Download presentation
Presentation is loading. Please wait.
Published byMelinda Mathews Modified over 9 years ago
1
M Vinod Kumar Tejas Networks Ltd
2
Example Requirements Possible solutions
3
= O |8| 8
4
Operator 1 L2 Network Operator 1 L2 Network Operator 2 L2 Leased Line Operator 2 L2 Leased Line C1 C2 Carrier Ethernet/ EoSDH Carrier Ethernet/ EoSDH Op#1 L2 Service Customer Op#1 L2 Service Customer 1.Op#1 wants p2p L2VPN from C1 to C2 2.Op#1 leases L2 service from Op#2 3.ENNI Protection issue 1.Op#1 wants p2p L2VPN from C1 to C2 2.Op#1 leases L2 service from Op#2 3.ENNI Protection issue ENNI Work Protect Rail-Tel
5
Operator 1 L2 Network Operator 1 L2 Network Operator 2 L2 Leased Line Operator 2 L2 Leased Line C1 C2 Carrier Ethernet/ EoSDH Carrier Ethernet/ EoSDH Op#1 L2 Service Customer Op#1 L2 Service Customer 1.Working-ENNI fails traffic switches to protection-ENNI Protection-ENNI could be defined over the 4 topologies mentioned 1.Working-ENNI fails traffic switches to protection-ENNI Protection-ENNI could be defined over the 4 topologies mentioned ENNI Work Protect Fault Notification
6
Operator 1 L2 Network Operator 1 L2 Network Operator 2 L2 Leased Line Operator 2 L2 Leased Line C1 C2 Carrier Ethernet/ EoSDH Carrier Ethernet/ EoSDH Op#1 L2 Service Customer Op#1 L2 Service Customer Fault within the operator cloud may lead to ENNI protection ENNI Work Protect Fault Notification
7
Operator 1 L2 Network Operator 1 L2 Network Operator 2 L2 Leased Line Operator 2 L2 Leased Line C1 C2 Carrier Ethernet/ EoSDH Carrier Ethernet/ EoSDH Op#1 L2 Service Customer Op#1 L2 Service Customer No change to the customer frames ENNI Work Protect Carrier Frames Customer Frames
8
1. If working-ENNI fails then traffic be switched to the protection-ENNI Protection-ENNI may share zero, one or two terminal bridges with working-ENNI Fault notification may be sent to one or both operators 2. Fault within the operator cloud may lead to traffic movement from working-ENNI to protection-ENNI Example: when the node bridging MTNL and working-ENNI fails Fault notification be sent towards ENNI or the peering operator 3. No change to the customer frames Provider identifiers like S-VLAN, B-VLAN, TESI-ID, etc. may change at the ENNI from provider to provider
9
1. Enhancing PBB-TE with Open-jaw Alarm Indication Signal (AIS) in CFM 2. SPB Load sharing using ECT at ENNI (works for specific topology ‘8’ of ENNI) 3. New idea if and only if we cannot enhance the existing technology
10
Request for bringing a new PAR
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.