NI Big Physics Summit CERN

Slides:



Advertisements
Similar presentations
Uli Schäfer 1 Ethernet-driven control and data acquisition scheme for the Timepix-based TPC readout C. Kahra, U. Schäfer, M.Zamrowski Uni Mainz.
Advertisements

Digital RF Stabilization System Based on MicroTCA Technology - Libera LLRF Robert Černe May 2010, RT10, Lisboa
E-link IP for FE ASICs VFAT3/GdSP ASIC design meeting 19/07/2011.
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
Synchrotron applications of pixel and strip detectors at Diamond Light Source Julien Marchal, Nicola Tartoni, Colin Nave Diamond Light Source 03/09/2008.
Developing the Timepix Telescope Planning a Future Timepix Telescope Richard Plackett – VELO Testbeam Meeting CERN, 7th October 09.
20 Feb 2002Readout electronics1 Status of the readout design Paul Dauncey Imperial College Outline: Basic concept Features of proposal VFE interface issues.
6 June 2002UK/HCAL common issues1 Paul Dauncey Imperial College Outline: UK commitments Trigger issues DAQ issues Readout electronics issues Many more.
Silicon Photomultiplier Readout Electronics for the GlueX Tagger Microscope Hall D Electronics Meeting, Newport News, Oct , 2007 Richard Jones, Igor.
Mid-IR photon counting array using HgCdTe APDs and the Medipix2 ROIC
Detector Array Controller Based on First Light First Light PICNIC Array Mux PICNIC Array Mux Image of ESO Messenger Front Page M.Meyer June 05 NGC High.
Manfred Meyer & IDT & ODT 15 Okt Detectors for Astronomy 2009, ESO Garching, Okt Detector Data Acquisition Hardware Designs.
Agenda Adaptation of existing open-source control systems from compact accelerators to large scale facilities.
MEDIPIX3 TESTING STATUS R. Ballabriga and X. Llopart.
Institute of Experimental and Applied Physics Czech Technical University in Prague 11th December 2007 Michal Platkevič RUIN Rapid Universal INterface for.
A multi-chip board for X-ray imaging in build-up technology Alessandro Fornaini, NIKHEF, Amsterdam 4 th International Workshop on Radiation Imaging Detectors.
-1- Current Telescope Strengths High resolution (~2.5um) Adaptability Ease of use – Currently borrowed by SPS collimator group Weaknesses Small number.
AIDA annual meeting,Vienna, 26th March 2014Václav Vrba, Institute of Physics, Prague 1  design of sensors for production submission  design of the readout.
Cern.ch/knowledgetransfer. Knowledge Transfer | Accelerating Innovation HEPTech Workshop on Technology Licensing CERN Knowledge Transfer Group: MEDIPIX.
Leo Greiner TC_Int1 Sensor and Readout Status of the PIXEL Detector.
Detectors for Light Sources Contribution to the eXtreme Data Workshop of Nicola Tartoni Diamond Light Source.
Development of a high-speed single photon pixellated detector for visible wavelengths Introduction A photon incident on the photocathode produces a photoelectron.
COMPET Electronics and Readout
Beam Tests of 3D Vertically Interconnected Prototypes Matthew Jones (Purdue University) Grzegorz Deptuch, Scott Holm, Ryan Rivera, Lorenzo Uplegger (FNAL)
MX-10: Pixel Particle Detector V.Viswanathan, S.Martinek, M.Honig, P.Hubner Dr.Vijayaragavan VISWANATHAN 27/10/2013 IEEE-NSS: New Detector.
Power Pulsing in Timepix3 X. Llopart CLIC Workshop, January
ERIK FRÖJDH – ESR 2 Mid Sweden University, CERN 14th October 20132nd ARDENT Workshop1.
1 07/10/07 Forward Vertex Detector Technical Design – Electronics DAQ Readout electronics split into two parts – Near the detector (ROC) – Compresses and.
High Speed Detectors at Diamond Nick Rees. A few words about HDF5 PSI and Dectris held a workshop in May 2012 which identified issues with HDF5: –HDF5.
Connecting EPICS with Easily Reconfigurable I/O Hardware EPICS Collaboration Meeting Fall 2011.
07-Jan-2010 Jornadas LIP 2010, Braga JC. Da SILVA Electronics systems for the ClearPEM-Sonic scanner José C. DA SILVA, LIP-Lisbon Tagus LIP Group * *J.C.Silva,
BTeV Hybrid Pixels David Christian Fermilab July 10, 2006.
P. Aspell CERN April 2011 CMS MPGD Upgrade …. Electronics 2 1.
Sensor testing and validation plans for Phase-1 and Ultimate IPHC_HFT 06/15/ LG1.
JRA-1 Meeting, Jan 25th 2007 A. Cotta Ramusino, INFN Ferrara 1 EUDRB: A VME-64x based DAQ card for MAPS sensors. STATUS REPORT.
11 October 2002Paul Dauncey - CDR Introduction1 CDR Introduction and Overview Paul Dauncey Imperial College London.
3D-ASICS for X-ray Science
The trigger-less TBit/s readout for the Mu3e experiment Dirk Wiedner On behalf of the Mu3e collaboration 24 Sep 20131Dirk Wiedner TWEPP2013.
Tracking at the Fermilab Test Beam Facility Matthew Jones, Lorenzo Uplegger April 29 th Infieri Workshop.
Status report Pillar-1: Technology. The “Helmholtz-Cube” Vertically Integrated Detector Technology Replace standard sensor with: 3D and edgeless sensors,
Edgeless semiconductor sensors for large-area pixel detectors Marten Bosma Annual meeting Nikhef December 12, 2011, Amsterdam.
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
Sumary of the LKr WG R. Fantechi 31/8/2012. SLM readout restart First goal – Test the same configuration as in 2010 (rack TS) – All old power supplies.
NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN.
The trigger-less readout for the Mu3e experiment Dirk Wiedner On behalf of the Mu3e collaboration 31 March 20161Dirk Wiedner.
29/05/09A. Salamon – TDAQ WG - CERN1 LKr calorimeter L0 trigger V. Bonaiuto, L. Cesaroni, A. Fucci, A. Salamon, G. Salina, F. Sargeni.
e- and h+ (with leakage current compensation up to ~2nA/pixel)
MADEIRA Valencia report V. Stankova, C. Lacasta, V. Linhart Ljubljana meeting February 2009.
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
H. Yousef, G. Crevatin,E. Gimenez,I. Horswell, D. Omar,N. Tartoni Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxon OX11 0DE Timepix3.
Digital Acquisition: State of the Art and future prospects
The Jülich Digital Readout System for PANDA Developments
Baby-Mind SiPM Front End Electronics
Tango Integration of Modern 2D Detectors
Development of LAMBDA: Large Area Medipix-Based Detector Array
KRB proposal (Read Board of Kyiv group)
Ewald Effinger, Bernd Dehning
Silicon Lab Bonn Physikalisches Institut Universität Bonn
Status of the Merlin Readout System
Eiger characterization results
TIMEPIX TESTBEAM TELESCOPE FOR AIDA
Angela Gligorova on behalf of the AEgIS and Medipix collaborations
Commodity Flash ADC-FPGA Based Electronics for an
PID meeting Mechanical implementation Electronics architecture
A new family of pixel detectors for high frame rate X-ray applications Roberto Dinapoli†, Anna Bergamaschi, Beat Henrich, Roland Horisberger, Ian Johnson,
The LHCb Front-end Electronics System Status and Future Development
Readout Systems Update
Red Pitaya with EPICS Andraz Pozar EPICS Collaboration Meeting
Presentation transcript:

NI Big Physics Summit CERN Medipix3 + National Instruments = Merlin A brief case study Ian Horswell Diamond Light Source Detector Group February 2016

Presentation Outline Introduction to the Medipix chips Readout Requirements Readout options Merlin System Excalibur From Single to Quad Timepix3 Summary and Looking Forward

The Medipix Collaboration Based in CERN, the Medipix3 Collaboration has about 22 International members. Has designed at least 3 Imaging chips and 2 Time resolving. The Medipix family are hybrid photon counting readout chips Images R Ballabriga & CERN

Characteristics of the Medipix Readout Chips

Medipix3 Readout Requirements Provide all low and high voltages power supplies. Enable chip to be equalised and run in all modes. Use all 8 output data lines for maximum speed. Achieve 100 frames/sec in 12bit mode continuously. Achieve 1000 frames/sec for >1 sec, burst mode. Provide test and diagnostic facilities to test the chip. User Interface (Graphical?)

+ + OR Medipix3 Readout Options LV Power Supplies HV Bias Supply Services (ADC,DAC) Enclosures User Interface + + OR Ni FlexRIO

Merlin Developed as a precursor / development tool for EXCALIBUR system Versatile, high speed readout system for Medipix3 Seems to have significant value in its own right

Excalibur 48 Medipix 3 chips in 3 modules of 8 X 2. One of the largest monolithic silicon sensors ever made. 6 Virtex 5 FPGA readout cards. In operation on Beamline I13

Merlin - From Single to Quad Same readout performance required but from 4 chips. Move from PXI chassis to PXIe. Move from NI-7952R to NI-7962R, bigger FPGA and more memory. New FlexRIO Adapter card, extra facilities and cables. Images courtesy of R Goldbrough Quantum Detectors

Merlin Quad Software not simply scaled, too many variables and too much data. New structures and techniques required :- DVRs, Classes and objects, multiple free running loops passing data via queues. Command and data links via TCP/IP to EPICS, TANGO, MATLAB etc. New sensors, thicker silicon, CdTe, GaAs needed a new HV/LV power card (+/-1000Vdc) ADC & DAC for control and monitoring PXI prototype card + PCB controlled from LabVIEW

Timepix3 Characteristics Pixel Arrangement 256 X 256 Pixel Size 55µm X 55µm Technology 130nm CMOS – 8 metalization layers Acquisition Modes Time of Arrival (ToA) Time over Threshold (ToT) Energy Event counting Integral ToT Readout Modes Data Driven (zero suppressed) Frame based (zero suppressed) Dead time per pixel 475 ns (pulse measurement and packet transfer time) Minimum Timing resolution 1.56 ns Minimum detectable charge 500e- Output bandwidth 1 to 8 SLVDS lines @ 640Mbps (DDR)

Timepix3 One Masters student + Merlin system + Timepix chipboards + 6 months Adapter board modified LabVIEW FPGA code changed and VHDL added for critical areas Host LabVIEW modified to suit the Timepix chip. Demonstrator up and running, Masters Thesis accepted. Tests with Alpha source ToA ToT Fast TOA

Diamond Fill Pattern Maximum of 936 bunches, Hybrid Mode 686 bunches + 1 in gap

MEASURED BUNCH STRUCTURE Energy Measurement ToT

Summary and Future Work Quad Medipix3 Detector system, Merlin, implemented using the NI FlexRIO, commercially available via Quantum Detectors. Installed on 5 Diamond beamlines, used in the HiZPad project. Timepix3 demonstrator system produced, test bed for VHDL code To be used in Time Resolving system below. Proposals for:- 72 Medipix3 chip system arranged in a 100deg arc for XPDF measurements. 18 slot NI chassis, 12 FlexRIO cards and MXI bridge to server for processing and 10Gbps links. (Controller + FPGA card with 10Gbps transceiver?) 160 Timepix3 chip Large Area Time Resolving Detector, 10sGBytes/s

Thank you for listening! Acknowledgements: None of this work would have been possible without the support and help of members of the Medipix3 Collaboration and my colleagues in the Diamond Detector Group.