Summary of Results from and Plans for the Ongoing SLAC ESTB T-506 Irradiation Study FCAL Hardware Meeting December 2, 2015 Bruce Schumm UCSC/SCIPP.

Slides:



Advertisements
Similar presentations
Combined Measurement Results of dedicated RD50 Charge Multiplication Sensors Christopher Betancourt 2, Tom Barber 2, Gianluigi Casse 1, Paul Dervan 1,
Advertisements

IAP-PAI 25/05/20051 CMS Si Rad. Hardness Introduction Damage in Si Neutron tests => Beam => Irrad. Setup.
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Plot Approval Yat Long Chan (CUHK) Igor Mandic (Ljubljana) Charlie Young (SLAC)
ILC R&D at SCIPP: Progress Report De-scoped ($97.5K) Proposal Activities Radiation Hardness for BeamCal sensors (new; with SLAC) KPiX/Double Metal Performance.
E cm up to 1 TeV, de- pending on site chosen Design luminosity of 2x10 34 cm -2 s -1 Beam spot: 550x5.7 nm Crossings every 337 ns for about 1  s; repeats.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Planning for Electromagnetic Irradiation Studies of Silicon Strip Sensors at SLAC/SCIPP Viltaliy Fadeyev, Spencer Key *, Donish Khan *, Tom Markiewicz,
ILC-Oriented R&D I: Electromagnetic Radiation Damage Studies BeamCal instrument expected to receive up to 100 Mrad per year of electromagnetically-induced.
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
X-ray radiation damage of silicon strip detectors AGH University of Science and Technology Faculty of Physics and Applied Computer Science, Kraków, Poland.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
June 3rd, 2009Studies of Depletion Voltage Jessica Metcalfe University of New Mexico Capacitance Measurements and Depletion Voltage for Annealed Fz and.
Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses SLAC Testbeam Workshop August
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
FCAL-Oriented R&D I: Electromagnetic Radiation Damage Studies BeamCal instrument expected to receive up to 100 Mrad per year of electromagnetically-induced.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
S.Hou, Academia Sinica Taiwan. 2Outline Optical links for ATLAS Laser-driver  fiber  PIN-driver LHC modules in service Rad-hard requirement for LHC/SLHC.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Charge Collection Study of Heavily Irradiated Silicon Microstrip Detectors Chris Lucas (University of Bristol) Irena Dolenc Kittelmann, Michael Moll, Nicola.
The T506 Experiment: Electromagnetically-Induced Radiation Damage to Solid-State Sensors Test Facilities Users Workshop SLAC, September Bruce Schumm.
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Effects of Surrounding Materials on Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1, Robert A. Reed.
Effects of long term annealing in p-type strip detectors irradiated with neutrons to Φ eq =1·10 16 cm -2, investigated by Edge-TCT V. Cindro 1, G. Kramberger.
Initial Results from the SLAC ESTB T-506 Irradiation Study International Workshop on Future Linear Colliders University of Tokyo, November 2013 Bruce.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Plans for Radiation Damage Studies for Si Diode Sensors Subject to GRaD Doses International Linear Collider Workshop University of Texas at Arlington October.
Y.Unno, 4th Workshop on Advanced Silicon Radiation Detectors, Trento, Italy, Feb., Development of Radiation- tolerant p-type Silicon Microstrip.
Inversion Study on MCz-n and MCz-p silicon PAD detectors irradiated with 24 GeV/c protons Nicola Pacifico Excerpt from the MSc thesis Tutors: Prof. Mauro.
SPIE Astronomical Instrumentation June 26, 2008 Physics of reverse annealing in high- resistivity ACIS Chandra CCDs Catherine E. Grant (MIT) Bev LaMarr,
R.S. Orr 2009 TRIUMF Summer Institute
SiD FCal Effort SiD Workshop December Bruce Schumm UCSC/SCIPP.
Summary of Results from the SLAC ESTB T-506 Irradiation Study LCWS 2015 Whistler, BC, Canada November Bruce Schumm UCSC/SCIPP.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Production Readiness Review of L0/L1 sensors for DØ Run IIb R. Demina, August, 2003 Irradiation studies of L1 sensors for DØ 2b Regina Demina University.
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
The LHCb Vertex Locator Lars Eklund LHCb VELO Group of the LHCb Collaboration CERN (Geneva), EPFL (Lausanne), NIKHEF (Amsterdam), University of Glasgow,
Status of Forward Calorimetry R&D: Report from the FCAL Collaboration Bruce A. Schumm Santa Cruz Institute for Particle Physics University of California,
Albuquerque 1 Wolfgang Lohmann DESY On behalf of the FCAL collaboration Forward Region Instrumentation.
Radiation Damage Studies for Si Diode Sensors Subject to MRaD Doses Bruce Schum UC Santa Cruz July
Radiation Damage Studies for Si Diode Sensors Subject to MRaD Doses Bruce Schum UC Santa Cruz June
Charge Collection, Power, and Annealing Behaviour of Planar Silicon Detectors after Reactor Neutron, Pion and Proton Doses up to 1.6×10 16 n eq cm -2 A.
Summary of Liverpool CC(V) Measurements A. Affolder, P. Allport, H. Brown, G. Casse, V. Chmill, D. Forshaw, T. Huse, I. Tsurin, M. Wormold University of.
5 May 2006Paul Dauncey1 The ILC, CALICE and the ECAL Paul Dauncey Imperial College London.
The T506 Experiment: Electromagnetically-induced Radiation Damage to Solid-State Sensors Test Facilities Users Workshop SLAC, September Bruce Schumm.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Panja Luukka. Silicon Beam Telescope (SiBT) Group Since 2007 a collaboration of several CMS institutes has been operating a silicon micro-strip beam telescope.
Analysis of LumiCal data from the 2010 testbeam
Luminosity and Beamtuning Calorimeters in the very Forward Region
Solid-State Radiation Damage Studies
Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses SLAC Testbeam Workshop March
Non-Prompt Tracks with SiD BeamCal Radiation Damage Studies (Proposal)
BeamCal-Related SiD Work at SCIPP
Update from the UCSC/SLAC ESTB T-506 Irradiation Study
Radiation Damage Studies for Solid State Sensors Subject to Mrad Doses
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Radiation Damage Studies for Solid State Sensors Subject to MRaD Doses
Jin Huang Los Alamos National Lab
Progress on ILC Forward Calorimetry by the FCAL Collaboration
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Summary of Key Results from the SLAC ESTB
Testbeam Results for GaAs and Radiation-hard Si Sensors
CCE measurements with Epi-Si detectors
Radiation hard sensors for ILC forward calorimeter
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

Summary of Results from and Plans for the Ongoing SLAC ESTB T-506 Irradiation Study FCAL Hardware Meeting December 2, 2015 Bruce Schumm UCSC/SCIPP

2 T-506 Motivation BeamCal maximum dose ~100 MRad/yr BeamCal is sizable: ~2 m 2 of sensors. A number of ongoing studies with novel sensers: GaAs, Sapphire, SiC  Are these radiation tolerant?  Might mainstream Si sensors in fact be adequate?

3 Radiation Damage in Electromagnetic Showers Folk wisdom: Radiation damage proportional to non-ionizing component of energy loss in material (“NIEL” model) BeamCal sensors will be embedded in tungsten radiator Energy loss dominated by electromagnetic component but non-ionizing contribution may be dominated by hadronic processes

4 T-506 Idea Embed sample sensors in tungsten: “Pre-radiator” (followed by ~50 cm air gap) spreads shower a bit before photonic component is generated “Post-radiator” brings shower to maximum just before sensor “Backstop” absorbs remaining power immediately downstream of sensor  Realistic EM and hadronic doses in sensor, calibrated to EM dose

2 X 0 pre-radiator; introduces a little divergence in shower Not shown: 4 X 0 “post radiator” and 8 X 0 “backstop” Sensor sample

6 Irradiating the Sensors

LCLS and ESA Use pulsed magnets in the beam switchyard to send beam in ESA. Mauro Pivi SLAC, ESTB 2011 Workshop, Page 7

8 1 inch Sensor Pitch adapter, bonds Daughter Board Assembly

9 Dose Rates (Including 1 cm 2 Rastering) Mean fluence per incident e - Maximum dose rate (e.g GeV; 10 Hz; 150 pC per pulse): 30 Mrad per hour Confirmed with RADFET to within 10%

10 T506 Exposure History

11 Summer 2013: Initial Si Doses “P” = p-type “N” = n-type “F” = float zone “C” = Czochralski

12 Summer 2014: GaAs Doses GaAs pad sensors via Georgy Shelkov, JINR Dubna Irradiated with 5.7 and 21.0 Mrad doses of electromagnetically-induced showers Irradiation temperature 3 o C; samples held and measured at -15 o C

13 Summer 2015: SiC and Further Si Exposure SiC sensor array provided by Bohumir Zatko, Slovak Institute of Science Irradiated to ~100 Mrad dose Also, PF pad sensor irradiated to ~300 MRad

14 Assessing the Radiation Damage

15 Sensor + FE ASIC DAQ FPGA with Ethernet Charge Collection Apparatus Readout: 300 ns 2.3 MeV e - through sensor into scintillator

16 Channel-over- threshold profile Efficiency vs. threshold Median Collected Charge Charge Collection Measurement For strip sensors use multichannel readout

17 Daughter-board Low-noise amplifier circuit (~300 electrons) Charge Collection Measurement For pad sensors use single-channel readout

18 Mean Pulse Shape Measurement time Pulse-height distribution for 150V bias Median pulse height vs. bias Single-channel readout example for, e.g., N- type float-zone sensor Readout noise: ~300 electrons (plus system noise we are still addressing)

19 Results

20 Results: NF Sensor to 90 Mrad, Plus Annealing Study Limited beneficial annealing to 90 o C (reverse annealing above 100 o C?) Dose of 90 Mrad

21 Results: NC sensors Dose of 220 Mrad Incidental annealing ~15% charge loss at 300 ns shaping

22 GaAs 5.7 Mrad results 21 Mrad results are new

23 GaAs Charge Collection: 5.7 Mrad Exposure 15-20% charge loss at 300 ns shaping Seems to worsen with annealing Sensor detached at 30 o annealing step GaAs Dose of 5.7 Mrad

24 GaAs Dark Current (-10 0 C) O(100 nA/cm 2 ) after 6 MRad irradiation Not observed to improve with annealing

25 GaAs I-V after 21 Mrad Exposure (-10 C) At 600 V, about 0.7  A ( W) per cm 2 GaAs Dose of 21 Mrad GaAs IV Pre-anneal Post-anneal

26 GaAs Charge Collection after 21 Mrad Exposure ~60% charge loss at 300 ns shaping GaAs Dose of 21 Mrad No annealing

GaAs Charge Collection after 21 Mrad Exposure and Room Temperature Annealing 27 GaAs Dose of 21 Mrad Including 1 HR room- temperature annealing Pre-irradiation Post-irradiation, pre-anneal Post-irradiation, RT anneal

28 Compare to Direct Electron Radiation Results (no EM Shower) A bit better performance than direct result kGy Georgy Shelkov, JINR 1000 kGy = 100 Mrad Pre-anneal Post-anneal

29 P-Type Float-Zone Sensor New results for ~300 Mrad irradiation (about 3 years exposure)

30 NF I-V after 300 Mrad Exposure (-10 C) At 600 V, about 75  A (0.05 W) per cm 2 (sensor area ~ cm 2 )

31 NF Charge Collection after 300 Mrad At 600 V, about 30% charge collection loss

32 Next Run of T506

33 Looking Forward I 5-day x 24 hour run coming up in December Expected accumulation rate > 15 Mrad/hr Will have time for several 300+ Mrad runs Planning to expose N-type float-zone, and both P- and N-type Czochralski sensors Have not yet mastered system noise at level necessary to start looking into Sapphire Have not yet measured damage to 100 Mrad exposure of SiC Requested sample of LumiCal sensor material from Aaron and Yan; haven’t yet received it

34 Looking Forward II After this run, hope to have data in hand to form picture of what it would be like to run with silicon sensors Would be nice to also look at LumiCal sensor, but probably too late for this run. Need to assess 100 Mrad SiC sensor With some effort, should be able to get S/N ~ 2 for Sapphire. If so, we will want to expose that to hight doses Want to continue annealing the GaAs sensor to look for possible beneficial regime. If called for, will irradiated to higher doses.

35 Summary Continuing program of study of radiation damage in a realistic EM shower environment Have irradiated and several Si sensors to as much as 300 Mrad, and GaAs to 20 Mrad. Si sensors show fair charge collection after ~3 years irradiation; of order 0.05W/cm 2 to bias GaAs charge loss significant at 6 Mrad and substantial at 21 Mrad. Significant loss from mild annealing. Explore further annealing… SiC sensor irradiated to 100 Mrad; awaiting I-V and CCE study System noise still a bit high for Sapphire

36 BACKUP

37 Results: PF sensors Doses of 5 and 20 Mrad No annealing

38 Results: PC sensors Dose of 20 Mrad No annealing

39 Departure from NIEL (non-ionizing energy-loss) scaling observed for electron irradiation NIELe - Energy 2x MeV 5x MeV 1x MeV 2x MeV G.P. Summers et al., IEEE Trans Nucl Sci 40, 1372 (1993) Also: for ~50 MRad illumination of 900 MeV electrons, little loss of charge collection seen for wide variety of sensors [ S. Dittongo et al., NIM A 530, 110 (2004)] But what about the hadronic component of EM shower?

40 Results: NF sensor for low dose Doses of 5 and 20 Mrad No annealing

41 Hadronic Processes in EM Showers There seem to be three main processes for generating hadrons in EM showers (all induced by photons): Nuclear (“giant dipole”) resonances Resonance at MeV (~E critical ) Photoproduction Threshold seems to be about 200 MeV Nuclear Compton scattering Threshold at about 10 MeV;  resonance at 340 MeV  These are largely isotropic; must have most of hadronic component develop near sample