MCP Testing Using Square Conductive Pads as Readout Anode Sagar Setru 1/19/2014.

Slides:



Advertisements
Similar presentations
1 Space Sciences Lab, UC Berkeley, CA, USA High performance microchannel plate detectors for UV/visible Astronomy Dr. O.H.W. Siegmund Space Sciences Laboratory,
Advertisements

Speed-I View from Material Side Qing Peng, Anil U. Mane, Jeffrey W. Elam Energy Systems Division Argonne National Laboratory Limitations on Fast Timing.
Update of EXT Stripline BPM Electronics with LCLS-style Digital BPM Processors Glen White, with slides by Steve Smith 15 December 2009 ATF2.
The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
SPIE San Diego - J. Vallerga John Vallerga, Jason McPhate, Anton Tremsin and Oswald Siegmund Space Sciences Laboratory, University of California,
Optical image tube with Medipix readout
Microchannel Plates signals, Picosecond timing, Design’s minimum performance.
SPIE Instr. for Astronomy, Marseille, John Vallerga, Optically sensitive MCP image tube with a Medipix2 ASIC readout John Vallerga,
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Existing fabrication facilities for PC's for imaging MCP detectors Dr. O.H.W. Siegmund Experimental Astrophysics Group Space Sciences Laboratory University.
SPIE IR and Photoelect. Imagers and Detector Devices J. McPhate Jason McPhate, John Vallerga, Anton Tremsin and Oswald Siegmund Space Sciences.
Mid-IR photon counting array using HgCdTe APDs and the Medipix2 ROIC
Photon Counting Sensors for Future Missions
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
9th IWoRiD: Erlangen,July 2007, John Vallerga High resolution UV, Alpha and Neutron Imaging with the Timepix CMOS readout J. Vallerga, J. McPhate, A. Tremsin.
Space Astronomy: The UV window to the Universe, El Escorial, May 2007, John Vallerga The current and future capabilities of MCP based UV detectors J. Vallerga,
Medipix2 meeting Dec Medipix Activity at Berkeley John Vallerga, Jason McPhate, Anton Tremsin and Bettina Mikulec.
SPIE Instrumentation for Astronomy AO - June22, 2004 John Vallerga, Jason McPhate, Anton Tremsin and Oswald Siegmund Space Sciences Laboratory, University.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
WSO Detector Workshop Leicester University, Dec. 2007, John Vallerga UV detectors in Space John Vallerga Space Sciences Laboratory University of California,
2nd Zwicky Informal Workshop - Berkeley 2005 May 26, 2005John Vallerga John Vallerga, Barry Welsh, Anton Tremsin, Jason McPhate and Oswald Siegmund Experimental.
Ultra-sensitive HALO monitor N. Vinogradov, A. Dychkant, P. Piot.
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
ALD 20µm Microchannel Plates
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Measurement Results Detector concept works! Flood fields show MCP fixed pattern noise that divides out Spatial resolution consistent with theory (Nyqvist.
Cartigny, 2 July First Results Using the Medipix2 Photon Counting ASIC as Readout for a Micro-Channel-Plate Detector - Proposal for a New Wavefront.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
WSO/UV-LSS Detector with large dimension MCP Baosheng Zhao* National Astronomical Observatories of CAS *
LLNL AO talk - Aug. 17, 2004 John Vallerga, Jason McPhate, Anton Tremsin and Oswald Siegmund Space Sciences Laboratory, University of California, Berkeley.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Chevron / Zigzag Pad Designs for Gas Trackers
New Test Facilities at Argonne LAPPD Collaboration meeting June Matt Wetstein, Bernhard Adams, Matthieu Chollet.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Development of a high-speed single photon pixellated detector for visible wavelengths Introduction A photon incident on the photocathode produces a photoelectron.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
TPC PAD Optimization Yukihiro Kato (Kinki Univ.) 1.Motivation 2.Simple Monte Carlo simulation 3.PAD response 4.PAD response for two tracks 5.Summary &
Sofia_SIRAD_LAZIO. Sofia_SIRAD The first variant of apparatus Sofia_SIRAD for on board of ISS investigations mechanical structure was design; The first.
COS Training Series II. Optimizing Observations --- David Sahnow February mm.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Investigation of effects associated with electrical charging of fused silica test mass V. Mitrofanov, L. Prokhorov, K. Tokmakov Moscow State University.
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
33mm MCP Testing at UC Berkeley
Overview of MCP requirements: resistive layer and SEE A. S. Tremsin, O. H. W. Siegmund Space Sciences Laboratory University of California at Berkeley Berkeley,
Update on Physical Parameters that influence Timing Jean-Francois Genat LPNHE Paris LAPPD Electronics & Integration Review July 9th 2012, Chicago.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
Proportional chambers with cathode readout in high particle flux environment Michał Dziewiecki.
Chem. 133 – 2/11 Lecture. Announcements Lab today –Will cover 4 (of 8) set 2 labs (remainder covered on Tuesday) –Period 1 will extend one day Website/Homework.
N A S A G O D D A R D S P A C E F L I G H T C E N T E R I n s t r u m e n t S y n t h e s i s a n d A n a l y s i s L a b o r a t o r y APS Formation Sensor.
Jean-François Genat Fast Timing Workshop June 8-10th 2015 FZU Prague Timing Methods with Fast Integrated Technologies 1.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
A. SarratILC TPC meeting, DESY, 15/02/06 Simulation Of a TPC For T2K Near Detector Using Geant 4 Antony Sarrat CEA Saclay, Dapnia.
Gain and Time Resolution Simulations in Saturated MCP Pores Valentin Ivanov, Zeke Insepov, Sergey Antipov 1 First Author Institution, 2 Second Author Institution,
- Herve Grabas - Ecole Superieure d’Electicite 1 Internship presentation - University of Chicago – 3 sept
Page Detector and Electronics R&D for picosecond resolution, single photon detection and imaging J.S. MilnesPhotek Ltd T.M. ConneelyUniversity.
1Jean-Francois Genat on behalf of the LAPPD collaboration (
Neutron Imaging and Tomography with MCPs
M. Manghisoni, L. Ratti Università degli Studi di Pavia INFN Pavia
Surface Concept Position Sensitive MCP Detectors Novel Solutions A
Entrance Muon Counter (EMC)
L. Ratti, M. Manghisoni Università degli Studi di Pavia INFN Pavia
Pre-installation Tests of the LHCb Muon Chambers
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
The MPPC Study for the GLD Calorimeter Readout
Readout Electronics for Pixel Sensors
Presentation transcript:

MCP Testing Using Square Conductive Pads as Readout Anode Sagar Setru 1/19/2014

Motivation Purpose: measure MCP characteristics – Uniformity – Gain – Stability – MCP Charge depletion/rate dependence (10 3 Hz) – Position resolution (10 -6 m) – Dark current Needs to be in vacuum (10 -6 Torr) Complementary to APS/UChicago apparatus – Near ALD lab, fast, stand-alone, limited

Apparatus layout No cathode Incoming photon generates electron on MCP surface Resulting charge cloud lands on anode with padded conductors Apparatus layout based on SSL Cross Strip/Cross Delay Line 1 and APS test apparatus 2 MCP Signal ~2.5mm Padded Anode Analog to Digital Converter MCPs Bias Voltage Readout channels photon Laser 1 O.H.W. Siegmund, A. Tremsin, J.V. Vallerga and J. Hull. Microchannel Plate Imaging Photon Counters for Ultraviolet through NIR Detection with High Time Resolution. Proc SPIE May 12; 8033: Bernhard Adams, Matthieu Chollet, Andrey Elagin, Eric Oberla, Alexander Vostrikov, Matthew Wetstein, Razib Obaid and Preston Webster.. A test-facility for large-area microchannel plate detector assemblies using a pulsed sub-picosecond laser. Rev. Sci. Instrum. 84, (2013).

Readout overview Measure, digitize gain from each pad Find the center (X,Y) of charge cloud from charge distribution – Use modified center of mass algorithm (‘center of charge’) Readout pads each have their own channel Mounted on inside of CF flange Readout pads Conflat Flange Analog-to-Digital Converter X axis Y axis Readout pads Charge Cloud Computer Signals from pads

What is the trade-off between good spatial resolution and practicality?

6σ ≈ 3.5 mm Approximate signal from MCP as 2D Gaussian cloud of charge 1 Dimensions of cloud fixed – σ = mm – 6*σ ≈ 3.5 mm – 6σ gives approx. diameter of cloud A ≈ 10 6 electrons, RMS – Represents gain (x 0, y 0 ) is center 1 A. S. Tremsin, J. V. Vallerga, O. H. W. Siegmund, J. S. Hull, Proc. SPIE, vol. 5164, Centroiding algorithms and spatial resolution of photon counting detectors with cross strip anodes, UV/EUV and Visible Space Instrumentation for Astronomy II, San Diego (2003) Modelling MCP Output A = 10 6 e - x0x0 y0y0

Monte Carlo simulations to determine resolution vs. pad size 1.Place Gaussian charge cloud on array of square pads – Placed at random position – Noise per pad ≈ 500 electrons, RMS 2.Read out the pads 3.Calculate position of center of charge cloud 4.Compare calculated position of center with actual, Monte Carlo position of center 5.Repeat – Many times per pad size – Several pad sizes Signal 1 Signal 2 Signal 3 Signal 4

Example calculation of reading out pads in simulation Integrate 2D Gaussian function Bounds of integration are positions of pad border Example: a 4 mm by 4 mm pad: -4 4 (0,0) 4 X Y σ = mm A = 10 6 electrons, gain of signal from MCP Cloud charge is centered at (1,1) Charge cloud (1,1)

Center of charge algorithm

Initial results Why does resolution get worse as pad size decreases?!

Answer: noise from pads 1 A. S. Tremsin, J. V. Vallerga, O. H. W. Siegmund, J. S. Hull, Proc. SPIE, vol. 5164, Centroiding algorithms and spatial resolution of photon counting detectors with cross strip anodes, UV/EUV and Visible Space Instrumentation for Astronomy II, San Diego (2003)

Solution: center of charge algorithm with a threshold 1 A. S. Tremsin, J. V. Vallerga, O. H. W. Siegmund, J. S. Hull, Proc. SPIE, vol. 5164, Centroiding algorithms and spatial resolution of photon counting detectors with cross strip anodes, UV/EUV and Visible Space Instrumentation for Astronomy II, San Diego (2003) Threshold

Resolution now improves as pads become smaller! But why does resolution start going up for the smallest pads?

Answer: different pad sizes have different ideal threshold So must fix pad size and compare different thresholds Looked at 0.25, 0.5, 1, 1.25, 1.5 mm pads Thresholds used (as percent of total charge) – 0.001, 0.002, 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100

Example results: resolution vs. threshold (fixed pad size) 1.25 mm pads 0.5 mm pads

Another study: resolution vs. noise Noise increases position resolution at the submicron level Very low noise (< 100 e -, RMS) —nearing single micron/sub micron resolution

Conclusions Standard center of charge centroiding fails with small pads because of noise – Must use a threshold to remove far away signals Different pad sizes have different ideal thresholds Less noise is better for resolution, even with threshold centroiding

Conclusions

To do 1. Tank design – MCP holder, spacing 2. Anode – Mounting, design, electronics 3. Laser spot size 4. Laser scanner 5. Frequency of laser 6. Determine electronic noise

Appendix: Investigating the sudden jump in resolution vs. threshold Occurs at a different threshold for different padsizes 1.25 mm pads 0.5 mm pads

Appendix: Investigating the sudden jump in resolution vs. threshold Before jump/at low thresholds: – Identical to standard centroiding w/out threshold – Makes sense (letting nearly all charge through) 1.5 mm 0.5 mm

Appendix: Investigating the sudden jump in resolution vs. threshold Very high thresholds – Undefined resolution – Makes sense (eventually letting no data through) 1.5 mm 0.5 mm No resolution