MuTRG Channel map summary June 30, 2008 Tsutomu Mibe KEK 1
Octant and quadrant numbers Numbering convention of the quadrant number is different btw N and S. 2 St.3 St.2 St.1 RPC prototype St.3 St.2 St Collision point North arm (2) South arm (1)
MuTr gaps, planes 3 station 1 muon plane 1 plane 2 Gap 1Gap 2Gap 3 plane 1 plane 2 plane 1 plane 2
MuTr cathode strips View from IR Count from left to right (North arm) Count from right to left (South arm) (North arm) (South arm)
MuTr FEE chassis 5 From Nakagawa-san’s slide
MuTr FEE 6 Connector number Backplane channel Master Slave
MuTRG-ADTX chassis Slot 1 Slot 2 IN OUT IN OUT IN OUT IN OUT ADTX Connector number ch=1-16 ch=17-32 ch=33-48ch=
FEE-ADTX cable 8
CAMCAM COMCOM Flat cable Ch.1Ch.16 COM CAB Ch.2 Ch.3... FCI Connector shield Pseudo-chamber to ADTX cable pin arrangement Blue : signal White: GND
CAMCAM COMCOM FCI Connector shield FEE-ADTX cable pin arrangement Blue : GND White: Signal
FEE-ADTX (North Station 1) Gap number is indicated as color of the box for each connector. Strip region is indicated as color of the connector number. 11
FEE-ADTX (North Station 2) 12
FEE-ADTX (North Station 3) 13 Stereo wires were mistakenly selected in above table This slide is going to be updated.
FEE-ADTX (South Station 1) 14
FEE-ADTX (South Station 2) 15
FEE-ADTX (South Station 3) 16 Stereo wires were mistakenly selected in above table This slide is going to be updated.
Number of ADTX boards StationChassis/octBoard/octChassis/stationBoard/station North North North North_total South South South South_total Spare1156 Ground Total
MRG-VME slot Rack power controller MuTRG-VME(1) (south arm) Coolig fan MuTRG-VME(2) (south arm) Coolig fan Optical patch Rack power controller MuTRG-VME(3) (north arm) Coolig fan MuTRG-VME(4) (north arm) Coolig fan Optical patch
MuTRG-MRG 19 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 OUT
MuTRG-DCMIF 20 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN-GTM OUT
MuTRG-LL1 21 Tile 1 Tile 2 Tile 3 Tile 4 To be confirmed with ISU group
DCM
What’s next Make connector map (FEE-ADTX) for all octants – A correction is neccesary for MuTr map for station 3 where stereo wires were picked. Create a strip-based map – strip-to-ADTXch relation Put into postgreSQL database 23