Presented to: By: Date: Federal Aviation Administration Engine Nacelle Halon Replacement International Aircraft Systems Fire Protection Working Group Mr.

Slides:



Advertisements
Similar presentations
Fired And Unfired Pressure Vessels
Advertisements

Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center
Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center
BRIEF OVER VIEW OF THE MINIMUM PERFORMANCE STANDARD FOR ENGINES describes geometry for a fixture loosely representing an aircraft engine nacelle describes.
Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration.
Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, AAR-440 Bldg.
Recent Simulator Activity Baseline Testing –Fire testing performed during the first week of May 2000 –Agent testing performed during the third and fourth.
Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration.
Presented to: By: Date: Federal Aviation Administration International Aircraft Materials Fire Test Working Group Developing an In-flight Fire Condition.
Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, AAR-440 Bldg.
William Cavage AAR-440 Fire Safety Branch Wm. J
LITHIUM BATTERY FIRE TESTS Harry Webster FAA William J Hughes Technical Center
Design Steps : Furnace Of A Steam Generator P M V Subbarao Professor Mechanical Engineering Department Selection of Geometric Parameters….
Aircraft Cargo Compartment Fire Detection
Halon Systems Ch. 5, pages HALogenated hydrocarbON not the same as halogen F, Cl, Br, I 1940’s ’s extremely effective.
Presented to: By: Date: Federal Aviation Administration International Aircraft Materials Fire Test Working Group Meeting Task Group Session on Revised.
Preamble to Slide Series. “Fire is no Accident” Fire Chemistry for Construction Workers.
Jet-A Vaporization In an Experimental Tank Part II: Experimental Results at Atmospheric and Sub-Atmospheric Pressures Robert Ian Ochs Rutgers, The State.
Welding, Cutting, & Burning. GENERAL HAZARDS General hazards of welding include: –Impact –Penetration –Harmful dust –Smoke –Fumes –Heat –Light radiation.
Cargo Bay Fire Protection with a Fuel Tank Inerting System William Cavage AAR-440 Fire Safety Branch Wm. J. Hughes Technical Center Federal Aviation Administration.
Limiting Oxygen Concentration of Aviation Fuels Federal Aviation Administration 0 0 Limiting Oxygen Concentration of Aviation Fuels Steve Summer Project.
1 Fire Safety Emergency Preparedness Session 10 Laboratory Safety Training.
Firefighter I. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used with permission. 2 Copyright and.
By: Dirk Patrick Cloete
State of the Art of Fuel Tank Ullage Oxygen Concentration Measurement William Cavage AAR-440 Fire Safety Branch Wm. J. Hughes Technical Center Federal.
In today’s global business environment, the need for clean agent fire suppression has never been greater. Pem All.
Class C Cargo Compartment ULD Suppression Agent Penetration Test
FIREPROOF AND FIRE RESISTANT MATERIALS Federal Aviation Administration Project Manager: J. Reinhardt William J. Hughes Technical Center Airport and Aircraft.
Engine Nacelle Halon Replacement, FAA WJ Hughes Technical Center Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration.
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
NEXT GENERATION Kidde Engineered Fire Suppression System Designed for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Federal Aviation Administration 0 Composite Wing Tank Flammability April 2-3, Composite and Aluminum Wing Tank Flammability Comparison Testing Steve.
ALTERNATIVE AGENT UPDATE Louise C. Speitel Fire Safety Branch AAR-440 FAA W.J. Hughes Technical Center Atlantic City International Airport, NJ
Federal Aviation Administration Status of Research & Testing to Replace Halon Extinguishing Agents in Civil Aviation Fire Safety Team FAA Wm. J. Hughes.
Presented to: International Aircraft Systems Fire Protection Working Group. Atlantic City, NJ By: Dave Blake. FAA Technical Center. Atlantic City, NJ.
FIRE BEHAVIOR State of Georgia BASIC FIRE FIGHTER TRAINING COURSE Module 1.
Presented to: By: Date: Federal Aviation Administration Forced-flow Fire Testing with “cold”-soaked FK International Aircraft Systems Fire Protection.
Federal Aviation Administration Handheld Advisory Circular Update Louise Speitel Fire Safety Branch FAA Wm. J. Hughes Technical Center Atlantic City International.
Using Thermal Energy Chapter 6 Notes. Thermal Energy on the “Moo”ve Conduction- transfer of energy by direct contact of particles Convection- transfer.
Federal Aviation Administration Radiant Panel Test for Thermal/Acoustic Insulation 0 Federal Aviation Administration International Aircraft Materials Fire.
Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration.
Federal Aviation Administration COMPOSITE MATERIAL FIRE FIGHTING Presented to: International Aircraft Materials Fire Test Working Group Atlantic City,
Reticulated Foam Advantages: 100% protection Passive System
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
NexGen Fire Test Burner Update
Presented to: IAMFTWG, Renton, WA By: Robert Ochs Date: March 3, 2010 Federal Aviation Administration NexGen Burner for Seat Cushion Fire Testing.
Tim Marker Discussion of Burner Heat Flux Mapping for Proposed Insulation Burnthrough Test Standard FAA Technical Center.
Cargo Bay Fire Protection with a Fuel Tank Inerting System
Federal Aviation Administration Halon 1211 Stratification/ Localization in Aircraft Louise Speitel Fire Safety Branch FAA Wm. J. Hughes Technical Center.
Federal Aviation Administration 0 Composite Wing Tank Flammability November 20, Composite and Aluminum Wing Tank Flammability Comparison Testing.
Jet Fuel Vaporization and Condensation: Modeling and Validation Robert Ochs and C.E. Polymeropoulos Rutgers, The State University of New Jersey International.
Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, ATO-P (formerly.
Combustion Calculations Calculate the theoretical flame temperature of combustion of hydrogen with theoretical amount of air assuming (a)No dissociation.
Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, AAR-440 Bldg.
Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration.
Energy & Heat Energy – ability to produce heat Heat - energy in the process of flowing from a warmer object to a cooler object. In chemical reactions.
Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, AJP6320 Bldg.
Federal Aviation Administration 0 Composite Wing Tank Flammability May 19 th, Composite and Aluminum Wing Tank Flammability Comparison Testing Steve.
Federal Aviation Administration Status of Research & Testing to Replace Halon Extinguishing Agents in Civil Aviation Douglas Ingerson Louise Speitel Constantine.
Presented to: By: Date: Federal Aviation Administration International Aircraft Materials Fire Test Working Group Meeting Task Group Session on Revised.
IASFPWG – Atlantic City, NJ Limiting Oxygen Concentration (LOC) Work Update International Aircraft Systems Fire Protection Working Group Atlantic.
Aircraft Cargo Compartment Fire Detector Certification. David Blake FAA Technical Center Atlantic City, NJ 3 rd Triennial International Fire and Cabin.
The Fuel Tank Flammability Assessment Method November 2, 2005 Federal Aviation Administration 0 0 The Fuel Tank Flammability Assessment Method Steve Summer.
Presented to: International Aircraft Systems Fire Protection Working Group. London, UK By: Dave Blake. FAA Technical Center. Atlantic City, NJ.
Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center Point of Contact :Doug Ingerson Department of Transportation Federal Aviation Administration.
Presented to: By: Date: Federal Aviation Administration Engine Nacelle Halon Replacement International Aircraft Systems Fire Protection Working Group Douglas.
Wing Tank Flammability Testing William Cavage Steven Summer AAR-440 Fire Safety Branch Wm. J. Hughes Technical Center Federal Aviation Administration International.
Presented to: International Aircraft Materials Fire Test Working Group By: Robert Ochs Date: Wednesday, October 21, 2009 Federal Aviation Administration.
Fire Behavior & Extinguisher Use.
Portable Fire Extinguisher Overview
Presentation transcript:

Presented to: By: Date: Federal Aviation Administration Engine Nacelle Halon Replacement International Aircraft Systems Fire Protection Working Group Mr. Richard Hill for Douglas Ingerson, Engineer Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch Atlantic City Int’l Airport, NJ USA tel : April2007

2 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Presentation Overview Review Equivalent Concentrations for HFC-125, CF3I, and FK Alterations/Embellishments to the Minimum Performance Standard for Engine Nacelles and APU Compartments (MPSe) –Move away from a Halon 1301 Benchmark –Considerations for atypical fire extinguishing agents

3 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Equivalent Concentrations, HFC-125, CF3I, FK Based on work completed in the FAA Technical Center’s nacelle fire simulator in accordance with the MPSe Calculated values exceed cup burner data and intermingle with inerting data

4 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Equivalent Concentrations, HFC-125, CF3I, FK

5 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Move the MPSe off a Halon 1301 Benchmark Why ? –Halon 1301 supplies diminishing –continued discharge to atmosphere SPECIFIED for testing purposes –need to move forward How ? –specify another fire extinguishing agent as the benchmark –specify the combustion threats –other ?

6 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Move the MPSe off a Halon 1301 Benchmark Specify another fire extinguishing agent as the benchmark –HFC-125 Pro’s –compares physically to Halon 1301 better than common choices –established work with this agent already exists within aviation –widely used outside aviation as a halon replacement candidate Con’s –global warmer –increased mass required to equate to Halon 1301 performance –CF3I : no forecasted use by working group members; currently not considered a possibility for this issue

7 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Move the MPSe off a Halon 1301 Benchmark Specify another fire extinguishing agent as the benchmark (continued) –FK Pro’s –not a global warmer –wide use as a halon replacement being established outside aviation Con’s –physically dissimilar to Halon 1301 –increased mass required to equate to Halon 1301 performance –lesser work established within aviation –other suggestion ?

8 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Move the MPSe off a Halon 1301 Benchmark Specify the combustion threats –During early developmental history of the MPSe, task group opted NOT to do this complex test environment; i.e. aerodynamically dependent, flame holding, electrical arcs, hot surfaces, ignition behaviors, fuel/air diffusion behavior, etc. observed/measured the fire extinction performance of Halon 1301 and forced a candidate to replicate the established performance –fire threat intensity affirmed by delivering “half-certification” Halon 1301 and verifying no fire extinction –negated specifying by heat flux, temperature profile, geometries, fuel flows, etc.

9 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Move the MPSe off a Halon 1301 Benchmark Specify the combustion threats (continued) –HOWEVER, this offers another path to remove the specification of Halon 1301 from the MPSe need to specify : –fuel types, initial fuel temperature, flow rates, fuel spray patterns, etc. –energy release of the fire threat; i.e. heat flux, temperature –geometries of the fire threat; i.e. flame holders, hot surface(s) –ventilated pathway of the structure some of this specification already exists in the MPSe principle focus for additional thought/work/specification are the fire threats themselves

10 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Move the MPSe off a Halon 1301 Benchmark Other possibilities to remove the Halon 1301 benchmark ?

11 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Considerations for atypical replacement candidates MPSe is written with sections reserved to allow for atypical replacement candidates These sections are currently unspecified Potential examples : –agents delivered as liquid or solid aerosols; i.e. particles –active or inert gas generators; i.e. gases and particles –hybrids; clean agents sitting atop an inert gas generator

12 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Considerations for atypical replacement candidates Current state of the art for civil aviation is clean, gaseous agents The entire certification process is dependent upon the current state of the art Atypical candidates will require alternate means of measurement to demonstrate acceptable behavior

13 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Considerations for atypical replacement candidates How should atypical agent quantification be handled in the MPSe ? –Statham-derivative gas analyzers are written into the MPSe due to common availability and historical stature –no means to measure aerosols is recognized by the FAA –no means to measure products from inert gas generators is recognized by the FAA two major decomposition products are H 2 O(g) and N 2 Statham-derivative analyzers : –can not measure N 2 concentration –have no history of measuring water vapor »early reports indicate sensitivity to atmospheric humidity »however, potentially insufficient sensitivity

14 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Considerations for atypical replacement candidates How should atypical agent quantification be handled in the MPSe ? (continued) –if an applicant pursues an atypical agent pathway : they will be required, by default, to develop/prove their own measurement method and equipment what is the impact on the MPSe as a result ? –incorporate new words in the reserved sections about the atypical agent and measurement procedure; in essence, specify agent and applicant in the MPSe –remove details from the MPSe regarding the Statham-derivative analyzers and their applicability to clean agents »by doing so, negates the need to specify atypical agent details »could place ambiguous wording to ensure an adequate measurement process is followed

15 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Considerations for atypical replacement candidates Impact on the assessment of the reignition time delay (RTD) –RTD = time (fire reignition) – time (fire extinction) agent pulse moves through ventilated test fixture persistent fuel and ignition sources force reignition after agent pulse degrades sufficiently –due to the use of clean agents, the RTD is a reasonably visiual determination from video tape; is specified so in the MPSe –atypical agents may obscure visibility change the specification in the MPSe to permit alternate means ? should the specification change be “tight”/exact or ambiguous ?

16 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Alterations to the MPSe Considerations for atypical replacement candidates Impact on the assessment of the reignition time delay (RTD) (continued) –historical work indicates the use of a fine-bead thermocouple is inexact as compared to visual indication thermal response too slow thermocouple bead location is very important –alternate considerations track energy output from the obscured volume surrounding the flame –obscured cloud temperature should change obviously based on the lack or presence of energy (flames) internal to the cloud –absorption/reflection/transmission characteristics of the cloud are likely unknowns use a Gardon gage style heat flux transducer other ?

17 Federal Aviation Administration IASFP Working Group Meeting, London, England 16-17April Concluding Summary Equivalent concentrations –HFC-125 = 17.6%v/v –CF3I = 7.1%v/v –FK = 6.1%v/v Engine task group members please consider impacts to the MPSe due to : –replacing the Halon 1301 benchmark with another reference –atypical Halon 1301 replacement agents : whether or not to specify individual analytical measurement methods how to asses the RTD by non-visual means –comments to be solicited in the “near” future