1 OSHA Federal Standards October 1, 2014 – September 30, 2015

2 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. M OST F REQUENTLY C ITED S ERIOUS V IOLATIONS IN C ONSTRUCTION 2015 2 1926 Overall MFC F ALL P ROTECTION – R ESIDENTIAL C ONSTRUCTION P ORTABLE L ADDERS N OT E XTENDED 3 FEET A BOVE L ANDING F ALL P ROTECTION – U NPROTECTED S IDES & E DGES F ALL P ROTECTION – T RAINING E YE AND F ACE P ROTECTION H EAD P ROTECTION S CAFFOLDS – F ALL P ROTECTION A ERIAL LIFTS – F ALL P ROTECTION S AFE A CCESS F ALL P ROTECTION – R OOFING W ORK ON L OW - SLOPED R OOFS 29 CFR 1926 S UBPARTS

3 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. G ENERAL S AFETY & H EALTH [1926.20 –.35] 3 E MPLOYEE T RAINING P ROGRAMS P ERSONAL P ROTECTIVE E QUIPMENT – E MPLOYER R ESPONSIBILITY I NITIATE AND M AINTAIN A CCIDENT P REVENTION P ROGRAMS I NSPECTIONS BY A C OMPETENT P ERSON SUBPART C H OUSEKEEPING

4 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. O CCUPATIONAL H EALTH & E NVIRONMENTAL C ONTROLS [1926.50 –.66] 4 W ASHING F ACILITIES FOR H ARMFUL C ONTAMINANTS L EAD – B IOLOGICAL M ONITORING E MERGENCY E YEWASH /S HOWER L EAD – C HANGE A REAS P ROVIDED P RIOR TO E XPOSURE A SSESSMENT L EAD – P ROTECTIVE C LOTHING & E QUIPMENT P ROVIDED P RIOR TO E XPOSURE A SSESSMENT SUBPART D L EAD – D ETERMINING EXPOSURE AT OR ABOVE ACTION LEVELS

5 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. P ERSONAL P ROTECTIVE & L IFE S AVING E QUIPMENT [1926.95 –.107] 5 E YE AND F ACE P ROTECTION H EAD P ROTECTION PPE – P ROVIDED U SED & M AINTAINED SUBPART E F OOT P ROTECTION R EQUIRED E YE & F ACE P ROTECTION – ANSI R EQUIREMENTS

6 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. 2A F IRE E XTINGUISHER P ROVIDED PER 3000 SQFT OF B UILDING A REA E XTINGUISHERS WITH 50 FT OF 5 GALLONS OF FLAMMABLE LIQUIDS P ROVIDING F IRE E XTINGUISHER N OT R ATED L ESS T HAN 2A FOR E ACH F LOOR F IRE P ROTECTION & P REVENTION [1926.150 –.159] 6 SUBPART F P ORTABLE F IRE E XTINGUISHERS I NSPECTED P ERIODICALLY & M AINTAINED I NSPECTION & M AINTENANCE OF F IRE F IGHTING E QUIPMENT

7 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. S IGNS, S IGNALS & B ARRICADES [1926.200 –.203] 7 T RAFFIC S IGNS AT P OINTS OF H AZARD T RAFFIC C ONTROL S IGNS /D EVICES F LAGGERS - S IGNALING SUBPART G U SE OF C AUTION S IGNS V ISIBILITY OF S IGNS AND S YMBOLS

8 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. M ATERIALS S TORED TO P REVENT S LIDING F ALLING, OR C OLLAPSE M ATERIALS H ANDLING, S TORAGE, U SE & D ISPOSAL [1926.250 –.252] 8 G ENERAL R IGGING E QUIPMENT I DENTIFICATION E XTERIOR D ROP C HUTES R IGGING E QUIPMENT I NSPECTION & R EMOVAL FROM S ERVICE W ELDED A LLOY S TEEL C HAIN S LING I DENTIFICATION SUBPART H

9 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. T OOLS : H AND & P OWER [1926.300 –.307] 9 G UARDING OF R OTATING /M OVING P ARTS G UARDING OF C IRCULAR H AND - HELD R IPSAWS T OOLS D ESIGNED FOR G UARDS – G UARDS IN P LACE G UARDING OF P ORTABLE C IRCULAR S AWS W OODWORKING T OOLS – ANSI R EQUIREMENTS SUBPART I

10 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. W ELDING & C UTTING [1926.350 -.354] 10 S ECURING OF C YLINDERS W HILE IN U SE R EGULATORS AND G AUGES S HALL B E IN P ROPER W ORKING O RDER C YLINDERS S ECURED U PRIGHT O XYGEN C YLINDER S TORAGE U SING C ABLES N EEDING R EPAIR SUBPART J

11 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. E LECTRICAL [1926.400 –.449] 11 E QUIPMENT I NSTALLATION AND U SE U SE OF GFCI OR A SSURED G ROUNDING P ROGRAM G ROUNDING P ATH W ORN /F RAYED C ORDS AND C ABLES F LEXIBLE C ORD S TRAIN R ELIEF SUBPART K

12 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. S CAFFOLDS [1926.450 –.454] 12 F ULL P LANKING P ROTECTION BY PFAS OR G UARD R AIL SYSTEM F ALL P ROTECTION A ERIAL L IFTS – F ALL P ROTECTION S AFE A CCESS SUBPART L

13 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. F ALL P ROTECTION [1926.500 –.503] 13 R OOFING W ORK ON L OW - SLOPED R OOFS R OOFING W ORK ON S TEEP R OOFS R ESIDENTIAL C ONSTRUCTION U NPROTECTED S IDES & E DGES F ALL H AZARD T RAINING SUBPART M

14 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. H ELICOPTERS, H OISTS, E LEVATORS, AND C ONVEYORS [1926.550 –.556] 14 H OISTS & E LEVATORS – C OMPLYING WITH M ANUFACTURER ’ S R ECOMMENDATIONS H OISTS & E LEVATORS – M ATERIAL H OIST S HALL C ONFORM WITH ANSI A10.5-1969 H OISTS & E LEVATORS – E NCLOSURES FOR H OIST T OWERS O UTSIDE OF S TRUCTURE SUBPART N

15 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. M OTOR V EHICLES, M ECHANIZED E QUIPMENT, & M ARINE O PERATIONS [1926.600 –.606] 15 I NDUSTRIAL T RUCK O PERATOR T RAINING I NDUSTRIAL T RUCKS ANSI B56.1-1969 R EQUIREMENTS M ODIFICATIONS THAT A FFECT C APACITY R ATING S AFE R IDING S PACE ON I NDUSTRIAL T RUCKS S AFETY P LATFORM S ECURED TO C ARRIAGE OR F ORKS SUBPART O

16 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. E XCAVATIONS [1926.650 –.652] C OMPETENT P ERSON - I NSPECTION AND E MPLOYEE R EMOVAL C OMPETENT P ERSON - I NSPECTIONS P ROTECTION FROM F ALLING /R OLLING M ATERIALS AND E QUIPMENT S AFE E GRESS C AVE - IN P ROTECTION SUBPART P

17 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. C ONCRETE & M ASONRY C ONSTRUCTION [1926.700 –.706] 17 R EINFORCING S TEEL G UARDING S HORING EQUIPMENT SHALL BE INSPECTED PRIOR TO ERECTION M ASONRY WALL OVER 8 FEET SHALL BE BRACED S EMICIRCULAR M ASONRY S AW G UARDING L OCKOUT /T AGOUT OF BULK C EMENT S TORAGE F ACILITIES SUBPART Q

18 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. S TEEL E RECTION [1926.750 –.761] 18 U NSECURED D ECKING IN CDZ E XCEEDING 3,000 SQFT. P ROTECTION F ROM F ALL H AZARDS M ORE T HAN 2 S TORIES OR 30 FEET P ROTECTION FROM F ALL H AZARDS F ALL H AZARD T RAINING F ALL P ROTECTION FOR C ONNECTION SUBPART R

19 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. U NDERGROUND C ONSTRUCTION, C AISSONS, C OFFERDAMS, AND C OMPRESSED A IR [1926.800 –.804] 19 D ESIGNATED PERSON STATION ABOVE GROUND 5- PERSON RESCUE TEAMS FOR JOBSITES LESS THAN 25 EMPLOYEES C ONTROLLING ACCESS TO UNDERGROUND BY UNAUTHORIZED PERSONNEL I NSPECTION OF DRILLING AREA BEFORE DRILLING OPERATIONS STARTS E MPLOYEES INSTRUCTED ON RECOGNITION AND AVOIDANCE OF HAZARDS UNDERGROUND SUBPART S

20 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. D EMOLITION [1926.850 –.860] 20 R EMOVAL OF S TRUCTURAL OR L OAD - SUPPORTING M EMBERS S HORING AND B RACING OF W ALLS AND F LOORS E NGINEERING S URVEY P RIOR TO D EMOLITION O PERATIONS U TILITIES S HUT O FF OR C APPED B EFORE D EMOLITION O PERATIONS O PEN W ALLS P ROTECTED B Y A H EIGHT OF 42 INCHES SUBPART T

21 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. P OWER T RANSMISSION AND D ISTRIBUTION [1926.950 –.968] 21 I NSULATION ON THE ENERGIZED PART SUBPART V N O I NDUCED V OLTAGES S UPERVISION AND A NNUAL I NSPECTION

22 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. 22 ROPS ON E QUIPMENT M ANUFACTURED ON OR A FTER S EPT 1, 1972 SUBPART W R OLLOVER P ROTECTIVE S TRUCTURE ; O VERHEAD P ROTECTION [1926.1000 –.1003] 1000( B )

23 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. S TAIRWAYS AND L ADDERS [1926.1050 –.1060] 23 U SING T OP S TEP AS A S TEP S TAIRWAY OR L ADDER P ROVIDED AT B REAK IN E LEVATION ON 19 INCHES P ORTABLE L ADDER – 3 FEET A BOVE L ANDING S URFACE A PPROPRIATE U SE L ADDER & S TAIRWAY H AZARD T RAINING SUBPART X

24 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. T OXIC & H AZARDOUS S UBSTANCES [1926.1100 –.1152] 24 A SBESTOS – E XPOSURE M ONITORING C LASS I, II, AND III W ORK IN R EGULATED A REA A SBESTOS – E XPOSURE A SSESSMENT BY A C OMPETENT P ERSON A SBESTOS – I DENTIFY P RESENCE, L OCATION & Q UANTITY OF ACM/PACM A SBESTOS – T RAINING P ROGRAM SUBPART Z

25 N UMBER OF S ERIOUS V IOLATIONS – FY 2015 29 CFR 1926. C RANES AND D ERRICKS IN C ONSTRUCTION [1926.1400 –.1442] 25 M ONTHLY I NSPECTION OF E QUIPMENT M AINTAIN B ARRIERS A ROUND H AZARD A REA E QUIPMENT I NSPECTION E VERY 12 M ONTHS S IGN P ERSON Q UALIFICATIONS O PERATION P ROCEDURES OF E QUIPMENT SUBPART CC