The ATLAS Beam Conditions Monitor Abstract The ATLAS Beam Conditions Monitor is being developed as a stand-alone device allowing to separate LHC collisions.

Slides:



Advertisements
Similar presentations
H. Pernegger, CERN, RD42 coll. Meeting May 2004 Diamond Beam Conditions Monitor for ATLAS (H. Pernegger, CERN)
Advertisements

TheBeam Conditions Monitor at ATLAS experiment Abstract The Beam Conditions Monitor at ATLAS experiment is being developed as a stand-alone device allowing.
The ATLAS Beam Diagnostics System
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
The ATLAS Beam Condition Monitor Commissioning Andrej Gorišek J. Stefan Institute, Ljubljana, Slovenia TWEPP Naxos, Greece September 2008 BCM-stations.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
1 Integrating Radiation Monitoring System for the ATLAS Detector at the Large Hadron Collider Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1 and.
ATLAS Radiation Monitor integrating monitor integrating monitor Igor Mandić, Vladimir Cindro, Andrej Gorišek, Gregor Kramberger, Marko Mikuž, Marko Zavrtanik.
IEEE08/NSS R. Kass N Radiation-Hard/High-Speed Data Transmission Using Optical Links W. Fernando, K.K. Gan, A. Law, H.P. Kagan, R.D. Kass, J. Moore,
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Online Radiation Dose Measurement System for ATLAS experiment I. Mandić a, representing ATLAS collaboration a Jožef Stefan Institute, Jamova 39, Ljubljana,
Study of leakage current and effective dopant concentration in irradiated epi-Si detectors I. Dolenc, V. Cindro, G. Kramberger, I. Mandić, M. Mikuž Jožef.
Edge-TCT and Alibava measurements with pion and neutron irradiated micro-strip detectors V. Cindro 1, G. Kramberger 1, I. Mandić 1, M. Mikuž 1,2, M. Milovanović.
Online Radiation Dose Measurement System for ATLAS experiment I. Mandić a, V. Cindro a, I. Dolenc a, A. Gorišek a, G. Kramberger a, M. Mikuž a,b, J. Hartert.
Status of Diamond Detectors and their (HEP) Application Rainer Wallny on behalf of CDF Diamond Group CMS BCM group + ATLAS BCM+Pixel groups RD42 Collaboration.
CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group.
The ATLAS Beam Conditions Monitor Marko Mikuž University of Ljubljana & Jožef Stefan Institute IEEE NSS’07 N31-7 Hawaii, October 31, 2007.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
 Bandwidth optimization  FFT analysis of average BCM MIP signal Confirmed in CERN SPS test beam, 200 MHz BWL on LeCroy LC564A: signal decrase by 1.5,
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
Effects of long term annealing in p-type strip detectors irradiated with neutrons to Φ eq =1·10 16 cm -2, investigated by Edge-TCT V. Cindro 1, G. Kramberger.
Marko Mikuž University of Ljubljana & J. Stefan Institute Diamond Pixel Modules for the High Luminosity ATLAS Inner Detector Upgrade ATLAS Tracker Upgrade.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
26 June 2006Imaging2006, Stockholm, Niels Tuning 1/18 Tracking with the LHCb Spectrometer Detector Performance and Track Reconstruction Niels Tuning (Outer.
K. Matsuoka (Kyoto Univ.) for T2K muon monitor group
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
E.Guschin (INR,Moscow) 3 May 2006Calorimeter commissioning meeting Status of PRS/SPD detector Cosmic test results Installation/tuning of monitoring system.
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
Annealing of CCE in HPK strip detectors irradiated with pions and neutrons Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko.
15/09/20111 ATLAS IBL sensor qualification Jens Weingarten for the ATLAS IBL Collaboration (2 nd Institute Of Physics, Georg-August-Universität Göttingen)
The LHCb Vertex Locator Lars Eklund LHCb VELO Group of the LHCb Collaboration CERN (Geneva), EPFL (Lausanne), NIKHEF (Amsterdam), University of Glasgow,
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Charge Collection, Power, and Annealing Behaviour of Planar Silicon Detectors after Reactor Neutron, Pion and Proton Doses up to 1.6×10 16 n eq cm -2 A.
Infrared Laser Test System Silicon Diode Testing 29 May 2007 Fadmar Osmić Contents: Setup modifications new amplifier (Agilent MSA-0886) new pulse generator.
TCT measurements with irradiated strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž.
FEE for Muon System (Range System) Status & Plans G.Alexeev on behalf of Dubna group Turin, 16 June, 2009.
The BTeV Pixel Detector and Trigger System Simon Kwan Fermilab P.O. Box 500, Batavia, IL 60510, USA BEACH2002, June 29, 2002 Vancouver, Canada.
QA Tests Tests for each sensor Tests for each strip Tests for structures Process stability tests Irradiation tests Bonding & Module assembly Si detectors1272.
RD05 Florence CVD Diamond Radiation Sensors For Application In Very High Radiation Environments 7 th International Conference on Large Scale Applications.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1,Gregor Kramberger 1, Marko.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1, Marko Zavrtanik 1,
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
RD42 Status Report W. Trischuk for the RD42 Collaboration LHCC Meeting – June 12, 2013 Development of CVD Diamond Tracking Detectors for Experiments at.
The ATLAS Beam Condition and Beam Loss Monitors Irena Dolenc (Jožef Stefan Institute, Ljubljana) on behalf of the ATLAS BCM group ICATPP th International.
Beam Conditions Monitor
Andrej Gorišek J. Stefan Institute, Ljubljana
Results achieved so far to improve the RPC rate capability
Upgrade of the scintillator testing station in Prague
Start Detector for pion experiments
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Position Sensitive TCT Measurements with 3D-stc detectors
Kröhnke, 14 November 2012 FCAL Collaboration Meeting Sergej Schuwalow
Simulated vertex precision
ATLAS BCM (Beam Condition Monitor) and
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Summary: Workshop on CMS Beam Conditions, Radiation Monitoring and Luminosity Systems Oliver Stein, May 2013, CERN.
Success is when preparation meets opportunity
(proxy for Harris Kagan) for the RD42 Collaboration
BESIII EMC electronics
Development of hybrid photomultiplier for Hyper-Kamiokande
CCE measurements with Epi-Si detectors
Status of CMS-PPS timing detectors
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

The ATLAS Beam Conditions Monitor Abstract The ATLAS Beam Conditions Monitor is being developed as a stand-alone device allowing to separate LHC collisions from background events induced either on beam gas or by beam accidents, for example scraping at the collimators upstream the spectrometer. This separation can be achieved by timing coincidences between two stations placed symmetric around the interaction point. The 25 ns repetition of collisions poses very stringent requirements on the timing resolution. The optimum separation between collision and background events is just 12.5 ns implying a distance of 3.8 m between the two stations. 3 ns wide pulses are required with 1 ns rise time and baseline restoration in 10 ns. Combined with the radiation field of n/cm 2 in 10 years of LHC operation only diamond detectors are considered suitable for this task. pCVD diamond pad detectors of 1 cm 2 and around 500 μm thickness were assembled with a two-stage RF current amplifier and tested in proton beam at MGH, Boston and SPS pion beam at CERN. To increase the S/N ratio two back-to-back diamonds were read out by a single amplifier and the detectors inclined to 45 degrees. Limiting the bandwidth at the readout to 200 MHz provided further improvement; S/N ratio of nearly 10:1 could be achieved with MIP's. Amplifiers of the two stages were irradiated with protons and neutrons to n/cm 2. Evaluating the irradiated electronics with silicon pad diodes, 20 % degradation in S/N ratio was observed. Ten detector modules are being assembled and tested at CERN for their final installation into the ATLAS pixel support structure in the beginning of M. Mikuž 1, V. Cindro 1, I. Dolenc 1, H. Kagan 5, G. Kramberger 1, H. Frais-Kölbl 4, A. Gorišek 2, E. Griesmayer 4, I. Mandić 1, H. Pernegger 2, W. Trischuk 3, P. Weilhammer 2, M. Zavrtanik 1 1 Univ. Ljubljana / Jožef Stefan Institute, Ljubljana, Slovenia, 2 CERN, Geneva, Switzerland, 3 University of Toronto, Toronto, Canada, 4 Fotec, Wiener Neustadt, Austria, 5 Ohio State University, Columbus, USA Motivation  Provide distinctive signature of beam anomalies in ATLAS such as  Beam scraping at TAS collimators  Beam gas interactions  Stand alone device providing information about genuine interactions  Monitoring of interactions at LHC start-up  Luminosity assessment Requirements  Fast signals  Rise-time ~ 1 ns  Width ~ 3ns  Base line restoration in ~ 10 ns to prevent pile-up  Single MIP sensitivity  S/N ~ 10 for MIP before irradiation  Installation close to beam pipe at large η  Radiation hardness up to 50 MRad and π/cm 2  No maintenance scenario – robust detector Working principle  Distinguish interactions from background via time of flight  With two symmetric stations at ±Δz/2  Interactions: in time  Background: out of time by Δt = Δz/c  At high luminosity expect hits for each bunch crossing (BX)  Interactions at Δt = 0, 25, 50 … ns  Optimally background at Δt = 12.5 ns ⇒ Δz = 3.8 m X 2 detector stations, symmetric in z TAS events: t = 0, 2z/c; Δt=2z/c Interactions: Δt = 0, 25, … ns Δ Sensors  pCVD diamond sensors chosen  Radiation hard – shown to work at > π/cm 2  Fast signals – high velocity and cut-off due to trapping  Small leakage current – no cooling required  Procurement in collaboration with CERN RD-42  Sensors produced and conditioned by Element Six Ltd.  Metallized with proprietary radiation hard process at OSU  Sensor properties  Size 10 mm x10 mm, active 8 mm x 8 mm (metallization)  Thickness ~500 μ m  Charge collection distance ~220 μm  Holds ~ 2 V/ μm, operating voltage 1000 V, current ~ 30 pA  Sensor assembly – two sensors back-to-back at 45 ° to increase signal 183cm 38 cm ATLAS 44 m Pixel BCM modules Realization  Two stations with four detector modules each  Mounted on pixel support structure at z = ±183.8 cm  Sensor at r ~ 55 mm, about 20 mm from beam pipe Sensor with Au test metallization Sensor in module box MIP Back-to-back diamonds at 45 ° Front-end electronics  Two stage Fotec HFK500 amplifier  1 st stage: 500 MHz Agilent MGA GaAs MMIC low noise amplifier (A = 22 dB, NF = 0.9 dB)  2 nd stage: Mini Circuits Gali-52 InGaP HBT broad-band micro- wave amplifier (A = 20 dB)  Amplifiers tested for radiation hardness  Up to /cm 2 reactor neutrons and protons from CERN PS  Agilent: ~ 20 % amplification loss observed with Si diodes, no noise increase  Gali-52: 0.5 dB amplification loss FE amplifier OK for BCM application Amplifier schematic 1 st 2 nd stage Amplifier in module box Si diode signal Si diode noise Gali-52 amplification Non-irradiated/irradiated Agilent FE comparison BCM modules  Fe amplifier and sensor in module box  RF design  Sensors mounted back to back on ceramics  Amplifiers ~10 cm from sensor to reduce radiation dose  Mounted on pixel support tube in a bracket at 45° η range of BCM compared to other luminosity monitors in ATLAS The total of 10 BCM module boxes ready to be equipped with sensors BCM module equipped with sensors BCM module box in prototype bracket BCM module tests  Beam test at MGH Boston  Proton beam 200 MeV and 125 MeV  Signal ≥ 2.3 MIPs  Single and back-to-back sensors at 0 and 45° Signal increase 0->45° by ~ √2 Signal increase in double-decker by 2, noise by 1.3  Beam test at CERN SPS  SPS H8 pion beam – MIPs signal with 16 m of cable: S/N (most probable) ~ 7.5:1 Timing: difference between two stations 2.7 ns FWHM Improved to 9.2:1 by implementing 200 MHz BWL on scope  Bench tests at CERN  30 MBq 90 Sr source; ~ MIPs signal  QA for BCM modules  Module stability tests Noise independent of HV Good reproducibility of signals Signal stable to 4 % during 24 h, longer tests running  NINO amplifier-discriminator tests  Differential timing amplifier-discriminator (1 ns peak, 25 ns jitter)  LVDS output with width proportional to time-over-threshold  Radiation tolerant design by CERN-MIC  Signal split 1:12 into two inputs to increase dynamic range Tests confirm suitability as BCM back-end chip Back-to-back Single diamond 0° 45° single double Beam-test set-up at MGH Boston Fotec FE (500 MHz) 200 MHz BWL S/N ~ 7.5:1 S/N ~ 9.2:1 Typical MIP pulse 30 MBq 90 Sr sourceBCM module box Scintillator & PMT Source QA set-up at CERN FE output NINO output Amplitude Pulse-width NINO time-over-threshold functionality NINO count-rate vs. threshold for noise / signal & noise ~30 MRad ~100 kRad ATLAS PIXEL ATLAS PP2 electronics cavern Signal processing schematics ~15 m ~100 m Signal Noise