APAR LRU Brick Mechanical Design EOL APAR Team (Jim Ranson – EOL Design and Fabrication Services presenting) EOL APAR Advisory Panel 19-20 March 2015.

Slides:



Advertisements
Similar presentations
High Density Mezzanine Connector System (1.00mm)
Advertisements

Packaging.
VL Connector To introduce the VL wire-to-board and wire-to-wire, crimp style connector series.
Electronics Cooling MPE 635
Manchester 09/sept/2008A.Falou & P.Cornebise {LAL-Orsay}1 CALICE Meeting/ Manchester Sept 2008 SLAB Integration & Thermal Measurements.
CALICE Dave Bailey. Aims and Objectives Develop the technology to build a high- resolution tracking calorimeter for ILC experiments Main thrusts: –Testbeam.
Electronics Cooling MPE 635 Mechanical Power Engineering Dept.
Thermal Analysis of a Integrated Power Electronics Module MANE 6980 Nicholas Palumbo 12/05/2012.
Part F Practical Applications. 28. Fan-Cooled Enclosure of a PC System Physical System The physical system of interest is a fan-cooled enclosure containing.
Integration of Cavities and Coupling Coil Modules Steve Virostek Lawrence Berkeley National Laboratory MICE Collaboration Meeting March 28 – April 1, 2004.
Mechanical Status of ECAL Marc Anduze – 30/10/06.
CPU Cooling Benjamin Crummett. Objective Reduce CPU operating temperature. Reduce CPU operating temperature. Over clock the CPU without over heating it.
Part-C Main topics B1- Electronics cooling methods in industry Heat sinks and cold plates for electronic cooling "Heat sinks" Heat pipes in electronic.
CHE/ME 109 Heat Transfer in Electronics
ECE 4411 Air-Gap Power The power transferred electromagnetically across the air gap between the stator and rotor is called the “air-gap power”, or “gap.
THERMAL CONDUCTION LABORATORY Dr. E. Marotta Department of Mechanical Engineering Clemson University Clemson, SC.
2006 Oct. 19 DES Project -- Vaidas Simaitis, University of Illinois1 DHE – Detector Head Electronics Monsoon 80mm Crate Heat Load.
Heat Sink Selection Thermal Management of Electronics
Design of Heat Sinks P M V Subbarao Mechanical Engineering Department IIT Delhi Success Based on Cooling Challenges …….
Reconfigurable Patch Antenna With Matching Network Presented by: Mike Bly, Josh Rohman Advisor: Dr. Prasad N. Shastry.
Solderless PCB Launch Connectors
Lab-1,Week 1, EML 3016 C- Spring 2003 Electronic Device Cooling A thin (assume zero thickness) electronic chip has a square shape of an area 5x5 cm 2,
AIDA FEE64 production report June 2011 LYCCA tests and MBS Production of FEE64 Preparation for October test. 13th June
PACKAGING SOLUTIONS Christian Ganninger Product Manager MicroTCA, Backplanes and PSU EMEA  : : Rugged.
© Psion Confidentialpsion.com | ingenuityworking.com Specific Partner Kitting UHF Xmod Circular + End Cap Scanner Authors : Fabien BARRY Version : A00.
© International Rectifier DirectFET  MOSFETs Double Current Density In High Current DC-DC Converters With Double Sided Cooling.
A PCB has 2 signal layers, a split power layer and one ground layer. It also has two solder mask and two silkscreen layers. Is the board classified as:
Building a PC. Motherboard Selection Ensure the selected motherboard is appropriate for the processor model and frequency you are planning to use AMD.
Marc Anduze – 09/09/2008 Report on EUDET Mechanics - Global Design and composite structures: Marc Anduze - Integration Slab and thermal measurements: Aboud.
AIDA 1 Mezzanine board Contacts for underside connectors Thermal contact pads.
10c-1 MAVEN IPER May 22-23, 2012 Particles and Fields Package Pre-Environmental Review May , c - Board Analysis Update Christopher Smith Mars.
For Official Use Only; Information herein NOT Approved for Export; Contains Proprietary Protected Information; NOT for Public Release 1 WIPER PDR Stanford,
1 SPP FIELDS MEP Main Electronics Package Preliminary Design Review Bill Donakowski UCB/SSL 13/14 NOVEMBER 2013 MAVEN PFDPU Flight.
Sept. 2008EFW INST+SOC PDR IDPU Chassis Mechanical Design and Development Bill Donakowski Mechanical Engineer UCB/SSL
Mechatronics Task Force, 26-nov-02 Olivier Teller, CERN EP-CMA1 Cooling Mechatronics Schedule.
Main Electronics Package
FVTX Review, November 17th, FVTX Mechanical Status: WBS 1.6 Walter Sondheim - LANL Mechanical Project Engineer; VTX & FVTX.
For Official Use Only; Information herein NOT Approved for Export; Contains Proprietary Protected Information; NOT for Public Release 1 WIPER PDR Stanford,
Feasibility Study and Information collection for quotation Miley Combo and Main Antenna Based on files received on Version: 2.
Vessel dimensions GTK assembly carrier Electrical connections Cooling pipes integration Vessel alignment with the beam Next steps Conclusion 3/10/20102.
1 PFDPU Mechanical Packaging PEER REVIEW MAVEN PFDPU Particle and Fields Data Processing Unit Mechanical Packaging and Design Overview May 09, 2011 Bill.
TRIO-CINEMA 1 UCB, 2/08/2010 CINEMA Solar Array Design Review Yashraj Khaitan David Glaser Kevin Jenkins Chris Pasma Space Sciences Laboratory University.
– EUDET module – Report from Mechanics Brainstorming Marc Anduze – 30/06/2009 Laboratoire Leprince Ringuet Ecole polytechnique - Palaiseau.
PCB Design Overview Lecture 11
MEMS Packaging ד " ר דן סתר תכן וייצור התקנים מיקרומכניים.
Marc Anduze – CALICE Meeting – KOBE 10/05/07 Mechanical R&D for Technological EUDET ECAL Prototype.
109-IDPU-Chassis-Donakowski 1 30 Sep – 01 Oct 2009DRAFT RBSP EFW ICDR 109-IDPU-Chassis-Donakowski IDPU Chassis Mechanical Design and Development Bill Donakowski.
Vessel dimensions GTK assembly carrier Electrical connections Cooling pipes integration Vessel alignment with the beam Next steps Conclusion 3/23/20102electro-mechanical.
Heat Transfer System By Team Awesome: Sub-team Awesomer.
RBSP Radiation Belt Storm Probes RBSP Radiation Belt Storm Probes RBSP/EFW CDR /30-10/1 535 IDPU Chassis Bill Donakowski Mechanical Engineer UCB/SSL.
Heat Transfer System By Team Awesome: Sub-team Awesomer.
SLAC Project-X RF Development FY12 SOW March
Genesis Technology USA, Inc. Heatsink Technologies November 2,
Internal Guide : Batch No : 4 Mrs.Punyavathi Madam
Supermicro © 2009Confidential Installation guide of air shroud for SC809 chassis + X7DWT MB.
Date of download: 9/27/2017 Copyright © ASME. All rights reserved.
IC packaging and Input - output signals
Bill Donakowski Mechanical Engineer UCB/SSL
Mechanics for front-end Electronics Of T2K-II TPCs – A Few Conceptual Ideas D. Calvet, Irfu, CEA Saclay, Gif sur Yvette Cedex, FRANCE.
ECE Engineering Design Thermal Considerations
FP420 Detector Cooling Thermal Considerations
Date of download: 3/7/2018 Copyright © ASME. All rights reserved.
OCP Mezz 3.0 Mechanical Recommendations
Thermal Simulation Discussion
THERMODYNAMIC IN ELECTRONICS
Team P15441 Mini Air Sub-System Design Review
Heat transfer Chapter 7.
Manufacturing Processes
SAS-3: Microwave laminates for connector test cards
How to design the size of heatsink
Presentation transcript:

APAR LRU Brick Mechanical Design EOL APAR Team (Jim Ranson – EOL Design and Fabrication Services presenting) EOL APAR Advisory Panel March 2015

LRU Brick Mechanical CAD Model

LRU PCB Mechanical Outline Drawing

LRU Brick PCB assembly features LRU Module has integral Wedgelok® retainers for module retention in card cage, for blind-mate RF connector guiding, and for conduction heat transfer LRU Module has integral mount/heat sink Note: SMP board mount connectors are soldered and epoxy bonded to PCB for mechanical strength Power, Data/Signal, Programming, and Test connectors

SMP Blind Mate RF connectors SMP Blind-Mate Connectors: Low insertion loss 0 – 18 GHz frequency range Used for High-Density modular packaging Allows for radial and axial misalignment Used for phased array radar and active antenna applications

LRU Brick Modules assembled into card cage LRU Module #1 Card cage for 8 LRU’s Interface connector plate Antenna patch panel Cooling fans Card guides with Wedge-lok PCB retainers LRU Modules have RF shields/covers

APAR LRU Brick Thermal Design LRU Module PCB incorporates ground plane(thermal also) into Layer 11 (AGND) LRU Module PCB incorporates filled vias for heat transfer LRU Module PCB is in thermal contact with integral mount/heat sink through compliant thermal pad to insure waste heat transfers into heat sink (avoids air gaps) Estimate of LRU Module heat dissipation is 27 Watts per module. Initial thermal analysis estimates 50 CFM cooling air is required to dissipate waste heat for 8 LRU Modules. Cooling fans chosen are rated at 111 CFM. Design provides margin to account for air pressure drop and operation above sea-level conditions. Secondary cooling via conduction from integral mount/heat sink thru Wedge-loks into card cage. View showing finned heat sinks and fan positioning relative to LRU Modules

APAR LRU Brick assembly drawing