GERDA – a Search for Neutrinoless Double Beta Decay MPI für Physik, München Neutrinoless double beta decay and the GERDA experimentThe detector array and.

Slides:



Advertisements
Similar presentations
COBRA A new Approach to -Decay UK HEP Forum, Abingdon, May 11 th, 2003 Daniel Muenstermann University of Dortmund COBRA.
Advertisements

Key features: special electric field configuration usage of mirror pulses induced on contacts which do not collect charge Surface events and i nactive.
Activity for the Gerda-specific part Description of the Gerda setup including shielding (water tank, Cu tank, liquid Nitrogen), crystals array and kapton.
INTERNATIONAL PHD PROJECTS IN APPLIED NUCLEAR PHYSICS AND INNOVATIVE TECHNOLOGIES This project is supported by the Foundation for Polish Science – MPD.
Analysis and Results 3.Gamma-ray Spectra of 134 Cs The background subtracted spectra of 605 keV and 796 keV in multiple hit events, and their coincidence.
Pulse Shape Analysis with Segmented Germanium Detector Xiang Liu, Max-Planck-Institut für Physik 1.Motivation 2.Pulse properties 3.Analysis procedure 4.Some.
September 14, 2007Hardy Simgen, TAUP 2007 / Sendai1 Status of the GERDA experiment Hardy Simgen Max-Planck-Institut für Kernphysik Heidelberg on behalf.
M. Di Marco, P. Peiffer, S. Schönert
Results from M. Di Marco, P. Peiffer, S. Schönert Thanks to Davide Franco and Marik Barnabe Heider Gerda collaboration meeting, Tübingen 9th-11th.
WP2 Background simulations Outline Execution plan for the third year Progress of the work Activities and news.
GERDA: GERmanium Detector Array
Daniel Lenz, University of Wisconsin, Madison 11/05/ APS DNP Cryogenic search for neutrinoless double beta decay Daniel Lenz on behalf of the CUORE.
No s is good s Sheffield Physoc 21/04/2005 Jeanne Wilson A historical introduction to neutrinoless double beta decay.
The COBRA Double Beta Decay Search Experiment
COBRA Double Beta Decay Experiment D.Y. Stewart, Dr. Y.A. Ramachers, Prof. P.F.Harrison Experimental Particle Physics Group University of Warwick What.
30 Ge & Si Crystals Arranged in verticals stacks of 6 called “towers” Shielding composed of lead, poly, and a muon veto not described. 7.6 cm diameter.
Abdel Bachri, Southern Arkansas University In collaboration with Perry Grant, Martin Hawron, Clayton Martin, and Azriel Goldschmidt physica scripta, 2014.
Background Subtraction in Next Generation 0  Experiments Double-Beta Decay Challenges in 0  Decay Detection Small 0νββ decay half-life leads to low.
GERmanium Detector Array – a Search for Neutrinoless Double Beta Decay X. Liu - MPI für Physik, München Symposium – symmetries and phases in the universe,
Activity report of TG10 L. Pandola (LNGS) for the TG10 group Gerda Collaboration Meeting, February 3-5, 2005 (simulations and background studies)
CRESST Cryogenic Rare Event Search with Superconducting Thermometers Max-Planck-Institut für Physik University of Oxford Technische Universität München.
Temperature Dependence of the Crystal Properties of 18-fold Segmented HPGe Detector Allen Caldwell, Daniel Lenz, Jing Liu, Xiang Liu, Bela Majorovits,
Status of COBRA 6 th SNOLAB Workshop, Picture courtesy
Task Group 2 Iris Abt, Michael Altmann, Kevin Kroeninger, Bela Majorovits, Franz Stelzer, Xiang Liu 1.Detector Development 2.Suspension & Cabling 3.MC.
THE CUORE EXPERIMENT: A SEARCH FOR NEUTRINOLESS DOUBLE BETA DECAY Marco Andrea Carrettoni on behalf of the CUORE collaboration 2 nd International Conference.
Sensitivity to half life of 0νββ decay (left) and to effective Majorana neutrino mass (right) of an experiment as a function of exposure for different.
INTERNATIONAL PHD PROJECTS IN APPLIED NUCLEAR PHYSICS AND INNOVATIVE TECHNOLOGIES This project is supported by the Foundation for Polish Science – MPD.
Planned Transregional Collaborative Research Center TR27: Neutrinos and Beyond Project A4: Development of segmented germanium detectors for the investigation.
M. Wojcik Instytute of Physics, Jagiellonian University
1 IDM2004 Edinburgh, 9 september 2004 Helenia Menghetti Bologna University and INFN Study of the muon-induced neutron background with the LVD detector.
The CUORE experiment Thomas Bloxham Lawrence Berkeley National Lab PHENO 2011 May 9th 2011.
Monte Carlo Studies on Possible Calibration Sources Kevin Kröninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005.
M. Wójcik for the GERDA Collaboration Institute of Physics, Jagellonian University Epiphany 2006, Kraków, Poland, 6-7 January 2006.
Nuclear Track Emulsion Workshop Romania Nuclear emulsion with molybdenum filling for 2  -decay observation V.D.Ashitkov, A.S.Barabash, V.J.Bradnova,
Béla Majorovits for the GERDA collaboration ICHEP 2012, Melbourne, Australia, July Béla Majorovits for the GERDA collaboration Status and plans.
TG10 status report L. Pandola INFN, Gran Sasso National Laboratories for the TG10 Task Group Gerda Collaboration Meeting, Tuebingen November 9th – 11th,
What is MaGe? MJ outputGERDA output MaGe is a Monte Carlo simulation package dedicated to experiments searching for 0 2  decay in 76 Ge. Created by the.
Half Day IoP Meeting: Neutrinoless Double Beta Decay, University College London, Great Britain The GERDA Experiment at Gran Sasso Grzegorz Zuzel.
M. Wójcik Instytut Fizyki, Uniwersytet Jagielloński Instytut Fizyki Doświadczalnej, Uniwersytet Warszawski Warszawa, 10 Marca 2006.
The GERDA experiment L. Pandola INFN, Gran Sasso National Laboratory for the GERDA Collaboration WIN2009, Perugia, September 17 th 2009.
MaGe framework for Monte Carlo simulations MaGe is a Geant4-based Monte Carlo simulation package dedicated to experiments searching for 0 2  decay of.
MaGe: a Monte Carlo framework for the GERDA and Majorana experiments Luciano Pandola INFN, Laboratori Nazionali del Gran Sasso for the MaGe development.
Position sensitive CZT detectors for the COBRA neutrinoless double beta decay project Brian Fulton University of York Neutrinoless double beta decay The.
Cracow Epiphany Conference on Physics in Underground Laboratories and its Connection with LHC Cracow, Poland The GERDA Experiment at Gran.
Experiment [1] M. Di Marco, P. Peiffer, S. Schonert, LArGe: Background suppression using liquid argon scintillation for 0νββ - decay search with enriched.
BACKGROUND REJECTION AND SENSITIVITY FOR NEW GENERATION Ge DETECTORS EXPERIMENTS. Héctor Gómez Maluenda University of Zaragoza (SPAIN)
Activities on double beta decay search experiments in Korea 1.Yangyang Underground laboratory 2.Double beta decay search with HPGe & CsI(Tl) 3.Metal Loaded.
Background Subtraction in Next Generation 0  Experiments Double-Beta Decay Challenges in 0  Decay Detection Benjamin Spaun Whitworth College Advisors:
1 Performance and Physics with the CsI(Tl) Array at the Kuo-Sheng Reactor Neutrino Laboratory  Physics with CsI(Tl) detector  Period -2 configuration.
A screening facility for next generation low-background experiments Tom Shutt Case Western Reserve University.
The COBRA Experiment Jeanne Wilson University of Sussex, UK On behalf of the COBRA Collaboration TAUP 2007, Sendai, Japan.
M.Altmann, GERDA Status Report SNOLAB Workshop IV, Investigating Neutrinoless Double Beta Decay Status of the GERDA Experiment Michael Altmann.
PMN07 Blaubeuren Segmented germanium detectors in 0νββ-decay experiments Kevin Kröninger (Max-Planck-Institut für Physik, München)
SrCl 2 crystal for EC/  + search Presented by J.H. So (KNU)
Phase I: Use available 76 Ge diodes from Heidelberg- Moscow and IGEX experiments (~18 kg). Scrutinize with high siginificance current evidence. Phase II:
Sep. 22, 2011 Seoul National University Jae Keum Lee KIMS Background 1 China-Korea Workshop 2011 September 22-23, 2011.
November 19, 2007Hardy Simgen, IDEA-Meeting Paris Status of the GERDA experiment Hardy Simgen Max-Planck-Institut für Kernphysik Heidelberg on behalf.
MPI für Physik, Fachbeirat, Béla Majorovits The GERDA experiment Béla Majorovits.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
JINR group V. Brudanin, V. Egorov, K. Gusev, A. Klimenko, O. Kochetov, I. Nemchenok, V. Sandukovsky, A. Smolnikov, M.Shirchenko, D. Zinatulina Project.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
Towards pulse shape calculation and analysis for the GERDA experiment Kevin Kröninger, MPI für Physik International School of Nuclear Physics, Erice 2005.
The COBRA Experiment: Future Prospects
Overview of GERDA simulation activities with MaGe
Prompt Gamma Activation Analysis on 76Ge
GERDA Collaboration Meeting,
Deep learning possibilities for GERDA
Pre-Test-stands at MPI Munich
GERDA Test Stands for Segmented Germanium Detectors
Presentation transcript:

GERDA – a Search for Neutrinoless Double Beta Decay MPI für Physik, München Neutrinoless double beta decay and the GERDA experimentThe detector array and phase II detectors Detector test stands Suppression of background from radioactive decays Materials and radio-purity Background summary and sensitivity Neutrinoless double beta decay (0νββ) is an extremely rare second order weak process which is predicted to occur, if the neutrino is a Majorana particle. The half-life of the process is a function of the neutrino masses, their mixing angles and CP-phases. Today‘s best limit on the half-life of the 0νββ-process of 76 Ge is measured by the Heidelberg-Moscow collabo- ration with T 1/2 > 1.9·10 25 years (90% C.L). Signal Background (Co-60) Schematic view of an array of segmented detectors. The location of radioactive decays are indicated by yellow dots, the segments with energy deposist are shown in green. For the signal process (left) only one segment is hit, whereas for background processes (here: the decay of Co-60) (right) the photons scatter multiple times (red lines) and deposit energy in more than one segment. Energy spectra for Co-60 for different anti-coincidence requirements: no anti- coincidence (black), between crystals (green) and between segments (red). For events with only one segment hit the reduction is larger by an order of magnitude with respect to those with only one crystal hit. PartBackground index [10 -4 counts/kg/keV/y] Detector5 Holder (copper)4 Holder (Teflon)8 Cabling6 Electronics3 Infrastructure4 Muon, neutron & co.2 GERDA32 Overview of the background contributions to the spectrum expected in the GERDA experiment using the Monte Carlo package MaGe and the expected level of radioimpurities from the material screening. For photons in the energy region around 2 MeV Compton scattering is the dominant process of energy loss. The range of photons is on the order of centimeters and therefore of the size of a crystal segment. The signal process has two electrons in the final state. Their energy is deposited on a scale small compared to the size of a crystal segment. By requiring an anti- coincidence between segments, photon-accompanied background can be suppressed by a factor of depending on the decaying isotope. The main sources of background are radioactive isotopes with Q-values larger than that of 76 Ge, Q ββ = MeV. Depending on their position, the energy measured in the detectors is due to α-particles, electrons and/or photons. If only part of the energy is deposited in the detector and the size of the energy deposition is around the Q-value of 76 Ge the observed „event“ can be mis- interpreted as 0νββ. Background events with photons in the final state can be suppressed by anti-coincidence requirements bet- ween segments. Schematic diagram of neutrinoless double beta decay. The nucleus changes its charge by two units. If the neutrino is a Majorana particle, the two emitted neutrinos can annihilate. Only two electrons remain in the final state. size of 8 cm height and 4 (0.5) cm outer (inner) radius. Each crystal will have a mass of approximately 2.1 kg. The crystals will be segmented and each segment is read out separately. A 6-fold segmentation in the azimuthal angle φ and a 3-fold segmentation in the height z is planned. The suspension system is designed such that a minimum of material is used. For the phase II detectors the holder is made of copper and Teflon with a total weight of 31 g. A prototype detector is currently being tested. The energy resolution is measured as 2 keV at 1.3 MeV. Left: Prototype detector with the current cabling scheme. The holder structure is made of copper and Teflon with a total weight of 31 g. The detector mass is 2.1 kg. Right: Detector array as simulated. The detectors are placed hexagonally in strings of 3 detectors each. The read-out electronics will be located above the top crystals. Spectrum of a 232 Th source taken with a Phase II prototype detector. The core resolution is measured as 2 keV, the segment resolution is 2-3 keV (at 1.3 MeV). The materials which surround the germanium detectors have to be specially selected with respect to their radio-purity so as to minimize possible background contributions from radioactive decays. The radio-purity of the materials is measured down to the μBq/kg level. Examples for the radiopurity of materials used in the vicinity of the germanium crystals. The values are used for a Monte Carlo simulation which is performed in order to estimate the background contribution with the GERDA setup (see bottom right box). The activities are measured except for the cables which are estimated. For further details on material screening see the poster of Dušan Budjáš. The sensitivity to neutrinoless double beta decay of 76 Ge strongly depends on the background index of the experiment. A Monte Carlo study, based on the radio-impurities of the used materials and the muon flux, was performed in order to estimate the total background. With the materials assumed the background index is calculated to be 3.2·10 -3 counts/(kg keV y) and dominated by radioactive decays from isotopes in the holder structure. Improvements on the material radiopurities and additional analysis techniques using pulse shape information will help to further decrease the background index. Sensitivity of the GERDA experiment using a Bayesian analysis technique. The lower limit for an exposure of 100 kg years and the ensvisioned background index of counts/(kg keV y) is T 1/2 >1.35·10 26 years. Using a Bayesian analysis on Monte Carlo data the 90% probability lower limit which can be set on the half-life, in case no observation is made, is calculated. For the envisioned background index of counts/(kg keV y) and an exposure of 100 kg years the lower limit on the half-life is T 1/2 >1.35·10 26 years which corres- ponds to a limit on the effective neutrino mass of m ee <200 meV/c 2. The detectors will be placed in a hexagonal pattern in strings of three detectors each. The read-out elec- tronics will be located above the top crystals. The current design of the germanium detectors for the phase II forsees a true-coaxial geometry with a crystal The GERmanium Detector Array, GERDA, is a new experiment that will search for neutrinoless double beta decay of the germanium isotope 76 Ge. Its main design feature is to submerge and operate high purity germanium detectors, enriched in 76 Ge to a level of 86%, directly in a cryogenic liquid (nitrogen or argon). The latter serves as coolant and shield from external radiation simultaneously. The cryostat is placed inside a buffer of ultra-pure water which serves as additional shielding and will be instrumented as Cherencov detector in order to veto cosmic muons. With this setup a background index of counts/(kg·keV·y) is expected. The GERDA experiment will be installed in the Hall A of the Gran Sasso National Laboratory, LNGS, in Italy. A phased approach is chosen for GERDA. In phase I germanium detec- tors from previous experiments will be installed. The detectors for phase II are currently under design. A total mass of 35 kg of germanium for phase II is expected. The LNGS is located at the Gran Sasso mountain region about 150 km from Rome. The laboratory is covered by an average of 1,400 m of rock which significantly reduces the flux of cosmic muons. PartIsotopeActivity Crystal (germanium)Ge-68O(3 μBq/kg) Co-60O(0.2 μBq/kg) Holder (copper)Co-60< 10 μBq/kg Ra-226< 16 μBq/kg Th-228< 19 μBq/kg Holder (Teflon)Ra-226< 160 μBq/kg Th-228< 160 μBq/kg CablingRa-2262 mBq/kg Th-2282 mBq/kg Test stands for segmented germanium detectors are under construction at the MPI. Their main purpose is to verify the functioning of bare crystals in liquid nitrogen and the understanding of detector responses. On the pictures: current test stands for germanium detectors constructed at the MPI. Left: The germanium detector can be scanned in 3D with different sources. After putting the detector inside the source will rotate around the crystal. The drifting charge carriers in the detector can be studied in detail. Right: Two segmented crystals are submerged directly in liquid argon (liquid nitrogen). The resolution and leakage current are monitored continuously. This test stand is used to verify that segmented germanium detectors can operate stably in cryoliquid. The GERmanium Detector Array Germanium detectors Water / Myon-Veto (Č) Clean room / lock Liquid nitrogen / argon Cryo-tank / vacuum