FP420/AFP Fast Timing Stage I: LHC luminosity 2 x10 33  t < 20 ps (<2 year ) Stage II: 10 34  t < 10 ps (<4 years) Compare z-vertex position measured.

Slides:



Advertisements
Similar presentations
T958! Fermilab Test beam experiment to study fast timing counters for FP420 MOU between UTA, Alberta, Louvain, Fermilab (Brandt spokesman) Data taking.
Advertisements

AFP QUARTIC Fast Timing System James L Pinfold University of Alberta.
QUARTZTOFMike Albrow CMS-FP420 April 28 th 2008 QUARTZTOF An isochronous & achromatic Cerenkov Counter Making Cerenkov light parallel  point focusing.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Photon Counting Sensors for Future Missions
1 QUARTIC, A TOF for ATLAS/CMS Forward Protons You didn’t know that ATLAS+CMS had forward protons? FP420 = Forward Protons 420m downstream of CMS & ATLAS.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Fermilab / U. Chicago / Argonne Collaborative Initiative on Ultra Fast Timing Detectors With: (ANL) Karen Byrum, Gary Drake, Bob Wagner (UC) Henry Frisch,
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
1 QUARTIC: UTA Update Andrew Brandt, Chance Harenza, Joaquin Noyola, Pedro Duarte Preliminary UTA drawing of Mike Albrow’s concept for a fast time resolution.
Forward TOF Prototyping Ryan Mitchell GlueX Collaboration Meeting November 2005.
Groups Involved University of Alberta, University of Texas at Arlington, University College London. Prague, Saclay, Stoneybrook, Giessen, Manchester,
LHC Fast Timing Detector R&D Use arrival time difference between protons to measure z- vertex compared with the central tracking primary vertex Purpose:
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
Fast Timing Workshop Krakow, Nov 29 - Dec 1 st 2010 Part 2b.
TOF for ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely.
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
Blair Ratcliff2 nd Workshop on SuperB, Frascati, March Status Update: the Focusing DIRC Prototype at SLAC Blair Ratcliff Blair Ratcliff Representing:
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
ATLAS Forward Proton Electronics Andrew Brandt, University of Texas at Arlington 1 AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream.
1 QUARTIC Update Andrew Brandt (UT-Arlington), Mike Albrow (FNAL), Jim Pinfold (Alberta) Preliminary UTA drawing of Mike Albrow’s concept for a fast time.
THE FORWARD PROTON DETECTOR AT DZERO Gilvan Alves Lafex/CBPF 1) MOTIVATION 2) DETECTOR OPTIONS 3) FPD R&D 4) OUTLOOK Lishep 98 Lafex/CBPF Feb 17, 1998.
1 ALICE T0 detector W.H.Trzaska (on behalf of T0 Group) LHCC Comprehensive Review, March 2003.
FP420/AFP Timing Two types of Cerenkov detector are employed: QUARTIC – two QUARTIC detectors each with 4 rows of 8 fused silica bar allowing up to a 4-fold.
The primary goal has been to have the AFP timing system fully defined for the AFP Technical Proposal by December The end result should be a system.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Andrew BrandtSept 13 th 2005FP420/Cerenkov Intro 1 Location of LHC in France and Switzerland, with lake Geneva and the Alps in the background The ATLAS.
Mike AlbrowSept 14 th 2006Time-of-Flight with GASTOFs im Test Beam 1 Fast Timing Counters for FP420/CMS and Test Beam Particle ID Mike Albrow, September.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
Fast Timing Mtg April 15 th 2009 Mike Albrow Fast Timing studies at Fermilab : Test beam plans notes from meeting April 15 th 2009 MTest May Wed 27 th.
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
ALICE Fast Interaction Trigger detector for the future
Updates at Nagoya univ. K.Inami (Nagoya) - Photon detector R&D - Lifetime improvements - Simulation design study.
BURLE update Peter Križan Friday meeting, Mar 24, 2006.
Barrel PID upgrade K. Inami (Nagoya) Ljubljana, Hawaii, Cincinnati and PID group - R&D status - Structure design - Prototype study - Beam test - Photon.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
1992PH.D. UCLA/CERN (UA8 Experiment discovered hard diffraction) Post-doc and Wilson Fellow at Fermilab -Discovered hard color singlet exchange.
Barrel PID summary K.Inami (Nagoya) Summary of R&D at Hawaii, Cincinnati, Ljubljana and Nagoya.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
October 2002Sienna, JL. Faure, DAPNIA/SPP In 8th Topical Seminar on Innovative Particle and Radiation Detectors Jean-louis Faure CEA-DAPNIA-SPP Progress.
ARGONNE NATIONAL LAB G. Drake Electronics for Next-Generation Telescopes Oct. 21, 2005 p. 1.
Quartic tests at Fermilab test beam June rd 2015 One “prototype” module made. #1 ? To CERN mid July for August test beam.
Pileup Background Rejection Ex, Two protons from one interaction and two b-jets from another Fast Timing Detectors for FP420 z=c(TR-TL)/2  z (mm) =0.21.
Mike AlbrowFP420 – May Timing and Pile-up Considerations 1 Pile-up in trigger and pile-up off-line (HLT) very different issues. Here I consider.
AFP Fast Timing System Andrew Brandt, University of Texas at Arlington in collaboration with Alberta, Giessen, Stony Brook, and FNAL, Louvain, LLNL (CMS)
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
10 picoseconds original design goal (light travels 3mm in 10 psec!) gives large factor of background rejection; Phase I: lum up to several  t
Mike Albrow, FermilabHPS Comments, Manchester 20l0 Some random HPS comments Mike Albrow HPS is accepted in CMS as an R&D project : Physics case is accepted.
Time resolution for the full detector system: 1. Intrinsec detector time resolution 2. Jitter in PMT's 3. Electronics (AMP/CFD/TDC) 4. Reference Timing.
Mike AlbrowHPS – Nov 25thQUARTICs : Tests and Plans 1 May-June Fermilab beam tests The next QUARTICs Test plans … unfortunately delayed SiPMs …. Wavelet.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely measure.
Andrew Brandt, University of Texas at Arlington
HPS: R&D issues Krzysztof Piotrzkowski (UCLouvain/CERN)
Present Read Out Chain for the PANDA Barrel DIRC
Test Beam Studies for FP420 Fast Timing
Photon Detector for AFP
FP420 TOF- Past and Future TOF in ATLAS and CMS proposals The problem
Andrew Brandt (UT-Arlington), Mike Albrow (FNAL),
Directional Optical Module Integration
Latest Results from T979: PSec Time-of-flight
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Performance test of a RICH with time-of-flight information
Presentation transcript:

FP420/AFP Fast Timing Stage I: LHC luminosity 2 x10 33  t < 20 ps (<2 year ) Stage II:  t < 10 ps (<4 years) Compare z-vertex position measured with silicon tracking (  z=50  m) with vertex measured from time difference of protons (  z=2.1mm for  t=10 psec). Gives background rejection of Pileup Background Rejection for Diffractive Higgs (pp  pHp) Ex: Two protons from one interaction and two b-jets from another WHO? UT-Arlington (Brandt), Alberta (Pinfold), Fermilab (Albrow), Louvain (Piotrzkowski) +UC-London, Prague, Saclay, Stoneybrook, Giessen, BNL, Kansas… WHY? How? How Fast? 1Andrew Brandt, UT Arlington, SLAC Meeting5/20/2009

Fast Timing Is Hard! 3 mm =10 ps Rate and lifetime issues Background in detector and MCP Multiple proton timing Rad Hardness of detector, phototube and electronics, where to put electronics in tunnel ISSUES Time resolution for the full detector system: 1. Intrinsec detector time resolution 2. Jitter in MCP-PMT's or other photosensor 3. Electronics (AMP/CFD/TDC) 4. Reference Timing 2Andrew Brandt, UT Arlington, SLAC Meeting5/20/2009

Micro-channel Plate Photomultiplier Tube (MCP-PMT) Faceplate Photocathode Dual MCP Anode Gain ~ 10 6 Photoelectron  V ~ 200V  V ~ 2000V photon A photograph of an MCP showing an array of 12µm pores (holes) 35/20/2009

Fast Timing Detector: GASTOF (Louvain) Gas Cerenkov detector has low index of refraction, which limits total light, but full Cerenkov cone is captured. Simulations show yield of about 10 pe’s accepted within few ps! Have obtained 13 ps in TB (from fits to data). 4 Hamamatsu R3809U-50 6  m pore tube with Mini-circuits ZX-60 amplifier

4x8 array of 6 mm 2 fused silica bars UTA, Alberta, FNAL Only need 40 ps measurement if you can do it 16 times (2 detectors with 8 bars each)! Has advantage of x- segmentation for multi-proton timing (can offset two detectors to improve this further) proton photons 5Andrew Brandt, UT Arlington, SLAC Meeting5/20/2009 Fast Timing Detector : QUARTIC

Dt QUARTIC Timing 2008 CERN TB 56.6/1.4=40 ps/bar including CFD! Time difference between two 9 cm quartz bars after Louvain constant fraction discrimination is 56 ps, implies a single bar resolution of 40 ps CERN TB June /20/20096Andrew Brandt, UT Arlington, SLAC Meeting

6 mm Events Strip # Efficiency (a) (b) (c) Detector Efficiency Using Tracking All tracks (Bonn Silicon Telescope) Tracks with a Quartz bar on Use tracking (b)/(a) to determine that QUARTIC bar efficiency is high and uniform Shape due to veto counter with 15mm diameter hole 75/20/2009 Used scintillator trigger to synchronize silicon tracking data sample and oscilloscope data sample Andrew Brandt, UT Arlington, SLAC Meeting Fraction of events with good track and GASTOF on as a function of track position 90 to 99%, loss at edge understood from simulation, can be improved with mirroring of inside of GASTOF

Gastof Cosmic Ray Results 5/20/2009Andrew Brandt, UT Arlington, SLAC Meeting8 Obtained 13 ps resolution in test beam, even better in recent cosmic data run using Photek PMT210 3  m pore (<100 ps rise time!)

When the current demanded of the tube is too high the tube does not give as big an output signal, we call this saturation. Using 1 MHz/15 MHz and a gain of 10 5 (!) and 10 pe’s expected for our detector, we require 0.16  A/2.4  A (Anode current) in a.36 cm 2 pixel Cathode Current = proton frequency x number of photo-electrons generated by each proton x electron charge Anode Current = Cathode Current x gain In order to keep the Anode current at tolerable levels, lower gain is preferable as well as less photoelectrons (but precise timing needs as many pe’s as possible). In addition smaller pores improve timing and give more pores/area reducing the current in any one pore. Rate and Current Limits The LHC is a high rate accelerator and we need to establish if the MCP- PMT’s are capable of coping with the large expected rates: from 1 MHz in a 6mm x 6mm pixel at 2x10 33 luminosity to up to 15 MHz at The limiting quantity is not actually the rate, but the current in the tube: 9 Andrew Brandt, UT Arlington, SLAC Meeting 5/20/2009

Lifetime Issues Lifetime issues believed to be due to photocathode damage from +ions: Q/year = I*10 7 sec/year Assuming Gain=10 5 : Q in Phase I =1.6 to 4.8 C/year (in a 0.36 cm 2 pixel!) Q in Phase II 5x worse (up to 24 C/year or 72 C/ cm 2 /yr) Andrew Brandt, UT Arlington, SLAC Meeting 105/20/2009 Study issues with laser and pursuing solutions with Photonis, Photek, and Hamamatsu

Laser Gang LeCroy Wavemaster 6 GHz Oscilloscope Laser Box Hamamatsu PLP-10 Laser Power Supply Andrew Brandt, UT Arlington, SLAC Meeting 115/20/2009 ¾ of laser gang: Ryan Hall, Larry Lim, Mason MacPhail (Ian Howley not shown)

10  m Laser Setup with Reference Tube (3/17/09) Reference Tube (~6 ps) Andrew Brandt, UT Arlington, SLAC Meeting5/20/200912

Andrew Brandt, UT Arlington, SLAC Meeting Timing vs Gain for 10  m Tube Measured with respect to 25 um reference tube (6 ps) using CFD’s and x100 mini-circuits amps; with 10 pe’s can operate at ~5E4 Gain 135/20/2009

10 pe, 5E4 Gain Andrew Brandt, UT Arlington, SLAC Meeting Current for 10  m Tube 2x10 33 at 420m at 220m Photonis has successfully tested tube with 10x the rate capability! Timing only 10% worse but start to lose efficiency 5/20/200914

Improving Lifetime First step is to perform a lifetime measurement in laser lab, in similar environment as tube usage Photonis has new electron scrubbing machines: expect x5 to x10 lifetime improvement. Ion barrier certainly would help (at cost of x2 in collection efficiency)—used routinely in night vision Gen 3 tubes, and may be a solution on its own, or when coupled with better scrubbing. Would like to test this with Photonis tube. Pursuing small business proposal with Arradiance, which has new coatings that have shown promise in extending lifetime. If development promising would like to test in Photonis/Photek tubes. Other ideas more problematic (require more development), using lower gain on first MCP, Z stack, etc. Andrew Brandt, UT Arlington, SLAC Meeting155/20/2009

Fast Timing Summary Have tested detectors and electronics chain capable of 10 ps timing R&D still in progress to optimize all components Prototype system test beam including readout planned for this fall PMT lifetime is an ongoing issue, but pursuing options with vendors that seem likely to provide solutions on 3 year timescale (prior to max luminosity) 5/20/2009Andrew Brandt, UT Arlington, SLAC Meeting16

Backup Slides 5/20/2009Andrew Brandt, UT Arlington, SLAC Meeting17

Components of Fast Timing System For GASTOF replace CFD/TDC with single photon counter QUARTIC: Photonis planacon 10  m pore 8x8 or equivalent GASTOF: Hamamatsu 6  m pore single channel or equivalent Photek Mini-circuits ZX60 4 GHZ or equivalent Louvain Custom CFD (LCFD) HPTDC board (Alberta) Reference Timing Opto- modules/ ROD HV/LV UTA/Alberta for QUARTIC, PMT, Amp; barter with Louvain for GASTOF? (PMT sold separately!) Manchester/UCL Andrew Brandt, UT Arlington, SLAC Meeting 185/20/2009

LCFD Louvain (Luc Bonnet engineer) developed LCFD (Louvain Constant Fraction Discriminator) mini-module approach tuned LCFD mini-module to Burle and Hamamatsu rise times; 12 channel NIM unit Remote control for threshold 5/20/200919Andrew Brandt, UT Arlington, SLAC Meeting

Alberta HPTDC board 12ps resolution with pulser; Successfully tested last week with laser/10  m tube/ZX60 amp/LCFD/ scope 5/20/200920Andrew Brandt, UT Arlington, SLAC Meeting

S. White (BNL) has specified system still in conceptual design phase (presented at Oct. 17 fast timing meeting) Optical CFD dominates performance (< 5 ps) Provides average time as well for central event comparison 215/20/2009 Andrew Brandt, UT Arlington, SLAC Meeting