Engineering Department ENEN Consequences and Possible Cause of Elevated Collimator Temperatures Collimation Working Group 02.11.2015 L. Mettler, F. Carra, A. Bertarelli, M. Garlasche 2 November 2015L. Mettler – EN-MME1
2
Engineering Department ENEN Consequences of elevated collimator temperatures Discussion of “anomalous” temperatures recorded Outlook 2 November 2015L. Mettler – EN-MME2
3
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME3 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations
4
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME4 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations Acceptable collimator temperature: up to 50 o C Based on homogeneous T in steady state Impairs the vacuum → T and vacuum probes to trigger interlock Outgassing rate, e.g. of ferrites, scales exponentially with temperature
5
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME5 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations Specification for flatness in operation: 100µm Ensures efficient beam cleaning Error in flatness comprises Mechanical tolerance (~40 µm) Self-weight (~30 µm) Temperature distribution (~30 µm)
6
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME6 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations E.g. TCTP
7
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME7 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations E.g. TCTP
8
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME8 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations E.g. TCSG
9
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME9 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations E.g. TCSG
10
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME10 Elevated Collimator Temperatures Outgassing Flatness of active surface (jaw) Plastic deformations Different CTEs and temperature gradients lead to thermal stress Irreversible deformation typically first on cooling pipes Should not impair the functioning of cooling Depends on design/materials, e.g. for tertiary collimator > 100 o C (based on simulations for quench test)
11
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME11 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
12
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME12 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1 beam intensity jaw water
13
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME13 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
14
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME14 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
15
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME15 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
16
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME16 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
17
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME17 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
18
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME18 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1 C-C AC150 St. Steel CuNi10Fe1Mn Glidcop
19
Engineering Department ENEN Collimator temperatures > 40 o C All fluctuations in water T synced → water seems to flow Fluctuations in water T too large to discern evacuated heat Jaw and water T “uncoupled” → consistent with radiative cooling, τ ≈ 14 h Calibration offset in jaw temperatures Thermal loads estimated from heating curves (5.54 W per jaw in fill 4467) Since jaw T is homogeneous → no thermal morphing Cooling pipes wrongly connected 2 November 2015L. Mettler – EN-MME19 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
20
Engineering Department ENEN beam intensity jaw water 2 November 2015L. Mettler – EN-MME20 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
21
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME21 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
22
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME22 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
23
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME23 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
24
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME24 Anomalous Temperature Recordings TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1 R4550 Graphite St. Steel CuNi10Fe1Mn Glidcop
25
Engineering Department ENEN Collimator temperatures ≈ 60 o C Big gradient along jaw → FE model inaccurate; Outgassing not critical Water T appears to reflect heat evacuation (but T in unknown) Cooling performance within expected range (τ < 7 min) Is the quick cooling / gradient along jaw physical or does RF invalidate temperature probes? Keep an eye on vacuum and beam quality 2 November 2015L. Mettler – EN-MME25 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
26
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME26 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
27
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME27 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
28
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME28 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
29
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME29 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
30
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME30 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
31
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME31 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1
32
Engineering Department ENEN 2 November 2015L. Mettler – EN-MME32 Elevated Collimator Temperatures TCSP_A4R6_B1 TCLIA_4L8 TCSG_A5R3_B1 Modest collimator temperatures ≈ 30 o C Water ∆T large – may not be flowing or heated by other components Cooling is slow (τ > 1h) Check if water flowing