Trade and transmission1 ECON 4925 Autumn 2007 Electricity Economics Lecture 7 Lecturer: Finn R. Førsund
2
Trade and transmission 2 Trade between Hydro and Thermal The cooperative social planning problem
3
Trade and transmission 3 The Lagrangian function Inserting the energy balances Export for one country is import for the other
4
Trade and transmission 4 The Kuhn – Tucker conditions
5
Trade and transmission 5 Combining the bathtub diagram and the thermal diagram for two periods θ2θ2 Period 1 Period 2 c'c' c'c' Import Export p 1 Th =p 1 H = p 2 Th =p 2 H = ImportExpor t Hydro Thermal A'A'A M'M' M B'B'B
6
Trade and transmission 6 p 1 Th =p 1 H = 1 Trade Hydro –Thermal with reservoir constraint Period 1 Period 2 c'c' c'c' Import θ2θ2 p 2 Th =p 2 H = 2 A B C D Import Export Hydro Thermal Export γ1γ1 A'A' D'D'
7
Trade and transmission 7 Transmission The model of Lord Kelvin from 1881 (Smith, 1961) A single production node connected with a single consumption node Assumptions Voltage at consumption node given No binding capacity limit on the line Generating node Consumption node Electricity flow
8
Trade and transmission 8 The physical laws of transmission Ohm’s law Symbols P L = loss in kW I = current in amps R = resistance on the line in ohms L = length of line A = area of cross section ρ = specific resistance of the metal
9
Trade and transmission 9 The physical laws of transmission, cont. Constancy of energy Symbols P i = power produced (kW) P L = loss on the line (kW) P o = power received (kW) Kirchhoff’s laws Current flow into a node must be equal to current flow out (energy cannot be lost) Voltage drops around any loop sum to zero (relevant for loop flow networks) Ohm’s and Kirchhoff’s laws Flows distribute within loops proportional to impedance on lines
10
Trade and transmission 10 The connection between voltage and current Definition for AC Symbols Po = power at consumption node in kW Vo = voltage at consumption node I = current in amps cosφ = power factor of the consumer’s load φ = lag between voltage and current variation in an alternating-current circuit
11
Trade and transmission 11 The transmission production function Inserting in the power balance Introducing the weight of the cable K = 2dLA, d= specific weight Renaming P o and P i, x and e, multiplying each term above with K
12
Trade and transmission 12 Substitution between capital and power input Ex ante MRS (marginal rate of substitution) The explicit ex ante production function Scale properties ex ante and ex post Ex ante: constant returns to scale Ex post (fixed capital): decreasing returns to scale