Cooling Test Results on fuzzy carbon substrate Setup in Lotima Room Used water/glycol mix (70/30 by wt) Neslab chiller to set temp Small pump to get the flow rate Flow-meter calibration to the mixture Hydrometer to check density of mix Filter, insulator, glove box(dry N2) SMT resistors as heaters 4 wire RTDs to readout temperature (5 points; water inlet and outlet line, fuzzy carbon surface-entry,notch, exit) Also monitor pressure drop, absolute pressure of inlet Haven’t used laser to monitor vibration
2
Problems Sensitive to humidity and ambient temperature (do it in vacuum vessel) Two of the RTDs’ need to be re-calibrated (temporary fix; need more RTDs) Lack of pumping power, flow rate just above 1.4 L/min (new pump) Inside glove box – hard to manoeuvre and fix things (new plexi-glass box) Fuzzy carbon very fragile – so far only populate 1 side (starting to populate the other side) Measure temperature only outside the coupling piece on the inlet and outlet of coolant line
3
Results Sharon, Steve, Tim et al with the setup and test Vacuum vessel – PAB; empty vessel pumped down to 1x10 -9 torr. Plan to put in the fuzzy carbon substrate soon to see how good a vacuum we can get A lot of results; take time to digest Here only show highlights of some results
4
Highlights Too good to be true! I had a hard time to believe the results because the differences in the RTD readings between HEAT OFF and ON are so small. HEAT ON- 10.2W (RTD 1-5 ) ; no coolant 21.66 | 34.78 35.07 34.89 | 21.83 HEAT ON; coolant ON and chiller at 0C 7.52 | 9.78 10.06 9.87 | 7.94 HEAT OFF; coolant ON and chiller at 0C 7.56 | 7.58 7.68 7.87 | 7.91
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.