Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam Working Group University of Glasgow University of Connecticut Catholic University of America
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Photon Beam: coherent bremsstrahlung Criteria Criteria high energyE g = 8-10 GeV polarizationP O, P | 0.5 high fluxN g = 10 8 s -1 energy resolutions E = 10 MeV low backgrounds Design options Design options A.laser backscatter B.synchrotron backscatter C.bremsstrahlung D.coherent bremsstrahlung energy polarization flux resolution ( ) ( ) ( ) ( ) background ABC ( ) with tagging D
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Photon Beam: energy spectrum effects of collimation at 80 m distance from radiator incoherent (black) and coherent (red) kinematics
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Photon Beam: coherent gain factor gain increases with electron beam energygain vanishes at the end-point
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Photon Beam: polarization circular polarization transfer from electron beam reaches 100% at end-point linear polarization determined by crystal orientation vanishes at end-point 5
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Photon Beam: polarization linear polarization polarization spectrumpeak polarization vs. electron energy 6
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Photon Beam: collimation a < 20 mr s 0 < 1/3 c d > 70 m polarization grows with improved collimation
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Electron Beam: properties energy12 GeV r.m.s. energy spread7 MeV transverse x emittance10 mm µr transverse y emittance2.5 mm µr electron polarizationavailable minimum current100 pA maximum current5 µA x spot size at radiator1.6 mm r.m.s. y spot size at radiator0.6 mm r.m.s. x spot size at collimator0.5 mm r.m.s. y spot size at collimator0.5 mm r.m.s. position stability±200 µm
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Diamond crystal: properties limits on thickness from multiple-scatteringrocking curve from X-ray scattering
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Diamond crystal: gonimeter mount natural width of diamond is ~5 mm
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Tagging spectrometer Requirements Requirements spectrum coverage 25% -- 85% in 0.5% steps 70% -- 75% in 0.1% steps energy resolution 10 MeV r.m.s. rate capability up to 400 MHz per GeV
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Tagging spectrometer: two dipole design (selected spectrometer characteristics table here)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Tagging spectrometer: optics design (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Tagger focal plane: fixed array (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Tagger focal plane: microscope (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Beam line: active collimator (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Beam line: polarimetry (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Beam line: shielding (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Beam line: simulation (mm)
Richard Jones, GlueX Detector Review, Newport News, October 20-22, Beam line: rates and background (mm)