IPD Technical Conference February 19 th 2008 Flat Ribbon Cable Ends.

Slides:



Advertisements
Similar presentations
Minimizing Micro-Cracks in Solar Cell Interconnections Paul Wood Advanced Product Applications Manager.
Advertisements

(GET FAMILIAR WITH EQUIPMENT)
1 VITROVEX ® glass products Nautilus Marine Service GmbH based in Bremen (Germany) Manufacture of VITROVEX® glass products used as pressure resistant housings.
RMS VISION SYSTEMS Innovative Solutions for the Semiconductor Industry Application Note: CD Measurement for FET Features NGS 3500 Advanced Metrology System.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
Pore Detection in Small Diameter Bores The University of Michigan, Ann Arbor NSF Engineering Research Center for Reconfigurable Manufacturing Systems.
Spacecraft Stereo Imaging Systems Group S3. Variables Separation of the cameras Height of the cameras – relative to the bench Angle – The direction cameras.
Camera Calibration CS485/685 Computer Vision Prof. Bebis.
Technical Working Group 3: Flexible Manufacturing February 18, 2014 Ron Brown Technology Leader.
Algorithm Optimization for Swept Source Fourier Domain Optical Coherence Tomography (OCT) with Galvo Scanner and Digital Signal Processor (DSP) Kevin Seekell.
TESTING MULTIMODE FIBER
Decimals, Fractions, and Percents. Definitions Decimal - Any number shown with a decimal point; a number based upon tenths or hundredths. ( 0.2, 0.375,
Chapter 9 Numerical Integration Numerical Integration Application: Normal Distributions Copyright © The McGraw-Hill Companies, Inc. Permission required.
On the Design, Construction and Operation of a Diffraction Rangefinder MS Thesis Presentation Gino Lopes A Thesis submitted to the Graduate Faculty of.
MICE Radiation Shield Installation 1 18 th October2012 Summary of initial test N. Collomb.
Instrumentation and Measurements
CT Quality Control for CT Scanners. Quality Control in CT A good idea? Yes Required for accreditation? Sometimes Improves image quality? Sometimes Depends.
IPD Technical Conference February 19 th 2008 Cable Disk Inspection.
Feasibility of Optical Wireless transmission systems for CTA R. Corsini, A. Wajahat, E. Ciaramella Scuola Superiore Sant’Anna, TeCP, Pisa, Italy R. Paoletti.
Producing Valid Results (Risk Mitigation and Measurement Assurance)
IPD Technical Conference February 19 th 2008 New Processors in Sherlock 7 Ben Dawson.
Department of Bioengineering FAILURE ENERGY: COMPARING SUTURE PERFORMANCE UNDER UNIAXIAL TENSION GROUP 101B1 Alison Agres – Background & Objective Ted.
Integrated Vision Solutions A World of Material Handling Solutions.
IPD Technical Conference February 19 th 2008 Automotive Fuse Box Inspection.
IPD Technical Conference February 19 th 2008 SNAP RING DIMENSION VERIFICATION.
MODERN SURVEY (FAMILARISATION WITH EQUIPMENTS). Modern equipments EDM – Electronic distance measurement eqp. EDM – Electronic distance measurement eqp.
SS5305 – Motion Capture Initialization 1. Objectives Camera Setup Data Capture using a Single Camera Data Capture using two Cameras Calibration Calibration.
IPD Technical Conference February 19 th 2008 Friction Roller Identification Jack Weatherford Hermitage Automation & Controls.
IPD Technical Conference February 19 th 2008 Application: Juice Box Web Slitting Application – Monitor and Verify Crease to Knife Cut Edge Position. Distributor:
Photogrammetry for Large Structures M. Kesteven CASS, CSIRO From Antikythera to the SKA Kerastari Workshop, June
IPD Technical Conference February 19 th 2008 Automotive Chain Inspection.
NIRSpec Operations Concept Michael Regan(STScI), Jeff Valenti (STScI) Wolfram Freduling(ECF), Harald Kuntschner(ECF), Robert Fosbury (ECF)
Zone Plate Testing at 1-BM-B Preliminary Results Michael J. Wojcik, Shashidhara Marathe, Naresh Gandhi Kujala,
Instrumentation and Measurements Class 3 Instrument Performance Characteristics.
Feng-Xiang Huang Test Symposium(ETS), th IEEE European Ko, Ho Fai; Nicolici, Nicola; Department of Electrical and Computer Engineering,
Computer Vision : CISC 4/689 Going Back a little Cameras.ppt.
NestedLoops-Mody7-part51 Two-Dimensional Arrays and Nested Loops – part 5 Rotations Barb Ericson Georgia Institute of Technology May 2007.
IPD Technical Conference February 19 th 2008 Application: Pipette Measurement and Flash Inspection. Distributor: CPU Automation Engineer: Mike Bray.
3d Pose Detection Used by Kinect
High Speed 3D Imaging Technology
高精度高速度的三维测量技术. 3D stereo camera Stereo line scan camera 3D data and color image simultaneously 3D-PIXA.
Digital Cameras Computer Multimedia. Digital Cameras The major factor in a digital camera is the megapixel rating. The resolution of a digital image is.
Inspection- “back-end quality control” BUT, Start by designing quality into the front end of the process- the design QFD (Quality Function Deployment)
Barcodes, MMS, and the Internet’s Cheapest Prices Greg McGrath & Greg Maier Advisors: Professor Cotter, Professor Rudko ECE-499 March 01, 2008.
NIRISS NRM bad pixel tolerance analysis David Lafrenière 2012 February 21.
HTML Frames. Advantages to Using Frames n flexibility in design n information in different Web pages n remove redundancy. n site easier to manage. n update.
Quality Control Bushong Chapter 10.
1 Stellarator Core Metrology issues NCSX WBS-1 Meeting April 2, 2003 What are we measuring? When? How do we take the measurements? How do we correlate.
Part of a set or part of a whole. 3 4 =Numerator the number of parts = Denominator the number that equals the whole.
C.BAULT November 9 th  LAYOUT STRAWMAN 07V13 Vs STRAWMAN 07V14  SERVICES AND STRUCTURES INVENTORY  ENVELOPE SERVICES  BARREL SERVICES ROUTING.
Lecture 8: Measurement Errors 1. Objectives List some sources of measurement errors. Classify measurement errors into systematic and random errors. Study.
IPD Technical Conference February 19 th 2008 Packing Inspection.
IPD Technical Conference February 19 th 2008 Tire Material Inspection.
IPD Technical Conference February 19 th 2008 Sherlock Future developments.
Copyright © Cengage Learning. All rights reserved.
From: An Automated Reference Frame Selection (ARFS) Algorithm for Cone Imaging with Adaptive Optics Scanning Light Ophthalmoscopy Trans. Vis. Sci. Tech..
Decimals, Fractions, and Percents
Approximate the area of the shaded region under the graph of the given function by using the indicated rectangles. (The rectangles have equal width.) {image}
Image Analysis Image Restoration.
Lock fixed scale vernier scale Vernier Caliper jaws.
ASPECT RATIOS IN PROJECTION SYSTEMS
Fits for Pinhole and FresnelZonePlate
Order of Operations and Evaluating Expressions
Section 7.5: Review.
Local Habitat Sampling
The Image The pixels in the image The mask The resulting image 255 X
Tolerance Tolerance is the amount of error that is allowed when manufacturing a product. Very small differences are allowed in products because different.
Mounting & Alignment Malcolm Guthrie
Alignment, Scanning Malcolm Guthrie
Turn to page 30 in the Airframe & Power plant Mechanics general handbook.
Presentation transcript:

IPD Technical Conference February 19 th 2008 Flat Ribbon Cable Ends

The Product  Company X manufactures flat ribbon cables and connectors.  The cable ends must meet extremely high tolerance requirements – hundredths of millimeters – to ensure that when they are mated with connectors, the conductors in the cable ends mate with the pins in the connectors.

Inspection Requirement Typical measurements Width: mm Span: mm Left stripping: 4.98 mm Right stripping: 4.96 mm

Inspection Requirement  Currently, inspection of the cable ends on randomly-selected cables is performed with an optical comparator. This approach is highly subjective.  The measurements must be automated. (Inspection is still performed on a sample of cables; 100% inspection is not a requirement.)

Prototype System  A cable is inserted into an inspection station that constrains the position of the cable end within the field of view of a high-resolution camera. (In a 1376 x 1035 image, each pixel equals about 0.02 mm.)  The cable is back-lighted.

Prototype System Various Sherlock ROIs and algorithms are applied to make the measurements.

Problems Because the measurement tolerances are so strict, vibration or movement of the camera can throw off a “static” calibration and result in bad readings. Therefore, Sherlock must be recalibrated on every image acquisition… BUT, the integrator assumes that the cable being inspected meets the manufacturing specification for “average width”, and uses this as the calibration target.

Solution: Calibrate on every image using a calibration target of a known size

30 mm-wide calibration bar Line ROI executing Inside Caliper algorithm

Calibration bar width (pixels) Calibration bar width (mm) mm/pixel (Instance of Numeric : Divide)

Test Results Cumulative results from three sets of images of the same cable end. Within each set of about 20 images, the cable is stationary; this is a test of Sherlock's measurement repeatability on the "same" image. From image set to image set, the cable was moved slightly; this is a test of Sherlock's measurement repeatability on the same part in different positions.