Presentation is loading. Please wait.

Presentation is loading. Please wait.

Plato Consortium Kickoff Meeting, Paris 1 09-Nov-2010 Plato CCD and Front-End Electronics Dave Walton UCL/MSSL 01483.

Similar presentations


Presentation on theme: "Plato Consortium Kickoff Meeting, Paris 1 09-Nov-2010 Plato CCD and Front-End Electronics Dave Walton UCL/MSSL 01483."— Presentation transcript:

1 Plato Consortium Kickoff Meeting, Paris 1 09-Nov-2010 Plato CCD and Front-End Electronics Dave Walton UCL/MSSL dmw@mssl.ucl.ac.uk@mssl.ucl.ac.uk 01483 204190

2 Plato Consortium Kickoff Meeting, Paris 2 09-Nov-2010 Overview Two types of CCD/FEE Normal 32 telescopes Full-frame, no shutter Cadence = 25 s (22 s integration, 3 s readout) 2 ports per CCD, 4 Mpix/s/port Fast 2 telescopes Frame-transfer Cadence = 2.5 s (frame transfer 0.4 s) 2 ports per CCD, 4 Mpix/s/port

3 Plato Consortium Kickoff Meeting, Paris 3 09-Nov-2010 Focal plane coverage

4 Plato Consortium Kickoff Meeting, Paris 4 09-Nov-2010 CCD progress – package and connections Flexi length 120 mm. Trade-off between thermal isolation and bandwidth/interference

5 Plato Consortium Kickoff Meeting, Paris 5 09-Nov-2010 CCD Parameters 4510 x 4510 pixels per CCD 18 µm pixel 81.2 x 81.2 mm 2 per CCD Full well >= 900 ke- Thinned, back-illuminated 3-side buttable Variant: Frame-transfer for fast cameras Total CCDs to fly = 136. Area = 0.9 m 2 Largest CCD area ever flown (?) Gaia CCD at MSSL Plato CCD is x2.4 larger In area

6 Plato Consortium Kickoff Meeting, Paris 6 09-Nov-2010 Revised, smaller FEE enclosure Flexi connecting the two PCB panels CCD connectors

7 Plato Consortium Kickoff Meeting, Paris 7 09-Nov-2010 Normal telescope readout sequence 3 s22 s For normal telescope, unshuttered readout gives some image smear For fast telescope, frame transfer time gives some image smear These effects can be corrected if necessary

8 Plato Consortium Kickoff Meeting, Paris 8 09-Nov-2010 New 2 X 16 bit ADC proposal

9 Plato Consortium Kickoff Meeting, Paris 9 09-Nov-2010 Fast telecope differences Frame-transfer operation Pixel rate per port 4 Mpix/s, same as normal telescope But CCDs read out in parallel continuously, 2.5 s cadence (so no multiplexing in analogue electronics) High data rate requires local DPU

10 Plato Consortium Kickoff Meeting, Paris 10 09-Nov-2010 FIN


Download ppt "Plato Consortium Kickoff Meeting, Paris 1 09-Nov-2010 Plato CCD and Front-End Electronics Dave Walton UCL/MSSL 01483."