W. Chang, MBA, A. B. Landgraf, BS, S. Kecskemeti, MS, K. Johnson, PhD, Y. Wu, PhD, J. Velikina, PhD, O. Wieben, PhD, C. Mistretta, PhD, and P. Turski,

Slides:



Advertisements
Similar presentations
Usefulness of velocity profiles based on 3D cine PC MR used as boundary conditions for computational fluid dynamics of an intracranial aneurysm : investigation.
Advertisements

MRAClub 2014 Accurate Estimation of the volume flow rate in the cerebral artery using 3D cine phase-contrast MRI (4D-Flow) P. 1 Tokyo Institute of TechnologyR.
Real-Time MRI – Outline Biomed NMR JF11/59 Technical Considerations - Data Acquisition - Image Reconstruction Preliminary Applications - Joint Movements,
Abstract: Characterization of coronary artery’s motion is important to obtain optimal coronary CT images. Previous studies have mainly performed 2D analysis.
Magnetic resonance is an imaging modality that does not involve patient irradiation or significant side effects, while maintaining a high spatial resolution.
Dept. of Radiology, Mie University School of Medicine, Mie, Japan
Markus Strohmeier Sparse MRI: The Application of
Compressed Sensing for Chemical Shift-Based Water-Fat Separation Doneva M., Bornert P., Eggers H., Mertins A., Pauly J., and Lustig M., Magnetic Resonance.
Numerical modelling of affected zone for cerebral aneurysm A.A.Cherevko, A.P.Chupakhin, A.L.Krivoshapkin, A.K.Khe, K.Y.Orlov, P.A.Seleznev Lavrentyev Institute.
Dr. Daniel Riahi, Dr. Ranadhir Roy, Samuel Cavazos University of Texas-Pan American 34 th Annual Texas Differential Equations Conference Modeling and computation.
بسم الله الرحمن الرحيم.
THE CORRELATIONS OF 3D PSEUDO-CONTINUOUS ARTERIAL SPIN LABELING AND DYNAMIC SUSCEPTIBILITY CONTRAST PERFUSION MRI IN BRAIN TUMORS Delgerdalai Khashbat,
MR ANGIOGRAPHY USING SPIN LABELING – DETERMINATION OF FEEDING AND DRAINING VESSELS OF ARTERIOVENOUS MALFORMATIONS C. Warmuth, C. Zimmer, A. Förschler Charité,
How I do CMR Myocardial Perfusion imaging SCMR Website 2006 Christopher Klassen MD, PHD University of Florida Health Science Center Dr. Norbert Wilke This.
Contrast Agent Transport Simulation using 4D PC-MRI Derived Flow Fields Ali Bakhshinejad, Roshan M. D'Souza, Loic Boussel, Vitaliy L. Rayz
Unsteady hemodynamic simulation of cerebral aneurysms А.А.Cherevko, А.P.Chupakhin, А.А.Yanchenko ( IGiL SB RAS, NSU)
HighlY Constrained Back PRojection (HYPR) Thank you to Oliver Wieben!!
MRI-Based Assessment of Neovasculariation in Carotid Plaque – A Novel Risk Marker for Plaque Rupture Lawrence L. Wald, Ph.D. MGH Martinos Center for Biomedical.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
EP Discordance of CTA and Digital Subtraction Angiography in Diagnosing Vasospasm Following Subarachnoid Hemorrhage ASNR 53 rd Annual Meeting – April.
Compressed Sensing 4D Flow Reconstruction using Divergence-free Wavelet Transform Frank Ong 1, Martin Uecker 1, Umar Tariq 2, Albert Hsiao 2, Marcus Alley.
Departments of Radiology and Medical Physics University of Wisconsin-Madison Vessel Branch Segmentation of Phase Contrast Vastly undersampled PRojection.
NEW SEQUENCES LAVA Liver Acquisition with Volume Acceleration.
Flowing Matter – COST Action MP1305, , Sofia NUMERICAL ANALYSIS OF THE STENOSIS EFFECTS ON THE BLOOD FLOW IN THE COMMON CAROTID ARTERY BIFURCATION.
Michael Ficorelli.  To describe clinical indications for C.T.A. examinations in the circulatory system. To understand and recognize anatomy and landmarks.
CT ANGIOGRAPHY Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture CT IMAGE OF THE BLOOD VESSEL OPACIFIED.
Diagnostic Imaging on Intracranial Atherosclerotic Stenosis Eduardo Freire Mello Department of Interventional Neuroradiology Hospital Espanhol, Salvador.
Kamran M 1, Deuerling-Zheng 2, Mueller-Allissat B 2, Grunwald IQ 1, Byrne JV 1 1. Oxford Neurovascular and Neuroradiology Research Unit, University of.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
BOLD functional MRI Magnetic properties of oxyhemoglobin and deoxyhemoglobin L. Pauling and C. Coryell, PNAS USA 22: (1936) BOLD effects in vivo.
He-Kwon Song, PhD Associate Professor & Co-investigator in the CMROI, Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia,
August Medical student course Joseph Philip MD
ME 7980 Cardiovascular Biofluid Mechanics
Advanced flow MRI: emerging techniques and applications
Diagnostic Medical Sonography Program
Warren Chang, MD/MBA, Pablo Villablanca, MD, and Aichi Chien, PhD
Comparison of MRA Techniques for Calcification Detection
Sunday Case of the Day Physics
Monday Case of the Day Physics
Sunday Case of the Day Physics (Case 1: MR)
M. Fathi, A. Bakhshinejad, A. Baghaie, D. Saloner, R. Sacho,
Case Study: Effect of resolution enhancement on the accuracy of 4D flow MRI data Ali Bakhshinejad April 21, 2018.
Applications of Dual-Energy Computed Tomography for the Evaluation of Head and Neck Squamous Cell Carcinoma  Reza Forghani, MD, PhD, Hillary R. Kelly,
Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root.
Santanu Chakraborty, MD, FRCR, Reem A. Adas, MD 
Time-resolved magnetic resonance angiography and flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla for blood flow and wall shear stress.
Axial source images of left severe ICA stenosis; small residual lumen with vessel wall plaque and thick calcification on the sides. Axial source images.
Axial CT scans of the brain and neck performed with contrast medium.
Volume 105, Issue 2, Pages (July 2013)
VW-MR imaging to differentiate among causes of intracranial arterial stenosis when angiography findings are inconclusive. VW-MR imaging to differentiate.
3T-versus-7T DTI with 36 diffusion-encoding directions at b = 3000 s/mm2 and 2.0 × 2.0 × 2.0 mm isotropic voxel resolution. 3T-versus-7T DTI with 36 diffusion-encoding.
Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects 
Dual-Energy Computed Tomography
A, Left internal carotid artery (ICA) angiogram showing a left middle cerebral artery (MCA) bifurcation aneurysm and an additional distal MCA aneurysm.B.
Technical implementation of VW-MR imaging.
Common VW-MR imaging pitfalls.
Patient 2: CNS vasculitis in a 37-year-old woman with systemic lupus erythematosus. Patient 2: CNS vasculitis in a 37-year-old woman with systemic lupus.
A, Axial source image from a contrast-enhanced MRA unambiguously demonstrates a tiny (
Patient 3: Hemorrhage in CNS vasculitis.
Presidential address: A brief history of arterial blood flow—from Harvey and Newton to computational analysis  Joseph P. Archie, PhD, MD  Journal of Vascular.
Comparison of contrast-enhanced MR angiography of spinal cord vessels with use of gadopentetate dimeglumine (Magnevist; A, B, and C) and the blood pool.
Patient 6: 24-year-old woman with primary angiitis of the CNS
TOF-MRA (first column), FSBB (second column), and an intraoperative photomicrograph (third column) of 4 different patients with various degrees of atherosclerosis.
Case 6, a 73-year-old woman with SAH
Fig. 4. A 74-year-old female with right hemiplegia and aphasia, 2 hours ago. (a) DWI shows hyperintense lesion in the entire left cerebral hemisphere.
Case 2: Agenesis of the left ICA
 (A) Axial FLAIR MRI reveals multiple areas of high signal intensity (arrows) in leptomeninges.  (A) Axial FLAIR MRI reveals multiple areas of high signal.
Patient with a 6-mm aneurysm of the AcomA that was treated with GDCs
Case 25. Case 25. This patient presented with a decreased level of consciousness and was treated with intra-arterial nimodipine for symptomatic cerebral.
Presentation transcript:

W. Chang, MBA, A. B. Landgraf, BS, S. Kecskemeti, MS, K. Johnson, PhD, Y. Wu, PhD, J. Velikina, PhD, O. Wieben, PhD, C. Mistretta, PhD, and P. Turski, MD Hemodynamics at the Carotid Terminus and Surrounding Segments Assessed Using Highly Accelerated High-Resolution Phase Contrast MR Velocimetry and Automated Spline Interpolation W. Chang, MBA, A. Frydrychowicz, MD, B. Landgraf, BS, S. Kecskemeti, MS, K. Johnson, PhD, Y. Wu, PhD, J. Velikina, PhD, O. Wieben, PhD, C. Mistretta, PhD, and P. Turski, MD

3D-Radial vs Cartesian Acquisitions The Nyquist conditions regulate how many projections are needed to avoid aliasing in MRA and other modalities. With a Cartesian readout, violating the Nyquist conditions may result in streak artifacts, compromising image quality. In radial undersampling, violating the Nyquist conditions will result in artifacts localized to the periphery away from vessels, and are better tolerated, resembling normal noise. 1,2 This effect is enhanced when the region of interest is sparse, allowing increased radial undersampling without excessive aliasing, allowing higher resolution and lower scan times. 1) Peters et al, MRM, ) Mistretta, JMRI, 2009 Schematic of 3D PC-VIPR acquisition.

PC-VIPR, a fast 3D-radial PC-MRA technique PC-VIPR is a phase-contrast 3D radial technique with high spatial resolution (0.68x0.68x0.68mm) capable of acquiring whole-brain angiograms with velocity information with scan times of 5 minutes. 3,4 3) Wu et al, AJNR, )Nett, et al, JCMR, 2009

Wall Shear Stress (WSS) is defined as the derivative of velocity with respect to the distance from the wall, multiplied by the viscosity. It represents the drag that parallel flowing fluid imposes on the wall. Phase Contrast techniques such as PC-VIPR have velocity information that can be used to estimate WSS values. High spatial resolution is necessary to accurately acquire WSS at the boundary zone of the vessel. WSS can’t be acquired in-vivo therefore measurements represent an estimate of the true WSS. However, they can differentiate normal and pathologic flow conditions. Wall Shear Stress Relationship between velocity and WSS.

Abnormal wall shear stress (WSS) is prevalent at areas prone to atherosclerosis and promotes an atherogenic phenotype. 5 Non-laminar flow, leading to abnormal WSS, changes endothelial gene expression and affects the boundary zone, leading to plaque formation and progression. 6 Both high and low WSS has also been associated with the formation and progression of saccular cerebral aneurysms. 7 Relationship between Wall Shear Stress and Atherosclerosis Atherosclerotic stenosis in the left MCA showing low WSS distal to the plaque. 5) Malek et al, JAMA,1998 6) Cunningham and Gottlieb, Lab Inv, ) Hoi et al, JNS, 2004

Materials and Methods 10 healthy volunteers (6 female, 4 male) were scanned using a GE Health Discovery T MR Scanner (GE Healthcare, Waukesha, WI) with an 8 channel head coil (Excite HD, GE Healthcare, Waukesha, WI) using PC-VIPR. 8 A low resolution scan was followed by contrast injection and PC-VIPR acquisition to acquire a time series of high-res images. PC VIPR Scan Parameters were: TR/TE: 8.2/2.8 α = 20 o Bandwidth = 83.3 KHz Scan time = 300 sec Velocity encoding = 80 cm/s Field of View = 220x220x220 mm 3 Resolution = 0.68 x 0.68 x 0.68 mm 3 8) Johnson et al, MRM, 2008

Acquisition of WSS with PC-VIPR Images were reconstructed using HYPR-LR reconstruction 9 and imported into Ensight where cutplanes were made axial to vessels of interest (MCA, ICA, ACA). Cutplane being made in the left MCA using Ensight. 9) Mistretta et al, MRM, 2006

Calculation of WSS using spline interpolation The cutplanes were then imported into a MATLAB runtime environment developed in conjunction with the University of Freiburg, Germany. 10 Points were selected around the border of the vessel and the program automatically calculated WSS using B-spline interpolation and Green’s theorem. Total processing time per patient was less than 30 minutes. PC-VIPR images allow whole-brain WSS mapping. 10) Stalder, et al, 2008, MRM

Results These values were consistent with values found in the literature for WSS acquired using PC-MRA. 11,12 11) Oyre, et al, JACC, ) Chang et al, AJNR 2011 VesselWall Shear Stress Standard Deviation Middle Cerebral Arteries0.95 Pa0.32 Pa Anterior Cerebral Arteries0.89 Pa0.59 Pa Terminal Internal Carotid Arteries 1.17 Pa0.60 Pa

Complex flow in normal volunteers 13) Chang et al, NRJ, 2011

Complex flow in normal volunteers (cont)

Clinical Applications High resolution PC-MRA imaging can be used to evaluate stenoses and aneurysms. This patient has bilateral vertebral artery stenoses and basilar and vertebral artery aneurysms that are visualized using high-resolution PC- MRA. 14 Increased velocity is seen in the stenoses and a helical flow pattern can be seen in the aneurysms. 14) Chang et al, RSNA, 2010

Clinical Applications (cont) Comparison of WSS map of the aneurysm with streamline visualization.

Clinical Applications (cont) 14) Chang et al, RSNA, 2010

Clinical Applications (cont)

13) Chang et al, NRJ, 2011 Clinical Applications (cont)

PC VIPR is a radial undersampled PC-MRA technique capable of acquiring whole-brain images with velocity information. Using high- resolution velocity information from PC-VIPR, spline interpolation can be used to localize the boundary zone and calculate axial WSS. WSS has prognostic value in determining areas vulnerable to atherosclerotic plaque deposition and aneurysm development. We are currently using a combination of velocity, its derivatives such as streamlines and WSS, and morphology to evaluate patients with stenoses, aneurysms, arteriovenous malformations, and vasospasm. This workup can identify and characterize pathologic flow conditions. Radial PC-MRA may offer clinicians a non-invasive imaging solution that does not expose patients to invasive techniques or radiation. Conclusion/Future Work