Download presentation
Presentation is loading. Please wait.
Published byCameron Banks Modified over 8 years ago
1
High Power Test @S1-Global ③ 1 STF Cavity Group Meeting @2010/10/18 Process Log Data Summary of LFD Result of LFD Summary of LFD RF response @Quench Kirk
2
Process Log of High Power Test ① 2 STF Cavity Group Meeting @2010/10/18 10/513:00Safety check for radiation in tunnel 13:05HV ON / TRG ON / RF ON 13:48Tuner set / RF conditioning of C1 starts 13:53X-ray emits @13.3MV/m 17:14RF Off by Arc #1 I/L @~217kW 17:32pulse width of flat-top : 100μs 1000μs 17:52RF Off by Q L I/L @~28MV/m (Quench!) 17:56RF Off by Q L I/L @~28MV/m (Quench!) 18:00F.B. ON 18:25RF Off by Vac. I/L 18:33LFD measurement by pulse shortening @27.2MV/m 18:59RF Off by Q L I/L @~28MV/m (Quench!) C1 : 27.2MV/m under condition of F.B. ON C1 Cavity
3
Process Log of High Power Test ② 3 STF Cavity Group Meeting @2010/10/18 10/613:26HV ON / TRG ON 13:35RF ON 14:30LFD measurement by FNAL starts Offset scanning / Delay scanning 18:30Piezo compensation by FNAL system starts F.B. Off DAQ system did not work well. Retry tomorrow! 18:57fin. C1 Cavity
4
Process Log of High Power Test ③ 4 STF Cavity Group Meeting @2010/10/18 10/713:00HV ON / TRG ON 13:07RF ON Keep without F.B. @25MV/m 13:30RF Off by unknown reason 14:30Piezo compensation by FNAL system starts 15:30Piezo compensation + F.B. ON by FNAL starts 15:50Waveguide connection from C1 to C4 cavity 16:05HV ON / TRG ON / RF ON 16:15RF Off by Q L I/L @~28MV/m (Quench!) 16:27RF Off by Q L I/L @~27MV/m (Quench!) 16:45Piezo compensation by FNAL starts @28MV/m 17:52Piezo compensation + F.B. ON by FNAL starts @27.4MV/m 18:55fin. C1 Cavity C4 Cavity
5
Process Log of High Power Test ④ 5 STF Cavity Group Meeting @2010/10/18 10/8 9:30Waveguide connection from C4 to C3 cavity 13:14HV ON / TRG ON / RF ON 13:25Piezo compensation by FNAL starts @18.9MV/m 14:15F.B. ON 14:20RF Off by Q L I/L @~19MV/m (Quench!) 14:42Piezo compensation + F.B. ON by FNAL starts @18.2MV/m 15:00Waveguide connection from C3 to C2 cavity 15:16HV ON / TRG ON / RF ON 15:20Piezo compensation by FNAL starts @22.6MV/m 17:12Piezo compensation + F.B. ON by FNAL starts @22.2MV/m 18:57fin. C3 Cavity C2 Cavity
6
Process Log of High Power Test ⑤ 6 STF Cavity Group Meeting @2010/10/18 10/1413:00HV ON / TRG ON / RF ON 14:16Quench, but any I/L did not work, He pressure increasing Q L I/L was not set! 14:33RF On 14:36Piezo compensation by FNAL starts 17:30Piezo compensation + F.B. ON by FNAL starts But, system did not work well 18:55fin. C1, 2 Cavities
7
Process Log of High Power Test ⑥ 7 STF Cavity Group Meeting @2010/10/18 10/15 9:30Waveguide connection from C1, 2 to C3, 4 cavity 13:20HV ON / TRG ON / RF ON C4 detuned for LFD measurement of C3 14:09F.B. ON 14:18Keep with F.B. ON @15MV/m 16:22LFD measurement by FNAL starts 17:42Change from C3 to C4 for LFD measurement C3 detuned, C4 tuned 17:57LFD measurement by FNAL starts 18:51fin. C1, 2 Cavities C3, 4 Cavities
8
Process Log of High Power Test ⑦ 8 STF Cavity Group Meeting @2010/10/18 10/13 9:35Waveguide connection to A2(MHI#6) and C1(AES#4) cavities 12:50Refrigerator ready 13:05Safety check for radiation in tunnel 13:10HV ON / TRG ON / RF ON 13:22Tuner set / Q L I/L worked (No I/L during tuner set) 13:44RF conditioning of A2 (MHI#6) starts / Vac. I/L worked (3x10 -5 Pa) 14:00RF Off by abnormal power supply of Klystron #2 Safety I/L by Door open in underground Safety check again 14:14HV ON / TRG ON / RF ON 14:32RF Off by Vac. I/L (Level set : 3x10 -5 Pa 2x10 -4 Pa) 15:18RF Off by Arc #2 I/L @~35MV/m 15:37RF Off by Arc #2 I/L @453kW 16:37RF Off by Arc #2 I/L @453kW 17:07RF Off by Vac. I/L @453kW 17:20LFD measurement starts by FNAL @30MV/m 18:05I/L Level set : 2x10 -4 Pa 3x10 -4 Pa 18:07RF Off by Q L I/L @40.0MV/m (Quench!) 18:29tuner set 18:49RF Off by Q L I/L @37.7MV/m (Quench!) A2 : 40.0MV/m under condition of Piezo ON (by FNAL) and F.B. Off A2 Cavity
9
Process Log of High Power Test ⑧ 9 STF Cavity Group Meeting @2010/10/18 10/1413:29HV ON / TRG ON / Disable Q L I/L 13:39RF ON / tuner set RF conditioning of A3 (MHI#7) starts with pulse width = 100μsec 13:52X-ray detected @13.4MV/m 13:57RF Off by Arc #3 I/L (~100kW) 14:02RF Off by Arc #3 I/L (~130kW) 14:03RF Off by Arc #3 I/L (~135kW) 14:45RF Off by Arc #3 I/L (~180kW) / Vac. I/L [3x10 -4 Pa 2x10 -4 Pa] 14:53RF Off by Arc #3 I/L (~212kW) 14:56RF Off by Arc #3 I/L (~224kW) 15:09RF Off by Arc #3 I/L (~282kW) 15:18RF Off by Arc #3 I/L (~330kW) 15:33Quench with 100μs @33.5MV/m / RF Off by Q L I/L 15:46Quench with 100μs @33.5MV/m / RF Off by Q L I/L 15:47pulse width of flat-top : 100μs 1000μs 16:24RF Off by Arc #3 I/L (~300kW) 16:31Quench with 1000μs @31.3MV/m / RF Off by Q L I/L 16:52Quench with 1000μs @31.8MV/m / RF Off by Q L I/L A3 Cavity
10
Process Log of High Power Test ⑨ 10 STF Cavity Group Meeting @2010/10/18 10/1417:00F.B. ON 17:25RF Off by Q L I/L (Not Quench, due to noise) 17:28RF Off by Q L I/L (Not Quench, due to noise) 17:31RF Off by Q L I/L (Not Quench, due to noise) 17:40RF Off by Q L I/L (Not Quench, due to noise) [1.8x10 6 1.5x10 6 ] 17:56RF Off by Q L I/L @32MV/m 18:04RF Off by Q L I/L (Not Quench) [1.5x10 6 1.3x10 6 ] 18:14LFD measurement by pulse shortening @31.7MV/m Miss-data taking due to cPCI1, not cPCI2 18:42RF Off by Arc #2 I/L (~390kW) 18:452000 pulses stored under F.B. ON @31.7MV/m 18:57fin. A3 : 31.7MV/m under condition of F.B. ON A3 Cavity
11
Process Log of High Power Test ⑩ 11 STF Cavity Group Meeting @2010/10/18 10/1513:35HV ON / RF ON / Q L I/L system renewal (but, not good) 14:20LFD measurement by FNAL starts (Offset scanning) 15:34Delay scanning starts @25MV/m 16:20LFD measurement by FNAL finishes 13:46RF Off by Vac. I/L 16:35F.B. ON 17:09RF Off by Arc #3 I/L 17:10RF Off by Q L I/L x 2 17:23LFD measurement by pulse shortening @31.7MV/m 18:0010,000 pulses data taking for A3 @31.7MV/m 18:51fin. A3 Cavity
12
STF Cavity Group Meeting @2010/10/18 10/19 9:20Waveguide connection from A3 to A1 cavity 13:00Safety check for radiation in tunnel 13:17HV ON / TRG ON / RF ON Abnormal tuner position on operation panel appears Network error for IOC 13:33A1(MHI#5) conditioning starts 13:51electron detected from end of beampipe @8.6MV/m 13:59RF Off by Q L I/L 14:04RF Off by Q L I/L 14:11RF off by Arc #1 14:13RF Off by Q L I/L @19.3MV/m 14:19RF Off by Arc #1 @120kW 14:21RF Off by Arc #1 @118kW 15:03RF Off by Arc #1 @~140kW 15:13RF Off by Arc #1 @154kW 15:35RF Off by Q L I/L 15:49RF Off by Arc #1 x 2 16:09RF Off by Arc #1 @215kW 16:18RF Off by Arc #1 16:25RF Off by Arc #1 16:40RF Off by Q L I/L 16:59RF Off by Q L I/L @29.0MV/m A1 Cavity Process Log of High Power Test ⑪ 12
13
STF Cavity Group Meeting @2010/10/18 10/1917:00pulse width of flat-top : 100μs 1000μs 17:05Q L I/L : 0.8 x 10 6 1.3 x 10 6 17:30RF Off by Q L I/L (Quench) @27Mv/m 17:34RF Off by Q L I/L (Quench) @27Mv/m 17:36RF Off by Arc #1 F.B. ON RF Off by P f I/L 18:31LFD measurement by pulse shortening @28.0MV/m 18:54RF Off by Q L I/L (Quench) @28.5Mv/m 18:56fin. A1 Cavity Process Log of High Power Test ⑫ 13
14
Evaluation for LFD @S1-Global 14 STF Cavity Group Meeting @2010/10/18 Pulse-cut method 100パルスの平均値と R.M.S. から求める。 flat-top のみと全パルス幅での時間領域に分けて評価する。 微分方程式から求めた結果と比較する。 Brandt 氏の方法による結果と比較する。 Long time operation 2000パルスの結果から micro phonics の影響を評価する。 10,000パルスの結果を用いて評価する(一部)。 Q 0 測定中の長時間データから評価する(最適条件)。 Piezo の有り無しでの変化を評価する。 1空洞、4空洞、8空洞運転での変化を評価する。
15
Data Summary of LFD @S1-Global ① 15 STF Cavity Group Meeting @2010/10/18 CavityDateTypeGradientF.B.Piezo# of pulse C1 (AES#4)2010/10/5pulse-cut27.2ONOff100 2010/10/7FNAL25.6OffON100 FNAL27.0OffON100 FNAL27.1OffON2,000 FNAL27.0ON 100 27.0ONOff100 C2 (ACC#11)2010/9/29pulse-cut22.0ONOff100 2010/10/8FNAL22.6OffON (no iter.)2,000 FNAL22.2ONON (no iter.)2,000 C3 (ZANON#108)2010/9/30pulse-cut18.0ONOff100 2010/10/8FNAL18.9OffON2,000 FNAL18.2ON 2,000 2010/10/15long time15.0ONOff2,000 C4 (ZANON#109)2010/10/1pulse-cut28.5ONOff100 pulse-cut29.2ONOff100 FNAL28.0OffON100 FNAL27.4ON 2,000 25.0ONOff100
16
Data Summary of LFD @S1-Global ② 16 STF Cavity Group Meeting @2010/10/18 CavityDateTypeGradientF.B.Piezo# of pulse A1 (MHI#5)2010/10/19pulse-cut28.0ONOff100 A2 (MHI#6)2010/9/24pulse-cut31.5ONOff100 pulse-cut34.2ONOff100 A3 (MHI#7)2010/10/14long time31.7ONOff2,000 2010/10/15pulse-cut31.7ONOff100 long time31.7ONOff10,000 A4 (MHI#9)2010/10/20pulse-cutONOff100
17
STF Cavity Group Meeting @2010/10/18 Result of LFD for AES#4 @S1-Global 17 27.2MV/m (F.B. ON) 336Hz 708Hz
18
Result of LFD for ACC#11 @S1-Global STF Cavity Group Meeting @2010/10/18 18 Not analyzed yet 22.0MV/m (F.B. ON)
19
Result of LFD for Z#108 @S1-Global STF Cavity Group Meeting @2010/10/18 19 Not analyzed yet 18.0MV/m (F.B. ON)
20
STF Cavity Group Meeting @2010/10/18 Result of LFD for Z#109 @S1-Global 20 29.2MV/m (F.B. ON) 552Hz1003Hz
21
Result of LFD for MHI#5 @S1-Global STF Cavity Group Meeting @2010/10/18 21 Not measured yet
22
STF Cavity Group Meeting @2010/10/18 Result of LFD for MHI#6 @S1-Global 22 34.2MV/m (F.B. ON) 183Hz 710Hz 183Hz 710Hz
23
STF Cavity Group Meeting @2010/10/18 Result of LFD for MHI#7 @S1-Global 23 31.7MV/m (F.B. ON) 131Hz 558Hz
24
Result of LFD for MHI#9 @S1-Global STF Cavity Group Meeting @2010/10/18 24 Not measured yet
25
Summary of Lorentz Force Detuning 25 STF Cavity Group Meeting @2010/10/18 A1 MHI#5 A2 MHI#6 A3 MHI#7 A4 MHI#9 C1 AES#4 C2 ACC#11 C3 ZANON #108 C4 ZANON #109 Gradient [MV/m] ?34.2 (31.5) 31.7?27.222.018.029.2 △ f detuned (total) [Hz] ?710558?7081003 △ f detuned (only flat-top) [Hz] ?183131?336552 Q L (High Power) [x10 6 ] ?2.502.42?2.322.43 Q L (Low Power) [x10 6 ] 2.41 2.402.412.40 2.412.40 Average [pulses] 100
26
RF response of Quench for A2 @40MV/m STF Cavity Group Meeting @2010/10/18 26
27
RF response of Quench for A2 @40MV/m STF Cavity Group Meeting @2010/10/18 27
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.