Creative Capstone Design Development of device to measure side foot pressure for analyzing human walking Team Name : Number 1 20091825 Seo Myoung Hyoun.

Slides:



Advertisements
Similar presentations
DESIGN OF EXPERIMENTS DOE STATISTICAL EXPERIMENTS By Mike Newtown.
Advertisements

Start your learning and revising now J Griffiths for NGfL Cymru.
CONTENT I. Introduction II. DEP force for CNTs Implementation III. Experimental results IV. Conclusions.
Errro Analysis Error. Why Bother? The knowledge we have of the physical world is obtained by doing experiments and making measurements. It is important.
EXPERIMENTAL ERRORS AND DATA ANALYSIS
Adaptive Data Collection Strategies for Lifetime-Constrained Wireless Sensor Networks Xueyan Tang Jianliang Xu Sch. of Comput. Eng., Nanyang Technol. Univ.,
Aim of work The main objective of this investigation was to optimize the formulation of chitosan beads with Ketorolac tromethamine to minimize the gastrointestinal.
2.3. Measures of Dispersion (Variation):
Paper Anemometer Team Taiwan. Official Description Paper Anemometer When thin strips of paper are placed in an air flow, a noise may be heard. Investigate.
Team 7. Industry 3D controller with vibration Inventors: Armstrong, Brad A. (Carson City, NV, US) Application Number: 09/ Publication Date: 06/14/2005.
Topic 6.1 Statistical Analysis. Lesson 1: Mean and Range.
Structural Dynamics & Vibration Control Lab 1 December Department of Civil & Environmental Engineering K orea A dvanced I nstitute of S cience.
TRAINING AFFECTS KNEE KINEMATICS AND KINETICS IN CUTTING MANEUVERS IN SPORT CASEY GRAHAM TIFFANY MEIER MICHELE BENANTI.
OBSERVATIONAL METHODS © 2012 The McGraw-Hill Companies, Inc.
Performance characteristics for measurement and instrumentation system
Quality Control – Part II Tim Hanley EPA Office of Air Quality Planning and Standards.
R. I. T Multidisciplinary Senior Design Phase-Appropriate Feasibility Analysis Rochester Institute of Technology Mechanical Engineering Department Rochester,
Errors and Uncertainty In science, every measurement will have limitations on its accuracy. To indicate how well a data point should be represented, significant.
Significant Figures Part 2 Problem Solving Applications.
Human Tracking System Using DFP in Wireless Environment 3 rd - Review Batch-09 Project Guide Project Members Mrs.G.Sharmila V.Karunya ( ) AP/CSE.
Electro-Hydraulic Actuator Yooseok Jeong G Hou Chengkun Seo-Hyun Sohn Won Jang Yong-Gyu Hwang.
Robot Sung-mok Seo Ok-nam Lee Yoon-ho Na Su-min Park.
CONTENTS: 1.Abstract. 2.Objective. 3.Block diagram. 4.Methodology. 5.Advantages and Disadvantages. 6.Applications. 7.Conclusion.
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh 1, In Ho Ryu 2 and Jeong-Chay Jeon 3 * 1 Department.
Modification of ASC1 by UFM1 Is Crucial for ERα Transactivation and Breast Cancer Development Hee Min Yoo, Sung Hwan Kang, Jae Yeon Kim, Joo Eun Lee, Min.
TechKnowTone Contents: Sensor Features Sensor Connections Sample Sketch Questions …Sensor Features… Arduino Coding – Distance Sensors.
Capstone Design 박차영 김동연 설인수.
The GETA Sandals: A Footprint Location Tracking System Kenji Okuda, Shun-yuan Yeh, Chon-in Wu, Keng-hao Chang, and Hao-hua Chu National Taiwan University.
Statistics Describing, Exploring and Comparing Data Chapter 3 Example Problems, Part II.
Wireless Device to Measure Foot Pressure - Selecting Effective Motions to use in the Experiment Team Name : Number Seo Myoung Hyoun
Scientific Process Organized Common Sense. Who uses the Scientific Process? Scientists Anyone trying to solve a problem.
Capstone design Remote manless probe Kim Jinkwang Han Seongkyu.
Capstone Design Middle Evaluation Rover Song Kee Hong Jo Kyeong Jin.
What is the effect of stretching on jumping? Purpose.
Capstone Design Smart CCC ASAP A person doing a presentation JIN GUK KIM.
Guidelines for BME201 Presentation
The Accuracy of the Table Movement During A Whole Body Scan
Effect of factors on PPD synthesis
Usefullness of flow composite image in Raynaud scan(201Tl)
Hak-Jun Lee and Seung-Ki Sul Power Electronics Laboratory
Height and Pressure Test for Improving Spray Application
Development and Test of Simultaneous Power Analysis System for Three-Phase and Four-Wire Power System Hun Oh1, In Ho Ryu2 and Jeong-Chay Jeon3* 1Department.
Table of Contents Governing IT in Higher Education Institutions 1
English Composition: Class 5
Table of Contents Corrosion behavior in AA5754 friction Stir Selded Alloys 1 Filipe Nascimento, Pedro Vilaça, Rosa Miranda, João C.S. Fernandes, Francisco.
Impact Of CMV Reactivation On Relapse In Patients With Acute Leukemia Who Received Allogeneic Stem Cell Transplantation In First Remission: Possible GVL.
MP16-14 CLINICAL IMPLICATION OF METASTASECTOMY IN METACHRONOUS METASTATIC RENAL CELL CARCINOMA IN THE ERA OF TARGETED THERAPY  Jong Won Kim, Jongsoo Lee,
Comparative study on discharge conditions in micro-hole electrical discharge machining of tungsten carbide (WC-Co) material Hyun-Seok TAK 1 , Chang-Seung.
Team 1: 32 responses Team 2: 55 responses Team 3: 29 responses
عمل الطالبة : هايدى محمد عبد المنعم حسين
Improved Outcome of a Reduced Toxicity-Fludarabine, Cyclophosphamide, plus Antithymocyte Globulin Conditioning Regimen for Unrelated Donor Transplantation.
** نظام التعليق الهيدروليكي في السيارات يحول الطاقة الميكانيكية إلى طاقة حرارية.
Repair of Atrial Septal Defect With Eisenmenger Syndrome After Long-Term Sildenafil Therapy  Young-Hwue Kim, MD, PhD, Jeong Jin Yu, MD, PhD, Tae-Jin Yun,
O.
Your topic here Your group list and ID
Diagnostic Application of an Extensive Gene Panel for Leber Congenital Amaurosis with Severe Genetic Heterogeneity  Moon-Woo Seong, Soo Hyun Seo, Young.
Volume 57, Issue 6, Pages (June 2010)
أنماط الإدارة المدرسية وتفويض السلطة الدكتور أشرف الصايغ
Perturbation of Focusing Field Profile due to HV Support Tube
[IEEE P3079 Session #7 WG Closing Plenary]
Comparison of Allogeneic Stem Cell Transplantation from Familial- Mismatched/Haploidentical Donors and from Unrelated Donors in Adults with High-Risk.
Volume 42, Issue 2, Pages (February 2005)
Design and NC Programming
[Draft Document Naming Convention]
[Draft Document Naming Convention]
Large Endobronchial Hamartoma Successfully Resected by Snare Through Flexible Bronchoscopy  Jin Hyoung Kim, MD, Gyeong Min Jeong, MD, Kyung Hye Park,
[Scope of IEEE 3079 standard version 1
The precision test based on states of a Bone Mineral Density
The significance of pulmonary annulus size in the surgical management of transposition of the great arteries with ventricular septal defect and pulmonary.
Presentation transcript:

Creative Capstone Design Development of device to measure side foot pressure for analyzing human walking Team Name : Number Seo Myoung Hyoun Shin Dong Won Lee Seung Jun Lee Jae Min Lee Jeong Eun

Contents Subject Previous papers Experiment Data Analysis Conclusion Q&A 2

Jumping Motion 18persons (39%) Subject 3 Side-step 13persons (28%)

Subject Goal 4 5~10% (existing paper results) Limited Budget Dynamic Motion

5 WARKING & SIDE-step motion Subject

Significance of measuring the lateral pressure Measuring side foot pressure is important to precisely analyze his or her walk Our research can be applied to sports or medical field our team is first to study side pressure 6

Previous Studies 7

8

9 Experiment Experiment equipment 9

10 Experiment Method - Position of sensors

11 Experiment Method - To receive the data by using the Arduino.

12 Experiment Method -Device -Experimenter 1 인 (172cm, 59kg) 1 set 10 번, Total 3 set (30 번 )

13 Experiment Voltage to pressure transferr code  Now we trying to find out CF value Wifi code

14 Data Data Analysis

15 Data Data Analysis

16 Data Data Analysis

17 Data of each point Data Analysis PointAverage (N)Standard deviation Coefficient variation(%) A25.57± B21.30± C3.95± D32.34± E9.88± F109.77±

18 Conclusion 18

19 Conclusion Significance of the experiment 목표했던 CV 값을 만족한 포인트 A, B, D, F ≤15. Future possibility of development 반면 CV 값이 초과된 포인트 (C, E) 는 평균 힘이 10N 미만으로 나왔기 때문에 해당 지점에 압력 측정이 정확히 이루어지지 않았으므로 보완요 망 ABCDEF

Q&A 20