Automatic Control System V. Performance of steady-state.

Slides:



Advertisements
Similar presentations
Dynamic Behavior of Closed-Loop Control Systems
Advertisements

Closed-Loop Transfer Functions
Feedback loop (CV changes input) SP Controller Gc Plant Gp Sensor Gs E MV (Manipulated Variable CV Controlled Variable +-+- S.
Automation I. Introduction. transmitter actuator Structure of control system Process or plant Material flow sensorstransducers actuating units actuating.
CHE 185 – PROCESS CONTROL AND DYNAMICS
Lect.7 Steady State Error Basil Hamed
T S R Q R Q = (R(ST) | ) | = (R(SQ) | ) | T S R Q CEC 220 Revisited.
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
Chapter 7 System Compensation (Linear Control System Design)
Compensation Using the process field G PF (s) step response.
Chapter Summer 2. Comparator 3. Block Blocks in Series
Dynamic Behavior and Stability of Closed-Loop Control Systems
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Chapter 4: Feedback Control System Characteristics Objectives
Feedback Controllers Chapter 8.
Control System Instrumentation
Introduction to Process Control
Chapter 8. The PID Controller Copyright © Thomas Marlin 2013
Chapter 7 PID Control.
Introduction to Industrial Control Systems
Lecture 5: PID Control.
1. 2 LOOP DYNAMICS To keep track of deviations from the free-running frequency,
Ch. 6 Single Variable Control
Motion Control. Two-Link Planar Robot Determine Kp and Kv and Tv.
Automatic Control System
Cascade and Ratio Control
Control Engineering Application
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Control System Instrumentation
Introduction to Process Control
Feedback Controllers Chapter 7.
1 Chapter 11 Compensator Design When the full state is not available for feedback, we utilize an observer. The observer design process is described and.
Chapter 8 Feedback Controllers 1. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control.
Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Sensitivity.
Features of PID Controllers
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
Review. Feedback Terminology In Block diagrams, we use not the time domain variables, but their Laplace Transforms. Always denote Transforms by (s)!
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
Chapter 7 Steady State Error <<<4.1>>>
Óbudai Egyetem Dr. Neszveda József Open and Closed loop Control II. Block diagram model.
Lecture 5\6 Analysis in the time domain (I) —First-order system North China Electric Power University Sun Hairong.
C HAPTER 1 Introduction to control system. The basic ingredients of control system can be described by: Objectives of control or input. Control-system.
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control Ms Anis Atikah Ahmad
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
Automatic control systems V. Discrete control
SAL COLLEGE OF ENGINEERING
Control System Instrumentation
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control
Chapter 1: Overview of Control
Automatic control systems III
Automatic control systems I. Nonlinearities in Control System
Controllers and Positioners
Automatic control systems I
Introduction to control system
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 4: Feedback Control System Characteristics Objectives
Linear Control Systems
Basic Design of PID Controller
Control System Instrumentation
Automatic Control System
Process Control Engineering
Control System Instrumentation
Features of PID Controllers
Introduction to Process Control
Control Systems Prof Swanson MECH 3550.
Control System and Transfer Function
Control Systems Prof Swanson MECH 3550.
Presentation transcript:

Automatic Control System V. Performance of steady-state

plantcontroller Terms of feedback control reference input element reference signal comparing element or error detector error signal compensator or control task action signal feedback signal actuator transmitter manipulated variable disturbance variable controlled variable block model of the plant

Working points in steady-state U YMYM Y UMUM In steady-state the value of the action signal U, manipulated U M, and controlled Y variables, and the feedback signal Y M are constant. W Y UMUM U YMYM In steady-state the output of a loop’s element is the input of the next block. The steady-state characteristics of the elements must be fitted each other. The disturbance w variable’s deviation of the average value changes the plant’s steady-state characteristic curve. It’s important: A new steady-state can be achieved by the system. W0W0

Choosing steady-state characteristics of controller The steady-state characteristic of the plant, transmitter and the actuator is given by the technologies. We can choose only the steady-state characteristic of the controller. If higher action signal belongs to higher feedback signal then the characteristic is direct. If lower action signal belongs to higher feedback signal then the characteristic is reverse. The dynamic behavior of the controller eliminates the steady-state error.. Y UMUM U YMYM W0W0 In this case there isn’t a new steady-state value of system.

Choosing steady-state characteristics of controller A bad choice of controller steady-state characteristics also causes an unstable control loop. Y UMUM U YMYM Sometimes the technologies requirements need a reverse characteristics of the actuator. Sometimes the steady-state characteristics of technologies is concave and not convex. W0W0 In this case there is a new steady-state value of system.

Transfer functions of feedback loop G P (s)G R (s) G W (s) G A (s) G C (s) G T (s)

System type of feedback loop System type is the number of the pure integral lag in the loop. The possible values are 0, 1, 2. K 0 is the loop gain. Opened-loop transfer function, Bode form. G P (s)G R (s) G W (s) G A (s) G C (s) G T (s)

A ship wants to turn to the port. The continuous movement of the steering wheel turns the ship. The surface of the ship against the river backwash also continuously increase. How much is the deflection error if r(t)=0.2*t*1(t) is the changes of the reference signal and w(t)=0.1*t*1(t) is the changes of the disturbance variable. The domains are: Y = ± 80 [°], R = 4 – 20 [mA]. Example v

The steady-state error of closed loop control

The size of the error might be appropriate, but we do not know anything about the quality characteristics.

Setpoint tracking The setpoint tracking depends on: Order of the feedback system. The loop‘s gain (K 0 ). The form of the reference signal The setpoint tracking means that the controlled variable (y(s)) is able to follow the prescribed value by the changes of the reference signal (r(s)) after the transient has died. We assume that the disturbance variable (W 0 (s)) equals the designed value (w(s)=0). We can examine this with the error transfer function:

Setpoint tracking Standard signal Order of the feedback system t t t

Disturbance suppression The disturbance suppression depends on: Order of the feedback system. The loop‘s gain (K 0 ). The form of the reference signal. The attack point of the disturbance variable. The disturbance suppression means that the controlled variable (y(s)) is able to hold the prescribed value by the changes of the disturbance variable (w(s)) after the transient has died. We assume that the reference signal (R 0 (s)) equals the working point value (r(s)=0). We can examine this with the disturbance-error transfer function:

Disturbance suppression Standard signal Order of the feedback system t t Entering point of disturbance t