Characterization of the QUartz Photon Intensifying Detector (QUPID) Artin Teymourian UCLA Dark Matter Group Dept. of Physics and Astronomy.

Slides:



Advertisements
Similar presentations
1 Aaron Manalaysay Physik-Institut der Universität Zürich CHIPP 2008 Workshop on Detector R&D June 12, 2008 R&D of Liquid Xenon TPCs for Dark Matter Searches.
Advertisements

for Fusion Power Monitoring
S. Bricola, A. Menegolli, M. Prata, M.C. Prata, G.L. Raselli, M. Rossella, C. Vignoli INFN and University of Pavia - Via Bassi, 6 – Pavia – Italy.
Observation of Fast Scintillation of Cryogenic PbI 2 with VLPCs William W. Moses, 1* W.- Seng Choong, 1 Stephen E. Derenzo, 1 Alan D. Bross, 2 Robert Dysert,
Nustar/crystal simulations B. Genolini Crystal: CsI(Tl) (Saint Gobain), wrapped with reflector (VM2000, Tyveck?) Geometry:
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Crystals and related topics J. Gerl, GSI NUSTAR Calorimeter Working Group Meeting June 17, 2005 Valencia.
GAMMA RAY SPECTROSCOPY
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
J.T. White Texas A&M University SIGN (Scintillation and Ionization in Gaseous Neon) A WIMP Detector based on Gaseous Neon The Future of Dark Matter Detection.
Demonstration and comparison of photomultiplier tubes operation at liquid Argon Temperature Ettore Segreto LNGS (Italy) On behalf of the WArP Collaboration.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Photon detection Visible or near-visible wavelengths
Latest developments in Hamamatsu Large Format PMTs
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
ZEPLIN II Status & ZEPLIN IV Muzaffer Atac David Cline Youngho Seo Franco Sergiampietri Hanguo Wang ULCA ZonEd Proportional scintillation in LIquid Noble.
4/21/2011Katsushi Arisaka, UCLA 1 University of California, Los Angeles Department of Physics and Astronomy Katsushi Arisaka.
1 Max-Planck-Institut fuer Physik, Muenchen, Germany, 2 Humboldt-Universituet Berlin, Germany, 3 Univ. Complutense, Madrid, Spain, 4 ETH, Zurich, Switzerland,
1 The GEM Readout Alternative for XENON Uwe Oberlack Rice University PMT Readout conversion to UV light and proportional multiplication conversion to charge.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
QUPID Readout and Application in Future Noble Liquid Detectors Kevin Lung, UCLA TIPP 2011 June 11, 2011.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Sheffield : R. Hollingworth, D. Tovey R.A.L. : R.Luscher Development of Micromegas charge readout for two phase Xenon based Dark Matter detectors Contents:
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
LOGO The VSiPMT Project Progress in the realization of a larger prototype Felicia Barbato – University of Naples “Federico II” – Italy.
J.T. White Texas A&M University SIGN (Scintillation and Ionization in Gaseous Neon) A High-Pressure, Room- Temperature, Gaseous-Neon-Based Underground.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
F August S. Pordes - Fermilab1 Liquid Argon for Direct Detection of Dark Matter Work and Plans at Fermilab.
DarkSide: a Free Background Experiment Maria Bossa LNGS Seminar IPRD13 Oct 10, 2013.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
1 Liquid Argon Dark Matter: Synergies with R&D for Neutrino Detectors: Chemically clean Argon for drifting electrons and light output (Oxygen and H20 relevant.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Status of the PMT light detection system Gian Luca Raselli 20-AUG-2015 ICARUS executive meeting.
LENA Photosensor R&D Marc Tippmann Lothar Oberauer, Michael Wurm, Gyorgy Korga, Quirin Meindl, Michael Nöbauer, Thurid Mannel, Martin Zeitlmair, German.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Experiment [1] M. Di Marco, P. Peiffer, S. Schonert, LArGe: Background suppression using liquid argon scintillation for 0νββ - decay search with enriched.
Cold PM test at Indiana final measurements, September 9 – 24, 2007 PM under test: Hamamatsu R7725 serial # ZK3692 (tube with Pt underlayer) Hans-Otto Meyer.
May 26-27, 2005Tadashi Nomura (Kyoto U), KRare05 at Frascati, Italy1 Studies on High QE PMT Tadashi Nomura (Kyoto U.) Contents –Motivation –Performance.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
1/27/2016Katsushi Arisaka 1 University of California, Los Angeles Department of Physics and Astronomy Katsushi Arisaka XAX 10.
Latest progress in PMT development VLVnT11 in October, 2011 Hamamatsu Photonics K.K. Electron Tube Division Yuji Hotta.
CMS HF PMT SYSTEM By Y. ONEL U. of Iowa, Iowa City, IA CMS HCAL at Fermilab Feb 6-8, 2003.
Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005.
CMS HF PMT SYSTEM By Y. ONEL U. of Iowa, Iowa City, IA HF-RBX PRR CERN Apr 3-4, 2003.
Characterization of Hamamatsu R12199 PMTs Oleg Kalekin KM3NeT Meeting CPPM, Marseille
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
CaMoO 4 at low temperature - LAAPD and PMTs - Woonku Kang, Jungil Lee, Eunju Jeon, Kyungju Ma, Yeongduk Kim Sejong University for KIMS collaboration Double.
DarkSide LNGS Direct DM Search Using Underground Argon Hanguo Wang, UCLA for the DarkSide Collaboration SJTU, Shanghai May 30,
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
5/13/11 FCPA Mini-RetreatDarkSide - S.Pordes1 DarkSide 10 kg Prototype at Princeton Distillation Column for Depleted Argon at Fermilab DarkSide 50 at Gran.
The Liquid Argon Test Facility in THU Qinghao Chen Tsinghua Univ. CDEX Tuebingen April 9, 2013 Development of High Purity Germanium.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
Development of Multi-Pixel Photon Counters (1)
Study of cryogenic photomultiplier tubes for the future double-phase cryogenic avalanche detector. Budker INP A.Bondar, A.Buzulutskov,A.Dolgov, E.Frolov,
University of South Dakota
Large Area Cryogenic Gaseous Photo Multipliers
XAX Can DM and DBD detectors combined?
New Study for SiPMs Performance in High Electric Field Environment
Recent Progress in Large Format PMTs
Development of hybrid photomultiplier for Hyper-Kamiokande
SoLID EC photonsensor.
PbWO4 Cherenkov light contribution to Hamamatsu S8148 and Zinc Sulfide–Silicon avalanche photodiodes signals F. KOCAK, I. TAPAN Department of Physics,
Presentation transcript:

Characterization of the QUartz Photon Intensifying Detector (QUPID) Artin Teymourian UCLA Dark Matter Group Dept. of Physics and Astronomy

06/10/2011Artin Teymourian, UCLA2

Overview Dual Phase TPC QUPID Concept QUPID Design Goals Test Systems/Results Support Structure Future DM Experiments Conclusion 06/10/20113Artin Teymourian, UCLA

Dual Phase TPC 06/10/20114Artin Teymourian, UCLA

Photo Cathode (-6 kV) APD (0 V) Quartz Al coating APD (0 V) Photo Cathode (-6 kV) Made by Synthetic Silica only. QUPID, The QUartz Photon Intensifying Detector 06/10/20115Artin Teymourian, UCLA

06/10/20116Artin Teymourian, UCLA Actual QUPID

7Artin Teymourian, UCLA06/10/2011 QUPID 3 inch R inch R inch XENON10 XENON100 XMASS LUX DarkSide XENON1T MAX, XAX Comparison of Low-radioactive Photon Detectors from Hamamatsu

QUPID Design Goals 06/10/2011Artin Teymourian, UCLA8 R8520 Radioactivity<4.7 mBq/cm 2 Quantum Efficiency>30% Total Gain>10 6 Pulse Width~10 ns Transit Time Spread~1 ns The QUPID should be better than standard PMTs in all aspects In addition: Photon Counting Capabilities Good Photocathode Uniformity Good Collection Efficiency

Radioactivity PhototubeEffective AreaUnits 238 U 226 Ra 232 Th 40 K 60 Co R cm 2 mBq/cm 2 <2.3<0.056< R MOD 32 cm 2 mBq/cm 2 <2.9<0.076< QUPID32 cm 2 mBq/cm 2 < < /10/20119Artin Teymourian, UCLA arXiv: , arXiv: Radioactivity measured at the Gator screening facility in LNGS, operated by University of Zurich R8520 is a 1” square PMT used in Xenon10 and Xenon100 R11410-MOD is a 3” Circular PMT being considered for future DM detectors The radioactivity of the QUPIDs are far better than the others per unit area 60 Co and 40 K emits  ’s that penetrate particularly far and is of greatest concern for large DM detectors

Quantum Efficiency Data taken at Hamamatsu Photocathode developed specifically for operation in Xenon >30% QE at 178 nm, the scintillation wavelength of Xenon 06/10/201110Artin Teymourian, UCLA

Argon and Xenon Versions of the QUPID 06/10/2011Artin Teymourian, UCLA11 The photocathode can be optimized for Argon operation, quartz is not transparent to Argon scintillation wavelength, so a WLS must be used to bring it to visible wavelengths The Quantum Efficiency of the Argon version peaks at ~40% near 400 nm TPB can be used to wavelength shift Ar scintillation light to the visible wavelengths Data taken at Hamamatsu

DC Cathode Linearity Data taken at Hamamatsu Photocathode also developed to withstand low temperatures with good linearity At Liquid Xenon temperature, the photocathode is linear up to >1  A 06/10/201112Artin Teymourian, UCLA

Liquid Nitrogen Cooling System 06/10/201113Artin Teymourian, UCLA

Readout Schematic 06/10/2011Artin Teymourian, UCLA14

Leakage Current Strong temperature dependence of Leakage Current Want to operate before breakdown to maximize gain 06/10/201115Artin Teymourian, UCLA

Leakage Current for Argon Operation 06/10/2011Artin Teymourian, UCLA16 Xenon Argon APD is inoperative below 120V bias At liquid xenon temperatures, the APD is still operative APD for liquid argon operation has been developed by Hamamatsu and is being integrated in the QUPID for Liquid argon temperature

Avalanche and Bombardment Gain Avalanche GainBombardment Gain Avalanche Gain shows strong temperature dependence, Bombardment Gain does not Maximum Avalanche Gain ~200, maximum Bombardment Gain ~750 Total Gain ~ /10/201117Artin Teymourian, UCLA

Photon Counting Capabilities and Pulse Shape ns Rise time1.8 ± 0.1 Fall time2.5 ± 0.2 Pulse width4.20 ± 0.05 Transit time spread0.16 ± /10/201118Artin Teymourian, UCLA

06/10/2011Artin Teymourian, UCLA19 -6 kV -8 kV A new version of the QUPID is being made Operation will be possible up to -8 kV Much better photon counting is possible Data taken at Hamamatsu

Preliminary -8 kV Operation 06/10/2011Artin Teymourian, UCLA20 Data taken at Hamamatsu

Uniformity System Optical Fiber and Focusing Lens QUPID Phi AxisTheta Axis 06/10/201121Artin Teymourian, UCLA

Uniformity Photocathode UniformityCollection Efficiency Uniform photocathode response (within 20%) and collection efficiency 06/10/201122Artin Teymourian, UCLA

QUPID Characteristics Summary 06/10/201123Artin Teymourian, UCLA R8520QUPID Radioactivity<4.7 mBq/cm 2 <0.59 mBq/cm 2 Quantum Efficiency>30%>30% at 178nm Photocathode -100 o C 0.1 nA >1  A Total Gain>10 6 >10 5 (>10 6 with amplifier) APD Leakage Current---<1 nA at -100 o C Pulse Width~10 ns4.2 ns Transit Time Spread~1 ns160 ps 1, 2, 3 photoelectron peaks seen clearly Good photocathode uniformity Excellent collection efficiency over the entire photocathode

Operation in Liquid Xenon 06/10/2011Artin Teymourian, UCLA24

Single QUPID Holder -6 kV Contact Ti Clips for Support and Ground PTFE Holder for Contacts Copper Plate 06/10/201125Artin Teymourian, UCLA

06/10/201126Artin Teymourian, UCLA

06/10/201127Artin Teymourian, UCLA

06/10/2011Artin Teymourian, UCLA28 QUPID Operation in Liquid Xenon

Scintillation Light of Xenon Observed 06/10/201129Artin Teymourian, UCLA 122 keV  2.0 pe/keV 5.3 MeV  1.6 pe/keV

7 QUPID Holder PTFE Reflectors 7-QUPID Support 06/10/201130Artin Teymourian, UCLA

06/10/201131Artin Teymourian, UCLA

Future Detectors 06/10/201132Artin Teymourian, UCLA DarkSide50 Xenon1Ton

Conclusion QUPIDs are a new, low radioactivity phototube for future DM experiments Excellent photon counting, uniformity, quantum efficiency, and photocathode linearity Has been operated in cryogenic temperatures and in Liquid Xenon, with scintillation light being observed Will be used in DarkSide50 and Xenon1Ton 06/10/201133Artin Teymourian, UCLA

Acknowledgements XENON100 Collaboration DarkSide50 Collaboration MAX Collaboration Hamamatsu Photonics “Characterization of the QUartz Photon Intensifying Detector (QUPID) for use in Noble Liquid Detectors” arXiv: “Material screening and selection for XENON100” arXiv: /10/2011Artin Teymourian, UCLA34

Extra Slides 06/10/2011Artin Teymourian, UCLA35

Scintillation Light of Xenon Observed 06/10/201136Artin Teymourian, UCLA 122 keV  2.0 pe/keV 5.3 MeV  1.6 pe/keV

Published Decay Times 06/10/2011Artin Teymourian, UCLA37 Hitachi, et al. The values for the decay times and proportion of fast and slow components are comparable to published values

Scintillation Characteristics SourceTypeEneryLight YieldResolutionDecay TimePreviously Published Decay Times 57 Co  122 keV, 86% 136 keV, 11% 2.0 ± 0.2 pe/keV10.4 ± 1.2%39.1 ± 0.2 ns 34 ± 2 ns (Kubota, et al.) 45 ns (Hitachi, et al.) 210 Po  5.3 MeV1.6 ± 0.2 pe/keV2.5 ± 0.5% 4.5 ± 0.1 ns, fast (71%) 26.4 ± 0.4 ns, slow (29%) 4.3 ± 0.6 ns, fast (69%) 22.0 ± 2.0 ns, slow (31%) (Hitachi, et al.) 38Artin Teymourian, UCLA06/10/2011

DC Cathode Linearity Data taken at Hamamatsu QUPID photocathode 4 orders of magnitude better in linearity 06/10/201139Artin Teymourian, UCLA

Linearity System 06/10/2011Artin Teymourian, UCLA40 Continuous Filter Wheel Discrete Filter Wheel LED Fiber to QUPID Control Motors

Anode Linearity Anode linear up to ~2 mA at 10 5 gain Anode linearity independent of temperature Gradual non-linearity can be characterized and applied as a correction 06/10/201141Artin Teymourian, UCLA