Page 1 MCQUAY DIGITAL SCROLL SYSTEM Installation.

Slides:



Advertisements
Similar presentations
KV / kV2 Meter RSX Option Board (RS-485 mode) Connections Notes: 1) TP1-1 = Twisted Pair set #1, wire #1 2) TP1-2 = Twisted Pair set #1, wire #2 3) TP2-1.
Advertisements

Inspection & Preventive maintenance of breakers
Basic Jens Neigaard.
Daikin Altherma™ Troubling Shooting
HEAT PUMPS.
Page 1 MDS Installation. Page 2 Contents  Introduction  Outdoor Unit Installation  Indoor Unit Installation  Refrigerant Pipe Work  Gas Charge 
Installation. Indoor Unit Installation Typical Installation.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
 A 'heat exchanger' may be defined as an equipment which transfers the energy from a hot fluid to a cold fluid. Here, the process of heating or cooling.
Reference Document1 Noise Cancellation Techniques This presentation is a property of Kaihatsu Techno Centre Pvt. Ltd. This is intended for the restricted.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
Installation. Indoor Unit Installation Typical Installation.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Chapter 26 Communication Systems. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Identify common.
Equipment Installation, piping & wiring Variable Water Flow System.
1 CCTV SYSTEMS PAN, TILT AND ZOOM CAMERAS. 2 CCTV SYSTEMS A PTZ camera is a pan, tilt, and zoom camera that is different from a fixed dome camera in that.
The printed circuit board (PCB) design
MDS Smart Commander.
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
LBT Q Engineering Review PSPI: PEPSI installation preparation, includes all of the pier modifications.
LBT Q Engineering Review PSPI: PEPSI installation preparation, includes all of the pier modifications.
RESIDENTIAL AIR HANDLERS
On/Off Temp Holiday Select Fan Air clean Operation Auto SwingRoom Temp Week Select SET/CLR Hour MIN Timer Program Set Fan Speed Jet Cool Cancel RESET E_Heater.
Installation. Indoor Unit Installation Typical Installation.
T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R SineWave - Installation rules.
1 Cables A large portion of electrical signals are transmitted through solid electrical solid electrical conductors. A wire is a single conductor. A cable.
MDS COMMISSIONING.
Service Section Technical Training. Good Air Conditioning Installation Practices.
MDS Monitoring Software. Page 2 Contents  Introduction  User Interface  Service Personnel Interface  System Requirement  Demonstration.
1 HVACR316 - Piping Safety Solder and Braze Joints Safety Solder and Braze Joints.
Principles of correct VRV Installation A. Refrigerant pipe work
Heat Exchange Ventilation Heat Exchange Ventilation.
TECHNICAL TRAINING 2007 CONTROLLER PROGRAM UPGRADE.
ROOFING MATERIALS, INSULATION, AND HOUSING SYSTEMS.
1 HVACR316 - Piping Safety Solder and Braze Joints Safety Solder and Braze Joints.
Installation of heating cables, a light and an outlet with a thermostat and two pole circuit breaker.
Penn ESE370 Fall DeHon 1 ESE370: Circuit-Level Modeling, Design, and Optimization for Digital Systems Day 36: December 6, 2010 Transmission Lines.
Page 1 MCQUAY DIGITAL SCROLL SYSTEM Unit & Piping Selection.
MCQUAY DIGITAL SCROLL SYSTEM
9/18/2003Safety Review Electronics Electronics design LV, HV power supply Fusing Heat.
Network Cabling Presentation by: Dani Johnson, Dominik Pecararo, Tommy Yowell.
Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox LEAD SPLICE SPECIFICATION  BY: ROY HANNAFORD.
Page 1 AMDS Selection. Page 2 Contents Introduction Selection Consideration Selection Process Software Demonstration.
Basic Slide Show Under Tile Spooled Heating Installation Guide.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
Problem Solving using Error Code Saijo Denki Inverter R-410A
Suggestion for installation Demolish and destroy the old air condition, then send them to owner building Install a new one by last main.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
Air condition installation
Air-cooled Modular Chiller Installation
Air source heat pump Understand the fundamental principles and
CMV-NET Chigo VRF Network Centralized Control System
VRF Trouble Shooting 采用midea通用PPT模版, 参考《公司简介》PPT.
CHIGO VRF System Commissioning.
Site Controller Unit and Trunk Interface Unit
AHU connection kit.
Cassette Type Room Air conditioner 14th August 2016, Kuantan, Pahang.
Heat-Timer Control Options
Electrical Junction Boxes in UAE | SPPE
MDS Selection.
TECHNICAL TRAINING 2007.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
MDS Smart Commander.
GENERALPIPINGREQUIREMENTS:. Designing and erecting an efficient piping system requires certain aspects/ requirements which could be found in our PME handbook…
Error codes for split systems
Bunker Wall Design Wall ESS
Liebert DSE High efficiency thermal management
Difference between Earthing & Grounding
Presentation transcript:

Page 1 MCQUAY DIGITAL SCROLL SYSTEM Installation

Page 2 INSTALLATION Bad Installation – System will not operate as per design Waste of Money Waste of Time Bad Image 3 Major Categories Unit Installation Piping Installation Wiring Installation

Page 3 INSTALLATION Unit Installation Indoor Unit Outdoor Unit Note: Installation of indoor unit is same as normal direct expansion unit.

Page 4 INSTALLATION Outdoor Unit Installation Sufficient area around the unit. No barrier for supply air and discharge air. Avoid discharge air return to the unit (Hot Air short- circuiting) Strong foundation for the unit

Page 5 INSTALLATION Handling Outdoor Unit Correct

Page 6 INSTALLATION Handling Outdoor Unit Wrong

Page 7 INSTALLATION CorrectWrong

Page 8 INSTALLATION

Page 9 INSTALLATION Outdoor Unit Spacing (Single Outdoor Unit) Wall / Barrier higher than unit Side View Wall / Barrier lower than unit

Page 10 INSTALLATION Outdoor Unit Spacing (Single Outdoor Unit) Top View (Barrier higher than unit)

Page 11 INSTALLATION Outdoor Unit Spacing (Single Outdoor Unit) Top View (Barrier lower than unit)

Page 12 INSTALLATION Outdoor Unit Spacing (More than 1 unit) Top View (Wall / Barrier restriction same as 1 outdoor unit)

Page 13 INSTALLATION Outdoor Unit Spacing (More than 1 unit) Top View (Wall / Barrier restriction same as 1 outdoor unit)

Page 14 INSTALLATION Outdoor Unit Spacing (More than 1 unit) Top View (Wall / Barrier restriction same as 1 outdoor unit)

Page 15 INSTALLATION Outdoor Unit Foundation Floor location strength Able to withstand the unit weight and vibration Layout for drainage, piping & cables Different level, avoid blocking. Important for MDS260~300B(BR). Oil balancing pipe must be lower than the connection joint Screw bolt required to further tighten the unit Avoid the unit from falling due to earthquake

Page 16 INSTALLATION Piping Installation Ensure piping is dry, clean and no air leakage

Page 17 INSTALLATION Piping Installation Refnet & distributor joints to be install horizontally

Page 18 INSTALLATION Piping Installation Refnet & distributor joints to be install horizontally

Page 19 INSTALLATION Piping Installation EXV box to be install vertically

Page 20 INSTALLATION Piping Installation Insulation Able to withstand the pipe heat Heatpump Unit – heat resistance polyethylene foamed ( > 120 Deg C) Cooling only - Polyethylene ( > 100 Deg C) Insulation method Thickness of insulation

Page 21 INSTALLATION Insulation Method Wrong Method Correct Method

Page 22 INSTALLATION Thickness of insulation Depends on pipe diameter Notes: Hot and wet environment, increase then thickness of the insulation Cooling with ambient less than 10 deg C, recommended to insulate the liquid pipe.

Page 23  Twisted Pair wired with shielding (20AWG)  Shield wire to be earth on 1 end of the network  Connected serially to the adjacent unit (Daisy Chain Connection)  Same polarity between units CONTROL Communication

Page 24 System Wiring CONTROL For the last indoor, Jumper JP-7 need to be shorted (Top left Corner of the indoor board) Communication

Page 25 System Wiring CONTROL A in = Terminal 30 B in = Terminal 31 A PC = Terminal 32 B PC = Terminal 33 Communication

Page 26 BABA Indoor PCB Outdoor PCB MDS080~240 CONTROL Communication

Page 27 System Wiring - MDS260~300B(BR) CONTROL For the last indoor, Jumper JP-7 need to be shorted (Top left Corner of the indoor board) Communication

Page 28 Indoor Units MDS260/280/300 MDS130/150BRSMDS120/150BRM + CONTROL Communication

Page 29 Gateway Computer Indoor units Outdoor units Centralize Control RS485 RS232 CONTROL 1. Review indoor unit status and error history 2. Monitor and control all indoor unit 3. Weekly timer and holiday timer setting Control & Monitoring Software

Page 30 Thank You