Takashi SASAKI ※ 1, ※ 2, Koichi MURAKAMI ※ 1, ※ 2, Tsukasa ASO ※ 2 ※ 3, Akinori.
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
Hadronic and Electromagnetic Physics: special applications V.Ivanchenko BINP, Novosibirsk, Russia & CERN, Geneve, Switzerland.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Geant4-SPENVIS1 2006/11/08 Pasadena Geant4 validation on proton stopping power Tsukasa Aso Toyama National College of Maritime Technology, JST CREST.
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
1 M.G. Pia et al. The application of GEANT4 simulation code for brachytherapy treatment Maria Grazia Pia INFN Genova, Italy and CERN/IT
Validation of the Bremsstrahlung models Susanna Guatelli, Barbara Mascialino, Luciano Pandola, Maria Grazia Pia, Pedro Rodrigues, Andreia Trindade IEEE.
Geant4-INFN (Genova-LNS) Team Validation of Geant4 electromagnetic and hadronic models against proton data Validation of Geant4 electromagnetic and hadronic.
Energy deposition for 10 MeV neutrons in oxygen, carbon, argon and hydrogen gaseous chambers (1mx1mx1m). Energy Deposition in 90% argon (1.782mg/cm 3 )
Maria Grazia Pia Systematic validation of Geant4 electromagnetic and hadronic models against proton data Systematic validation of Geant4 electromagnetic.
Budker Inst. of Physics IHEP Protvino MEPHI Moscow Pittsburg University.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Geant4 simulation of the attenuation properties of plastic shield for  - radionuclides employed in internal radiotherapy Domenico Lizio 1, Ernesto Amato.
Verification of the Dose Distributions with Geant4 Simulation for Proton Therapy Tsukasa Aso (Toyama College of Maritime Tech.) A.Kimura (JST CREST) S.Tanaka.
G EANT 4 energy loss of protons, electrons and magnetic monopole M. Vladymyrov.
Geant4: Electromagnetic Processes 2 V.Ivanchenko, BINP & CERN
SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,
Summary of Work Zhang Qiwei INFN - CIAE. Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases.
Preliminarily results of Monte Carlo study of neutron beam production at iThemba LABS University of the western cape and iThemba LABS Energy Postgraduate.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Precision Analysis of Electron Energy Deposition in Detectors Simulated by Geant4 M. Bati č, S. Granato, G. Hoff, M.G. Pia, G. Weidenspointner 2012 NSS-MIC.
EM physics progress20 January Geant4 Electromagnetic Physics Progress S.Incerti and V.Ivanchenko for Geant4 electromagnetic groups 20 January 2008.
1 Dr. Sandro Sandri (President of Italian Association of Radiation Protection, AIRP) Head, Radiation Protection Laboratory, IRP FUAC Frascati ENEA – Radiation.
Experimental part: Measurement the energy deposition profile for U ions with energies E=100 MeV/u - 1 GeV/u in iron and copper. Measurement the residual.
Radiation damage calculation in PHITS
Passive detectors (nuclear track detectors) – part 2: Applications for neutrons This research project has been supported by the Marie Curie Initial Training.
Precision analysis of Geant4 condensed transport effects on energy deposition in detectors M. Batič 1,2, G. Hoff 1,3, M. G. Pia 1 1 INFN Sezione di Genova,
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
Interactions of Particles with Matter
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
Interfacing the JQMD and JAM Nuclear Reaction Codes to Geant4 Stanford Linear Accelerator Center Koi, Tatsumi
Physics Data Libraries: Content and Algorithms for Improved Monte Carlo Simulation Physics data libraries play an important role in Monte Carlo simulation:
Study of high energy cosmic rays by different components of back scattered radiation generated in the lunar regolith N. N. Kalmykov 1, A. A. Konstantinov.
Validation of EM Part of Geant4
Geant4 Activities in Japan Some news from Takashi Sasaki, Koichi Murakami, Akinori Kimura and colleagues.
MCS: Multiple Coulomb Scattering Sophie Middleton.
V.Ivanchenko Salamanca1 Geant4: Hadronic Processes 1  Cross sections  Secondary generators  Nuclear interactions at rest  CHIPS model.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Numerical Model of an Internal Pellet Target O. Bezshyyko *, K. Bezshyyko *, A. Dolinskii †,I. Kadenko *, R. Yermolenko *, V. Ziemann ¶ * Nuclear Physics.
Marina Golubeva, Alexander Ivashkin Institute for Nuclear Research RAS, Moscow AGeV simulations with Geant4 and Shield Geant4 with Dpmjet-2.5 interface.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
1 Activation by Medium Energy Beams V. Chetvertkova, E. Mustafin, I. Strasik (GSI, B eschleunigerphysik), L. Latysheva, N. Sobolevskiy (INR RAS), U. Ratzinger.
Validation of GEANT4 versus EGSnrc Yann PERROT LPC, CNRS/IN2P3
Koichi MurakamiGeant4 Physics Verification and Validation (17-19/Jul./2006) 1 Results from the recent carbon test beam at HIMAC Koichi Murakami Statoru.
Achim Stahl RWTH Aachen Hadron Therapy, Jülich Oct, Workshop Nuclear Models for Use in Hadron Therapy October 8./ Achim Stahl – RWTH Aachen.
Validation of Geant4 against the TARC benchmark: Testing neutron production, transportation and interaction TARC – experimental set-up and aims Geant4.
INTERCOMPARISON P3. Dose distribution of a proton beam
Induced-activity experiment:
Shintaro Hashimoto1, Yosuke Iwamoto 1, Tatsuhiko Sato 1, Koji Niita2,
A. R. Garcia, E. Mendoza and D. Cano-Ott
1. Introduction Secondary Heavy charged particle (fragment) production
Model Approach for Standard EM Physics
Geant4 physics validation: Bragg Peak
The Hadrontherapy Geant4 advanced example
Design of A New Wide-dynamic-range Neutron Spectrometer for BNCT with Liquid Moderator and Absorber S. Tamaki1, I. Murata1 1. Division of Electrical,
P. Rodrigues, A. Trindade, L.Peralta, J. Varela
Precision validation of Geant4 electromagnetic physics
G. A. P. Cirrone1, G. Cuttone1, F. Di Rosa1, S. Guatelli1, A
AN ORIGINAL MODEL FOR THE SIMULATION OF LOW ENERGY ANTIPROTONS
The Geant4 Hadrontherapy Advanced Example
Presentation transcript:

New Geant4 Electromagnetic Physics Developments for Ion Therapy Applications Toshiyuki Toshito 1, Alexander Bagulya 2, Anton Lechner 3,4, Vladimir Ivanchenko 4,5,6, Michel Maire 7,8, Takashi Akagi 9, Tomohiro Yamashita 9 On behalf of the Geant4 Standard electromagnetic Working Group 1 Quality Life 21 Johoku Promotion Office, Health Department, Health and Welfare Bureau, Nagoya City, 2 Levedev Physics Institute, Moscow, Russia, 3 Atomic Institute of the Austrian Universities, Vienna University of Technology, Vienna, Austria, 4 CERN, CH-1211 Geveva 23, Switzerland, 5 Ecoanalytica, Moscow, Russia, 6 Metz University, LPMC, Metz, France, 7 Geant4 Associates International Ltd, United Kingdom, 8 LAPP, Annecy-le-vieux, France, 9 Hyogo Ion Beam Medical Center (HIBMC), Tatsuno, Japan Introduction Geant4 1,2) is a Monte Carlo simulation toolkit for simulating the passage of particles through matter emerging from the high-energy physics community. It is capable of handling all physics processes including electromagnetic, hadronic and nucleus-nucleus interactions, which are indispensable to calculate three-dimensional dose distributions in ion therapy. In recent years, new developments were carried out respectively addressing Geant4 electromagnetic (EM) physics models and software infrastructure. 3,4) Major updates of software for ion transport are aimed to improve models for energy loss which is the most important factor to determine depth-dose distribution as follows. First of all, numerical tables of stopping powers as a function of energy for all ion-material combinations available in the ICRU 73 report are built in Geant4. A spline algorithm for interpolation was introduced to handle EM data: stopping powers, ranges and cross sections, which are essential for ion Bragg peak simulation. Also, a new energy loss fluctuation model was introduced for ions and nuclear stopping model was implemented as a separate Geant4 process. In summary, these developments allow to obtain precise results for the transport of therapeutic ion beams, which are stable against simulation step length and delta-ray production threshold. These new functions, optimized parameters and a proper choice of physics models are provided with the Geant4 version 9.3. Conclusion We have developed simulation codes to handle electromagnetic processes in Geant4 in an attempt to improve the accuracy of dose calculations for radiotherapy using ions. Recent major developments are aimed to improve the stability against range cut or simulation steps and the models for energy loss which is the most important factor to determine range. We validated simulated depth-dose distributions of therapeutic carbon ions incident on water against published and new experimental results performed at practical broad beam irradiation systems for carbon ion radiotherapy. We found simulation is very stable against range cut and able to reproduce the measured ranges fairly well. References 1) S. Agostinelli et al., “Geant4 - a simulation toolkit,” Nucl. Instr. Methods, A (2003). 2) J. Allison et al., “Geant4 developments and applications,” IEEE Trans. Nucl. Sci., (2006). 3) A. Lechner et al.,“Validation of recent Geant4 physics models for application in carbon ion therapy,” Nucl. Instr. Methods, B (2010). 4) V. Ivanchenko et al., “Recent improvements in Geant4 electromagnetic physics models and interfaces,” in proceedings of this conference. 5) T. Aso et al., “Verification of the dose distributions with GEANT4 simulation for proton therapy,” IEEE Trans. Nucl. Sci., (2005). 6) T. Aso et al., “GEANT4 based simulation framework for particle therapy system,” Nuclear Science Symposium IEEE, Conference Record (2007). 7) G. Folger et al., “The Binary Cascade,” Eur. Phys. J. A (2004). 8) S. Kameoka et al., “Dosimetric evaluation of nuclear interaction models in the Geant4 Monte Carlo simulation toolkit for carbon ion radiotherapy,” Radiol. Phys. Technol., (2008). 9) T. Koi, “New native QMD code in Geant4,” Nuclear Science Symposium Conference Record NSS’08. IEEE, (2008). Material and Methods Physics models for ions in Geant4 In version 9.3 of Geant4, models simulating the energy loss and its fluctuation are implemented in the C++ class G4hIonisation for protons, deuterons and tritons, and in the class G4ionIonisation for all other ions. By default, stopping power models of the Geant4 ‘Standard EM Package’ are used. For ions below 2 MeV/u, the Helium ion parameterization from the ICRU 49 report is employed. Above 2 MeV/u, the restricted energy loss rate of ions is calculated by using the Bethe-Bloch formula including Barkas, Bloch and Mott corrections. A correction term is applied to enable a smooth transition between these two models. In Geant4 9.3, the mean ionization potential of liquid water is set to I = 78 eV according to revised version of ICRU 73. A new energy loss model for ions heavier than Helium, G4IonParameterisedLossModel, and corresponding software to handle material data were implemented with focus on Geant4-based ion therapy applications. In the energy range from 25 keV/u to 1 GeV/u, the model uses ICRU 73 stopping powers, which cover a variety of combinations of different ion species (Z = 3-18, 26) and absorbers (25 elemental materials and 31 compounds). The energy loss of other ions is determined by means of a scaling method. For interpolation of all data the cubic spline interpolation is applied. Delta-electron production above the production threshold is simulated using standard algorithm. Geometry and scoring This implementation used the class library developed for Geant4 in previous work 5,6) (Fig.1). To obtain depth-dose distributions in water tanks, water was equally sliced along the beam axis and energy deposition of each slice was scored. The slice thickness was set to 0.1 mm. Thus, simulation steps for ions and secondary electrons were forced to be smaller. Results and Discussion Stability against range cut First, we examine the stability of results against Geant4 cut in range with a simple geometry, i.e. only a water phantom is put in the vacuum. The Geant4 cut in range approach allows defining spatial precision of simulation by one number. At the initialization time of Geant4, cut in range recomputed into production thresholds for delta-electrons and bremsstrahlung photons. Ion therapy application is a very sensitive test of stability, because the Bragg peak of ions is very narrow. For simulation a standard set of Geant4 processes was used. For electromagnetic physics it was Option3 physics constructor, which include the new model of ion ionization based on ICRU 73 data. The Binary cascade model 7) was used to simulate inelastic nuclear reactions of ions, protons and neutrons. We simulated the Bragg peak of 400 MeV/u carbon beam in water with various cut in range values from mm to 1km. In Figure 2 simulated Bragg curve and in Figure 3 range and deviation in peak height are shown as functions of range cuts. Deviation in peak position is within ± 0.1 mm (0.04 %) and in peak height within +2.4 % and % against default range cut of 1 mm. Bragg peak in water Secondly, Geant4-based depth-dose distributions are validated for 290, 320 and 400 MeV/u 12C beams in water. For 290 and 400 MeV/u, previously published data 8) are adopted, which were measured at HIMAC of National Institute of Radiological Sciences (NIRS) in Japan. For 320 MeV/u, new data measured at HIBMC are used for analysis. These two beam-lines are equipped for broad beam irradiation for carbon ion radiotherapy. We pay particular attention to the ion range. The parameterized energy loss model was used to simulate electronic energy loss. The QMD model 9) with the standard de- excitation module of Geant4 for the de-excitation of excited residual nuclei was used to simulate inelastic nuclear reaction of ions. The measured dose profiles considered in this study are associated with a Gaussian energy spectrum, with a standard deviation of approximately 0.07 %. Figure 4 shows simulated depth-dose distributions along with experimental measurements. We normalized simulation results such that they coincide with the measurement at the phantom entrance. We have not applied any correction such as scaling or shifting in the horizontal axis in order to be able to compare the absolute range. As a whole, we found very good agreement between measurements and MC in range (Fig.5). The satisfactory agreement of Geant4 simulations with experimental values confirms the accuracy of energy loss algorithms invoked at each particle step in the simulation, and also demonstrates the precision of the cubic spline interpolation algorithm. In addition, good agreement between measurements and MC is also found in the dose distributions beyond Bragg peak. This means that the dose coming from fragmentation products are precisely simulated by using the QMD model. On the other hand, the MC simulations overestimate peak/plateau ratio. Possible experimental reasons of this are underestimation of the initial energy spread, heterogeneity of the effective thickness of materials installed in the beam line, for example, scatterer and electrode in the monitors, and some systematic of the ionization chamber measurements. For practical applications, these factors should be considered carefully. However, MC simulation may be also responsible for the discrepancies. The sensitive components of Geant4 simulation are energy dependence of stopping power in water and air, model of fluctuations of energy loss of ions, and model of ion nuclear fragmentation. The method of normalization chosen for this work maximally emphasizes the difference in the peak/plateau ratio. For practical applications ridge filters and range compensators are used the observed difference significantly reduced. Water phantom 30cmx30cmx50cm 320MeV/n 12 C Fig. 2. Zoomed simulated depth-dose curves for various range cuts. Fig. 3. Stability of simulation versus range cut for (a) range; (b) peak heights (unit for cut = 1 mm). Fig. 4. Simulated depth-dose curves along with published data 8) for HIMAC 290 and 400 MeV/u and new data for HIBMC beam 320 MeV/u. Fig. 5. Differences between simulated ranges and measurements. Fig. 1. Geometry of HIBMC facility