Cold BPM development in KEK H. Hayano, March 2011 Jung Keun Ahn (PNU), Sun young Ryu (PNU), Eun San Kim (KNU), Young Im Kim (KNU), Jin yeong Ryu (KNU),

Slides:



Advertisements
Similar presentations
Cavity BPM for Spectromety: progress and plans A. Lyapin.
Advertisements

Development of ML-BPM for STF cryomodule H. Hayano, KEK SunYoung Ryu, PNU.
Testing and Development of Feed-Forward System for ATF2 A. Kalinin Accelerator Science and Technology Centre, Daresbury Laboratory, UK Fifth ATF2 Project.
1 KEK Cavity BPM Hitoshi Hayano Development of Cavity BPM for Q-magnet attachment, Aiming; compact design, 0.2µm resolution, BPM center error (between.
Bob Lill Undulator Systems – Cavity BPM October 12, 2006 Undulator Cavity BPM Status.
PEDM Review 12/7/091 Beam Position Monitors William Morse.
Bob Lill Undulator Systems – BPM April 20, 2006 Undulator Cavity BPM Status and Plans.
Bob Lill Undulator Cavity BPM System April 16, 2007 Undulator Cavity BPM Status.
Progress towards nanometre-level beam stabilisation at ATF2 N. Blaskovic, D. R. Bett, P. N. Burrows, G. B. Christian, C. Perry John Adams Institute, University.
ATF2 Status and Plan K. Kubo ATF2, Final Focus Test for LC Achievement of 37 nm beam size (Goal 1) – Demonstration of a compact final focus.
IP-BPM NOV. BEAM TEST RESULTS Siwon Jang (KNU). 11cm Low-Q IP-BPM design  11cm Low-Q IP-BPM drawings of HFSS 100mm Sensor cavity Wave guide Antenna Designed.
High Resolution Cavity BPM for ILC final focal system (IP-BPM) ILC2007/LCWS 2007 BDS, 2007/6/1 The University of Tokyo, KEK, Tohoku Gakuin University,
Tesla Meeting Frascati 27/05/03 C. Magne Cold BPM for TTF2 Tesla prototype - low beam impedance - cooling to 2K without strain - Low beam coupling impedance:
BPMs and HOM-BPMs for the XFEL Linac N. Baboi for the BPM and the HOM teams (DESY, CEA-Saclay, SLAC, FNAL, Cockroft/Daresbury) XFEL Linac Review Meeting,
Bob Lill Undulator Systems – BPM January 31, 2006 Undulator Cavity BPM Design and Status.
Experience on design, prototyping and testing of cavity BPM for the European-XFEL > Motivation > Introduction > Principle of CBPMs > Mechanical properties.
Feedback On Nanosecond Timescales (FONT): Robert Apsimon, Philip Burrows, Neven Blaskovic, Douglas Bett, Glenn Christian, Michael Davis, Davide Gamba,
Status of the Fermilab Cold BPM R&D Manfred Wendt Fermilab 10/1/20091LCWA09 Main Linac WG.
Chris Adolphsen Main Linac Integration. CAVITY VESSEL T4CM QUAD/Correctors T4CM BPM QUADS LEADS 80K BLOCK 4K BLOCK Quadrupole Package.
1 C. Simon CLIC Instrumentation workshop BPM C. Simon on behalf of the Saclay’s group CLIC Instrumentation workshop 2 nd - 3 rd June.
The Cavity Beam Position Monitor (BPM) Massimo Dal Forno Paolo Craievich, Raffaele De Monte, Thomas Borden, Andrea Borga, Mauro Predonzani, Mario Ferianis,
Energy Spectrometer for the ILC Alexey Lyapin University College London.
IP-BPM status Siwon Jang KNU. Contents The electronics repair status –Repair work status –Electronics RF test (by using Oscilloscope) –Electronics shipment.
Development of a Low-latency, High-precision, Intra-train Beam Feedback System Based on Cavity Beam Position Monitors N. Blaskovic Kraljevic, D. R. Bett,
Status of the ILC Main Linac BPM R&D Thibaut Lefevre CERN Claire Simon CEA Sacley Sebastien Vilalte LAPP Manfred Wendt Fermilab 11/19/20081ILC08 Main Linac.
The beam-based alignment and feedback systems, essential operations of the future colliders, use high resolution Beam Position Monitors (BPM). In the framework.
1 FONT R&D status Philip Burrows Douglas Bett, Neven Blaskovic, Glenn Christian, Michael Davis, Young Im Kim, Colin Perry John Adams Institute Oxford University.
High resolution RF cavity BPM design for Linear Collider Andrei Lunin 8th DITANET Topical Workshop on Beam Position Monitors.
Production and Installation Policy of IP-BPM ATF2 Project Meeting, 2006/12/18 Y. Honda, Y. Inoue, T. Hino, T. Nakamura.
1 H. Hayano for the ATF collaboration Low Emittance Beam Generation in ATF H. Hayano for the ATF collaboration BPM electronics improvement emittance tuning.
High resolution cavity BPMs in the context of the European XFEL
Wake Fest 07 - ILC wakefield workshop at SLAC Dec , 2007 Shilun Pei with Chris Adolphsen, Zenghai Li, Karl L. Bane, et al. SLAC, Dec. 12, 2007 TTF.
Compton Experiment at ATF Compton Meeting at LAL Orsey 2-Dec-2008 Tsunehiko OMORI (KEK) with many thanks to Compton collaborators.
Status of the Cold BPM Developments at CEA Saclay and Fermilab L-Band Cavity BPM: Nathan Eddy, Andrei Lunin, Eric Pirtle, Gennady Romanov, Nikolay Solyak,
1 Feedback On Nanosecond Timescales (FONT): Philip Burrows Neven Blaskovic, Douglas Bett, Glenn Christian, Michael Davis, Young Im Kim, Colin Perry John.
Low-Q IP-BPM Schedule Siwon Jang KNU. IP-BPM Schedule IP BPM schedule –Reference cavity (middle of October) Frequency tuning parts –Electronics (middle.
IP BPM’s for ATF2 Vladimir Vogel KEK May30, 2005 Third Mini-Workshop on Nano Project at ATF.
Beam Test status and Plans of the ILC Main LINAC BPM
STF phase 2 plan H. Hayano, STF phase 2 Accelerator Layout cavities: 2 capture cavities with short ILC-cross-section cryomodule + 26 cavities.
1 Cold L-Band Cavity BPM: Design Status July 2006 Gennady Romanov Linda Valerio Manfred Wendt Fermilab July 21, 2006.
BPM for FF test (ATF2) Vladimir Vogel KEK 2nd Nano Workshop, KEK, December 12, 2004.
Fermilab BPM R&D Activities Nikolay Solyak, Manfred Wendt Fermilab Nicolas Chritin, Lars Soby CERN Nobuhiro Terunuma, Junji Urakawa KEK March 26-30, 20101LCWS10.
MLI Summary Chris Adolphsen SLAC. Summary of MLI Talks Quadrupoles (V. Kashikhin) –Expect test of a SLAC/CIEMAT and FNAL cos(2phi), ~ 60 T/m, SC Quads.
1 Feedback On Nanosecond Timescales (FONT): Philip Burrows Neven Blaskovic, Douglas Bett, Glenn Christian, Michael Davis, Young Im Kim, Colin Perry John.
Low-Q IP BPM Y. I. Kim *, A. Heo, E-S. Kim (KNU) S. T. Boogert (JAI) D. M. McCormick, J. May, J. Nelson, T. Smith, G. R. White (SLAC) Y. Honda, N. Terunuma,
Development of a High Resolution Cavity BPM for the CLIC Main Beam
IoP HEPP/APP annual meeting 2010 Feedback on Nanosecond Timescales: maintaining luminosity at future linear colliders Ben Constance John Adams Institute,
1 1 H. Hayano and ATF group ATF Status August/2004 H. Hayano and ATF group Multibunch emittance Instrumentation developments Plans for run Multibunch.
MLI Update Chris Adolphsen SLAC. CAVITY VESSEL T4CM QUAD T4CM BPM QUADS LEADS 80K BLOCK 4K BLOCK Quadrupole Package.
CLIC Beam instrumentation work shop, CERN, 2 nd & 3 rd of June 2009, Lars Søby BPM overview CLIC instrumentation work shop 2-3 June BPM overview.
1CEA/ Saclay/ SACM CARE/SRF/WP11 Development of a new Beam Position Monitor for FLASH, XFEL and ILC Cryomodules Claire Simon, Michel Luong, Stéphane Chel,
WFM electronics Alexandra Andersson. F. Peauger – CTF3 committee – 11/02/10  Wakefield Monitors implemented in two accelerating structures TD24 (tank.
CLIC Workshop 18 th -22 nd January 2016, CERN 1 Alfonso Benot Morell Manfred Wendt.
Fast Beam Collision Feedbacks for luminosity optimisation at next-generation lepton colliders Philip Burrows John Adams Institute Oxford University.
HOM-BPM study in STF for cavity miss-alignment detection
Status of BPMs and Electronics System at KNU.
Re-entrant BPM R&D for ILC Main Linac
CAVITY BPM FOR CALIFES Claire Simon, Michel Luong, D. Bogard, P
Wakefield & Cavity based Monitors: Fermilab BPM Development Plans
IPBPM test results at the LINAC end
KNU IP-BPM and Reference cavity
CLIC Workshop 2016: Main Beam Cavity BPM
ATF nanoBPM system - nanoGrid ATF2 Movers TTF HOM – dipole / monopole
    BEAM POSITION MONITORS USING A RE-ENTRANT CAVITY C. Simon1, S. Chel1, M. Luong1, P. Contrepois1, P. Girardot1, N. Baboi2 and N. Rouvière3.
Bunch Tiltmeter Steve Smith SLAC Snowmass July 16, 2001 Update date
Fabrication of KEK-ATF2 Q-BPM
Instability measurement plans at ATF
Undulator Cavity BPM Status
Breakout Session SC3 – Undulator
小型X線源の性能確認実験計画 高輝度・RF電子銃研究会 広島大学 高エネルギー加速器研究機構 浦川順治
Presentation transcript:

Cold BPM development in KEK H. Hayano, March 2011 Jung Keun Ahn (PNU), Sun young Ryu (PNU), Eun San Kim (KNU), Young Im Kim (KNU), Jin yeong Ryu (KNU), Hitoshi Hayano (KEK)

STF cold-BPM for phase-2 cryomodule 4-way cylindrical coupling wave-guideRe-entrant type cavity BPM 4-way cylindrical coupling wave-guide

re-entrant cavity + coupling waveguide structure Φ78mm 115mm Eigen-mode of re-entrant cavity: dipole mode Port1 to Port3 Frequency: GHz QL : 205 β : isolation to other port : -27dB (1)Modification from Saclay re-entrant BPM (2) common-mode rejection by coupling WG (3) More compact than cylindrical cavity BPM (4) HPR washable simple structure (5) ø78mm big beam pipe (6) < 1µm resolution for each bunch in the train (7) low-Q value for less interference between bunch Frequency selection : Avoid dark current freq., Avoid cavity HOM freq. Appropriate freq for re-entrant structure.

Prototype-BPM : building block type (non-vacuum tight) Material: SUS

Beam test set-up in ATF Linac Reference cavity Proto-type BPM installed in the vacuum chamber housing Vacuum chamber housing with tilt and yaw angle adjuster Signal cables

Upstream Strip-line BPM Downstream Strip-line BPM Beam test set-up using two strip-line BPM

dipole mode: 2.04GHz signal in 200ns full span signal is well damped after 300ns next bunch position Dipole signal from re-entrant BPM with Band-pass-filter 2.04 GHz signal with beam intensity 0.5x10 10 electrons/bunch

Antenna scan for electrical center confirmation X-scanY-scan -120µm +82µm

Estimated beam X position from strip-line BPM [µm] 2.04GHz detected signal [ADC count] Slope=5.33 ADC-count/µm σ = 1.96 count Pedestal noise Setup: Hybrid, BPF, RF Amplifier, diode, ADC 1.96/5.33=0.36µm resolution at 1x10 10 beam intensity Simple analog signal detection for resolution measurement

Summary of re-entrant BPM development (1) Re-entrant cavity BPM + cylindrical coupling wave-guide pickup was designed by HFSS. (2) Proto-type (building-block type) BPM was fabricated by stainless-steel. (3) Antenna scan was done to confirm small electrical center offset from mechanical center. (4) ATF beam test was done using simple electronics setup, and confirmed good position resolution less than 1µm and small common-mode mixture. (5) Phase detection relative to the reference cavity signal was also tried. The results are still under analysis. Future Plan (1) Vacuum tight proto-type is under design and start fabrication. (2) Cool-down test and beam test at ATF are planned. (3) Installation into STF phase-2 CM1 in fall 2012, is a primary target.