Download presentation
Presentation is loading. Please wait.
Published byHugh Hunt Modified over 8 years ago
1
PDC’06 - status of deployment and production Latchezar Betev TF meeting – April 27, 2006
2
2 PDC’06 – status of deployment and production Deployment Not discussing central services – all OK. From Monday – start of deployment of AliEn v.2-9 on all VO-boxes: standard VO-box setup, LCG 2.7.0 (site can still have LCG 2.6 production environment) LFC as local catalogue everywhere All done following Stefano’s instruction set Other sites (Opterons, Itaniums, US) deployed on a site- per-site basis Issues: Few patches to AliEn agents provided by Pablo (‘alien- installed update’ works) Few issues with site configuration (LFC access permissions, application software directory) – most of them solved by now, Patricia is very fast!
3
3 PDC’06 – status of deployment and production Deployment (2) General status: Ongoing, but very close to being finished for the key sites (list of sites later) Many new VO-boxes to be configured from scratch, subsequent releases and updates will be much faster Deployment procedures are quite polished by now Fast reaction of all experts (site and ALICE) sometimes the solution is found before the problem is reported
4
4 PDC’06 – status of deployment and production VO box support VO-specific software installation and VO-box management: Regional principle, few named experts handling the installation and support (alicesgm), good overlap and redundancy: CERN – Pablo Saiz (also AliEn expertise), Patricia Mendez Lorenzo, Latchezar Betev Italy – Stefano Bagnasco France – Artem Trunov, Jean-Michel Barbet (Subatech Nantes) Germany – Kilian Schwarz, Jan-Fiete Grosse Oetringhaus (Muenster) Russia – Mikalai Kutouski, Eygene Ryabinkin (RRC-KI) Romania – Claudiu Shiaua All others (NIKHEF, SARA, RAL, US) - Patricia Mendez Lorenzo, Latchezar Betev Site related problems are handled by the site admins
5
5 PDC’06 – status of deployment and production Site deployment status SiteLCG VO-box env.LFCFTSTo Do Italy:Bari,CNAF,Legnaro,Catania,Torino OK CNAFv.2-9 patches Legnaro – install v.2-9 Germany: GridKA, GSI, Muenster Update to v.2-7 Muenster OK (Opteron) GridKAWait for update and deploy France: CCIN2P3, Subatech, Clermont OK CCIN2 P3 v.2-9 patches, config Clermont - deploy Russia: ITEP, IHEP, RRC-KI, JINR, Troits, SPbSU, PNPI OK nonev.2-9 patches, PNPI - deploy USA: OSC, Houston, LLNL, LBNL noneOSC OK, Houston – deploy, LLNL, LBNL – no structure yet Other T2s: NIHAM, Kolkata, Poland, Czech Rep. OK nonePoland, Czech Rep – deploy Other T1s: NIKHEF, SARA, RAL OK SARA RAL v.2-9 patches
6
6 PDC’06 – status of deployment and production Storage Site storage is still not worked out completely: General installation of xrootd on site disk servers (see talk of Artem) Connectivity to storage – firewalled at CERN, solutions are discussed: As a consequence, applications cannot store/get data at CERN xrootd servers from/to outside centres FTS Regular transfer pattern CERN to T1s will be a constant part of the PDC06 ALICE FTS endpoints are now set at all ALICE T1s: The transferred files will be deleted at the destination – test of service, not (yet) a full-blown method of data replication
7
7 PDC’06 – status of deployment and production Conclusions and outlook Deployment of ALICE specific VO-box software is progressing well, deployment and support team in place Installation priorities worked out, inclusion of newly installed centres in production is transparent Very good interactions with site/LCG technical support, all problems are solved quickly, average in matter of hours, longest from today to tomorrow Production release of AliRoot imminent, physics data production will start immediately afterwards Question of storage access has to be resolved by then
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.