Download presentation
Presentation is loading. Please wait.
Published byBrianna Banks Modified over 8 years ago
1
1 Magnetic Field Modulus Estimation Using Whisper. Comparison with FGM LPCE/CNRS 12-13 February 2007 Alban Rochel, Edita Georgescu, Jonny Gloag, Pierrette Décréau, Jean-Louis Rauch, Jean-Gabriel Trotignon, Xavier Vallières
2
2 Outline B Extraction Algorithm Presentation Spectrogram Pre-Processing Fce Extraction Method Results on Synthetic Spectrograms Comparison With FGM data 2001 Data 2002 Data
3
3 Outline B Extraction Algorithm Presentation Spectrogram Pre-Processing Fce Extraction Method Results on Synthetic Spectrograms Comparison With FGM data 2001 Data 2002 Data
4
4 B Extraction Algorithm Presentation Extraction of the electron gyro- frequencies fce in plasmaspheric passes, knowing that: Fce varies smoothly Fce is the fundamental for a set of harmonics
5
5 B Extraction Algorithm Spectrogram Pre-Processing Linear interpolation of missing frequency bins (due to on- board compression) Dummy bins added to have a [0kHz, 80kHz] frequency range rather than [2kHz, 80kHz].
6
6 B Extraction Algorithm Spectrogram Pre-Processing Image processing to enhance the visibility of the resonances Per-spectrum conversion to dB Top-hat morphological transformation in the frequency dimension to remove the large-scale trends
7
7 B Extraction Algorithm f ce Extraction Method Ideas: Assuming the temporal variation of f ce is linear locally. Locally searching the spectrogram for sets of harmonics Technique inspired by the Radon method (image processing)
8
8 B Extraction Algorithm f ce Extraction Method We define a “comb” as a possible (linear) fundamental and its harmonics, defined by the ordinate of the fundamental at its origin and its slope. For each spectrum, a portion of the spectrogram is extracted (neighbourhood of the spectrum). Origin ordinate: 1.2 Slope: 0.1 Origin ordinate: 0.5 Slope: 0.2 This spectrum
9
9 B Extraction Algorithm f ce Extraction Method The spectrogram intensity is averaged on each comb in an {origin x slope} domain (including various normalizations). A weight is applied for each point, depending on its distance (in time) from the central spectrum: less sensitive to curvature. slope origin ordinate Low High
10
10 B Extraction Algorithm f ce Extraction Method A second, more accurate, pass is performed in a neighborhood of the (origin, slope) maximizing the previous pass. The final (origin, slope) point defines the fce value for the spectrum.
11
11 B Extraction Algorithm f ce Extraction Method Post-processing: Using FGM f ce as reference Keep the points that follow the FGM f ce variations (criteria based on the smoothness of f WHI / f FGM ) Estimation of uncertainty: A criterion based on statistical considerations gives the order i of the highest order significant harmonic. Whisper frequency resolution r : 163Hz Uncertainty u defined as
12
12 Outline B Extraction Algorithm Presentation Spectrogram Pre-Processing Fce Extraction Method Results on Synthetic Spectrograms Comparison With FGM data 2001 Data 2002 Data
13
13 Results on Synthetic Spectrograms Synthtic spectrograms generated randomly as the sum of two gaussians Generated B Corresponding f ce and harmonics Addition of noise and blur
14
14 Results on Synthetic Spectrograms Results on 400 synthetic spectrograms (600 spectra each) → Unbiased, accurate method Average error on ratio: 0.0005% Std Deviation on ratio: 0.3806 Average error on difference: 0.016nT Std Deviation on difference: 1.823nT
15
15 Outline B Extraction Algorithm Presentation Spectrogram Pre-Processing Fce Extraction Method Results on Synthetic Spectrograms Comparison With FGM data 2001 Data 2002 Data
16
16 Comparison With FGM Data 2001, C1
17
17 Comparison With FGM Data 2001, C2
18
18 Comparison with FGM Data WHI/FGM mean (x100) WHI/FGM std dev (x100) WHI-FGM mean (nT) WHI-FGM std dev (nT) 2001, C1100.22352.07791.0356.187 2001, C2100.11131.16520.4305.021 2001, C399.94311.93120.0225.395 2001, C4100.25311.27800.9456.875 2002, C1100.37571.36460.9793.015 2002, C2100.15240.69050.5102.296 2002, C3100.08210.58450.3071.973 2002, C4100.29590.61031.0392.190 33.000 to 70.000 values/year/spacecraft (most of the plasmaspheric passes) Files delivered to FGM and EDI in mid-january (AI-2)
19
19 Perspectives Meeting with EDI and FGM teams after the workshop Comparison with EDI data Possibility to deliver 2003 on a short term Automatic production, no validation required, but the plasmasphere passes have to be determined manually
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.