Optimization of waveguide geometry in the CLIC-G structures Hao Zha 13/08/2014
2
When eow increase: Geometry of CLIC-G cell Beam axis b c ac=eow*bc bc iw/2 w/2 ldw 45 o rdw Optimized for magnetic field -- c -- eow=ac/bc Optimized for wakefield damping -- iw: waveguide opening -- w: wavegude width Independed parameters: Note : In all the next slides, if you see “maximum magnetic field”, the eow should have been optimized!
3
safety distance Compact waveguides There is safety distance between cells and loads. Smaller waveguide has shorter safety distance
4
RF test model for dipole modes Like wakefield monitor, measure the S-matrix for 4 waveguide port. Reflection of each port may refer a dipole modes. Port 1 Port 2 Port 4 Port 3 Frequency of first dipole mode
5
Circuit model Cavity Waveguide 1:N’ N:1 Cavity : Transmission line with higher Z 0 Waveguide: Transmission line with lower Z 0 Junction: Impedance converter
6
Compared with Gdfidl Cells with different apertureCells with different waveguide width
7
Annoying frequency shift Test cube resonator + 2 waveguide Dimension: 20mm*20mm*12mm Q is almost exactly same Analytical frequency of TE 101 Mode But the frequency has a shift
8
Study on waveguide geometry Sweep on waveguide width and opening. Width↓, Q↓, H-field↓, Opening↓, Q↑, H-field↓, Width Opening
9
Optimum waveguide width Why smaller width have better damping effect: Impedance match Here is CLIC-G Different waveguide width for middle cell Optimum waveguide width for cells
10
Sweep on First cell Optimum width = 10.3mm
11
Optimum on width & opening Width↓, Q↓, H-field↓, Opening↓, Q↑, H-field↓, Width ↓ and Opening ↓, Q==, H-field↓↓ Contour line of width and opening : Optimum width = 9.9mm
12
Original cell/Optimized width/Optimized width & opening Original cellOptimized widthOptimized width & opening Max-E field (MV/m) 202.4 202.3202.2 Max-H field (KA/m) 4.020 3.983↓3.940↓↓ Max-Sc (MW/mm2) 4.112 4.105↓4.102↓↓ Vg (%c) 1.6611.684↑1.696↑↑ R/Q (Mohm/m) 1461514822↑14929↑↑ Q 55595618↑5655↑↑
13
Mid cell Optimum width = 10mm Optimum width = 9.7mm
14
Last cell Optimum width = 9.7mm Optimum width = 9.5mm
15
New design for CLIC-G CellsOptimized widthOptimized width & opening widthOpeningWidthopening First10.3mm8mm9.9mm7.98mm Middle10.0mm8mm9.8mm7.94mm Last9.7mm8mm9.7mm7.90mm Original cellOptimized widthOptimized width & opening
16
Tapered cells (26 regular cell+2matching cell) Original cell Input power = 63.1 MW Optimized width Input power = 62.4 MW Optimized width & opening Input power = 62.1 MW ↓1.3↓2.6
17
Wakefield results W(s=0.15m) [V/pC/m/mm] Original: 5~6 Optimized width: 1~3 Optimized width & opening: 1~3 Original cell Optimized width Optimized width & opening
18
Thank you