Herzlich Willkommen Bienvenue Welcome JUMO Analytical Measurement.

Slides:



Advertisements
Similar presentations
Welcome Herzlich Willkommen Bienvenue JUMO eTRON T data sheet
Advertisements

HUMIDIFICATION/COOLING TOWER
City Water Equipment Introduction Applications Features Installation draw.
Inductive Capacitive Optical Infrared Flow Temperature Sensors for Automation.
File Name: Conductivity.pptFeb 2001 Conductivity Theory Applied to Proper Hardware Selection.
Packaging Materials An overview. Main Packaging Materials  Metals  Paper and Board  Glass  Polymers This session will concentrate on the first three.
Objective of the session.
Dynamic Behavior of Closed-Loop Control Systems Chapter 9.
So Far: Conservation of Mass and Energy Pressure Drop in Pipes Flow Measurement Instruments Flow Control (Valves) Types of Pumps and Pump Sizing This Week:
Specific latent heat and radiation What is specific latent heat????? This is the energy absorbed or released when a substance changes state or phase.
UR24 Process Refractometer
Drug Delivery & Tissue Engineering Laboratory
HEAT EXCHANGERS in food process engineering Energy balance methodology used to design industrial equipments 1 FIP-DES Bertrand Broyart, Violaine Athès.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
Fundamental Techniques and Measurements  Mass Measurements  Volume Measurements  Preparation of a solution of known concentration  UV-Visible Spectrophotometer.
Instrumentation: ground and noise Temperature Measurement.
AD monitoring March, Applying CCD(CMOS) Measuring Methods 1. Liquid Level Detection 1.1 Applying CCD(CMOS) Measuring Methods (1)
Mitigation. Energy efficiency, is using less energy to provide the same level of energy service.
Control System Instrumentation
POLUTED WATER WITH OIL HYDROCARBONS, METALS, SALTS, CHEMICALS... Emulsion = Water + Concentrate.
pH and Conductivity Best Practices
„ Save Energy and Resources with BRAUMAT Analysis and Options.
PURECHLOR – System, Service, Reagents & BOOM. Chlorine dioxide What is Chlorine Dioxide (ClO 2 )? A powerful biocide Consists of 1 atom of Chlorine, 2.
IGCSE ICT Control.
JC Equipments Pvt. Ltd Heat Exchanger Manufacturers Off Ph : , Tele Fax :
Alfa Laval Group Presentation Alfa Laval is a leading global provider of specialized products and engineered solutions. The company.
HEAT EXCHANGER.
INTRODUCTION Definition:
24.1 – How Solutions Form.  Same composition, color, density and taste throughout  Homogenous mixture  Exist in all states of matter  The air we breathe.
Herzlich Willkommen Bienvenue Welcome JUMO eTRON M 100 according to data sheet Electronic 2-channel microstat Klaus Otto.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Solid Applied Technologies Gauger Compact, continuous, non-contact, loop- powered, ultrasonic level meter: Simple installation and configuration.
FLUID SYSTEMS Ecomax Industries: Plot No. F - 31, Ranjangaon MIDC
Control System Instrumentation
Reinhard Manns / PL20 1 JUMO CTI-500 PL20 Analytical measurment systems.
Experts in Chem-Feed and Water Treatment Where Are The Opportunities & What Are The Applications.
PL-ELS 2100 Ice. PL-ELS 2100 Ice Evaporation at Sub Ambient Temperatures The PL-ELS 2100 Ice comprises an Integrated Cooled Evaporator in combination.
Thermocouples (continued) Introduction to Temperature Sensors ISAT 300 Instrumentation and Measurement 02/21/2000.
Chapter 11 Heat Exchangers ( ) Heat Exchangers.
Water. What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured application software.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
Temperature Measurement. List methods of temperature measurement / equipment.
Professor: Eduardo Cabrera Thermal Engineering Laboratory
Programmable Controllers - ECL/ECB
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 11 Heat Exchangers.
Manufacturing Process of H3PO4 (wet process)
Hot Disk Transient Plane Source (TPS) Technique
Photo size is: Versatronic
Measuring device to test completely installed insulated rail joints safely and contactless with direct resistance indication.
Applied to Proper Hardware Selection
Government Engineering College
Control System Instrumentation
Integrated Instrumentation Solutions
Copyright SwissFlow B.V.
Boiler System Make-up Water Primary Secondary Pretreatment
Industrial Instrumentation: Transmitters
T7 – POLYPROPYLENE PLEATED CARTRIDGES
“Desuperheater” High Efficient Energy conservation Device for Refrigeration Use
Desuperheater Best Heat Transfer Device Used In Various Industries
Concentric Tube (double-pipe) Heat Exchangers
Control System Instrumentation
Control System Instrumentation
Closed loop cooling system Cooling tower
Fundamental Techniques and Measurements
Heat Exchangers Heat Exchangers.
The perfect fit for corrosive wet areas Maintenance Units, Series MH1
Presentation transcript:

Herzlich Willkommen Bienvenue Welcome JUMO Analytical Measurement

2 PL 20 RM JUMO CTI-750 Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts 1 Applications 2 Outer Features 3 Inner Features 4 Application Example CIP 5 Timetable

3 PL 20 RM 1 Applications – Food-, Beverages- and Pharmaceutical Industry, Breweries and Dairies – Product control (Phase separation Product/Product mixture/Water) – Control (e.g. Phase separation Detergent/Dishwater) of cleaning processes e.g. bottle cleaning plants and container cleaning

4 PL 20 RM – Concentration control of acids and bases e.g. in electroplating and chemical processing plants – CIP-systems e.g. Control and balance of concentration in Acids / Bases – Water- and Wastewater engineering e.g. process water control – Dosing of chemicals – Leakage indication in separated loops, e.g. in heating- and cooling plants 1 Applications

5 PL 20 RM 2 Outer Features – Instrument version Head transmitter Compact unit Available as well without display/keypad (for suppliers with an appropriate own control)

6 PL 20 RM 2 Outer Features – Instrument versions Transmitter with separate sensor e.g. for application fields with strong vibrations and significant heat radiation Available as well without display/keypad (for suppliers with an appropriate own control)

7 PL 20 RM 2 Outer Features – Graphic display Clear text operating (operating possible„without“ manual) Operating languages – German – English – French – Polish – Spanish Background illumination (enables operation in badly lit surroundings) Top cover turnable

8 PL 20 RM 2 Outer Features

9 PL 20 RM 2 Outer Features – Sensor material PEEK (Polyetheretherketon) General resistent material – light mineral acids (e.g. Hydrochloric acid) – light organic acids (e.g. Lactic acid) – bases (e.g. caustic soda) – oxidising acid (e.g. nitric acid) <30 weight %) max. temperature 140°C (sterilisation) e.g. Approvals for food (FDA listed) – Fast-response temperature sensor

10 PL 20 RM – Please ask for versions with inside temperature sensor ! Some liquids affect steels (e.g. chromate) – Elektrical connection Cable bushing M12 plug connections (if necessary, a mechanist can exchange the device) 2 Outer Features

11 PL 20 RM – Two analogue actual value outputs (galvanic insulation; freely programmable) Conductivity / Concentration Temperature – Two switching outputs (AC/DC V; 200mA) Galvanic insulation 3 Key features

12 PL 20 RM – Activation of up to four ranges and up to four temperature coefficients Application in CIP-systems Here up to four media must be registered correctly 3 Key Features

13 PL 20 RM – Activation of four ranges and temperature coefficients Range 1Product e.g. milk Range 2Cleaning solution 1 (base) Range 3Cleaning solution 2 (acid) Range 4Cleaning with water Each medium has „its own “ temperature coefficient and „its own“ conductivity (range). 3 Key Functions

14 PL 20 RM – Concentration measurement (reservoir of cleaning solutions e.g. in bottle cleaning plants and CIP systems) Caustic Soda (preassigned) Nitric acid (preassigned) Freely definable curve - programmable with Setup program – Own cleaning media – Learning function for non-linear temperatur coefficients – Special liquids 3 Key Features

15 PL 20 RM – Dilution control (please refer to JUMO CTI-500) Application in wet cooling towers Integrated flowing off control, which can control the dilution and the additon of biocide. – With two tasks: Evaporation / Balancing of densification Water treatment 3 Key Features