Status of GIF++ Adrian Fabich, Dorothea Pfeiffer, EN-MEF-LE EATM, 27th August 2013
2
Contents 2 Gamma Irradiation Facility GIF++ Users’ requirements Layout Technical infrastructure Operation Radiation protection Safety 27/08/2013A. Fabich, EN-MEF-LE
3
Requirements for Physics 3 Purpose: Verifying detector performance in strong gamma background Investigating detector ageing Main requirements Strong photon field (background) from a source Increased demands also in view of LHC upgrades Secondary beam (signal): primarily muons, low intensity Infrastructure adequate for gaseous detectors Irradiation area ~100 m2 Operated in autonomous mode users not permanently present Requirements summarized in http://edms.cern.ch/document/1280118http://edms.cern.ch/document/1280118 27/08/2013A. Fabich, EN-MEF-LE
4
The present GIF in the West Area 4 Present GIF installed in former West Area Since 2004 secondary (muon) beam de-commissioned Since then only of limited use for physics Limited photon yield (137Cs, 650 GBq installed in `90s) Limited space for increasing number of users GIF will be decommissioned with the new GIF++ being operational. 27/08/2013A. Fabich, EN-MEF-LE West Area
5
H6 beam line H2 beam line H4 beam line H8 beam line GIF++ GIF++ location in EHN1 (North Area) 527/08/2013A. Fabich, EN-MEF-LE West Area EHN 1
6
627/08/2013A. Fabich, EN-MEF-LE Maintain possibility for H2 extension Maintain minimum 2m wide corridor (central) EHN1 – PPE154
7
GIF++ layout (1) 727/08/2013A. Fabich, EN-MEF-LE dump secondary beam PPE (entrance) MAD PPG PPX (only emergency) dump gas mixing zone Preparation zone cable trays to control room Irradiation area
8
GIF++ layout (2) 827/08/2013A. Fabich, EN-MEF-LE secondary beam -field 2 -field 1 shielding preparation zone gas mixing zone shielding ±37° cut view at 2m height PPE PPG PPX
9
View from Saleve 27/08/2013A. Fabich, EN-MEF-LE9
10
View from Jura 27/08/2013A. Fabich, EN-MEF-LE10
11
Supply zone 11 Formerly called “gas mixing zone” Two floor layout For gas and electronic racks Each with a false floor (EHN1 standard) 27/08/2013A. Fabich, EN-MEF-LE
12
Large material access 27/08/2013A. Fabich, EN-MEF-LE12
13
Iraddiation field (1) 27/08/2013A. Fabich, EN-MEF-LE13
14
Iraddiation field (2) 27/08/2013A. Fabich, EN-MEF-LE14
15
General infrastructure 15 Electricity: 50 kW light (+emergency) Ethernet cabling, cable trays demineralised water NO cryogenics Beam equipment Beam instrumentation Gases Neutral and mixtures (containing flammable gases) 15 gas supplies from the gas hut (build. 909) 10 patch panels in bunker/preparation zone Each for 4 neutral and 4 hazardous gases Cooling and ventilation Optional Supply lines should mainly be installed in the raised floor. 27/08/2013A. Fabich, EN-MEF-LE Measurements: autumn 2012 – spring 2013 (courtesy: R. Guida)
16
Source Ground - Trigger Cable Trays False Floor: permanent supplies 1627/08/2013A. Fabich, EN-MEF-LE Dennis Haasler Same concept in preparation area 40 cm free height Reducing the source height to 2 meter
17
27/08/2013A. Fabich, EN-MEF-LE17 3000 mm
18
GIF++ control room HNA 487 is the best choice with regard to accessibility of the GIF++ facility 27/08/2013A. Fabich, EN-MEF-LE18 GIF++
19
Personnel and Material Access PPG, Roof: If opened, patrol lost PPE & Turnstile: Access rights of people checked, key released and people counted PPE2: Key that was taken at turnstile has to be used in key access mode (patrol not lost) MAD: access for material up to PC size 27/08/201319A. Fabich, EN-MEF-LE Personal Protection Exit Personal Protection Gate Personal Protection Entry PPE & Turnstile Pre Zone Small material access
20
Cable and pipe routing 20 27/08/2013 A. Fabich, EN-MEF-LE
21
Temperature/humidity 21 Users’ requirements: 20-24 °C, humidity 30-50%. Optional: small ventilation unit Not required for safety aspects 27/08/2013A. Fabich, EN-MEF-LE Measurements: autumn 2012 – spring 2013 (courtesy: R. Guida)
22
Photon yields to muon detectors 2227/08/2013A. Fabich, EN-MEF-LE roof chamber Average flux 1.0 e5 s^-1 cm^ -2 floor chamber Average flux 1.2 e3 s^-1 cm^ -2 Downstream beam trigger: average flux 1.8 e4 s^-1 cm^ -2 Upstream beam trigger: average flux 5.9 e4 s^-1 cm^ -2 fine tracker Average flux 5.1 e5 s^-1 cm^ -2 D. Pfeiffer
23
Trapezoid shaped collimator yz 2327/08/2013A. Fabich, EN-MEF-LE Point source Cylindrical source No difference between point and cylindrical source D. Pfeiffer
24
Safety responsibility for implementation 24 with SBA (together with CERN expert groups) Radiation shielding Flammable gas detection and ODH (in bunker) Fire detection Access system/personnel protection Interlock(s), also with irradiator Gas zone: ATEX conform (PH) 27/08/2013A. Fabich, EN-MEF-LE
25
GIF++ irradiation zone 25 The irradiation zone hosting the irradiator is a controlled area (PPE154). inside a supervised area (EHN1). No risk of activation due to low intensities of secondary beam Presence of high intensity photon source requires additional precautions due to the prompt radiation levels: Extended shielding Access system Entrance chicanes 27/08/2013A. Fabich, EN-MEF-LE
26
Risk analysis 26 Carried out with general safety, radiation protection, equipment owners and access system. Radiation simulation for conceptual layout available Defines required shielding Full scale radiation simulation by end summer 2013 Needs for maintenance Regular inspection of irradiator system by CERN-RP and vendor Operations Access Controls Standard procedure(s) of EHN1 apply. No additional implications by the presence of the photon source. Incidents Additional hazards Gases (non and flammable) Electricity Heavy handling Civil engineering (concrete walls up to 6.5 m high) Safety file is in preparation. 27/08/2013A. Fabich, EN-MEF-LE
27
Radiation levels 27 Keeping lateral exterior limit well below 3 Sv/h At least 80 cm concrete Accordingly adapted chicanes Roof (no stay area) shielding adjusted for < 15 Sv/h Final design based on these conceptual shielding studies 27/08/2013A. Fabich, EN-MEF-LE horizontal cut at source height ( 2m) 160 cm
28
Radiation shielding 28 Shielding blocks Double layer closing the block joints Roof gaps closed with dedicated iron beams Chicanes for entrances 27/08/2013A. Fabich, EN-MEF-LE -field 2 -field 1 Vertical cut view Top cut view 160 cm max. 3 Sv/h max. 15 Sv/h max. 3 Sv/h
29
Radiation protection 29 RP monitoring Inside the irradiation area Monitoring of the source operation Dedicated RP monitoring 2 redundant ionization chambers connected to RAMSES Veto to the source operation In the surrounding EHN1 area Monitoring by existing beam monitoring (EHN1 standard) Access system EHN1 standard Access safety elements compliant with SIL3 Single Access System (SAS) for counting persons in the area. 27/08/2013A. Fabich, EN-MEF-LE
30
Operational controls 30 Users’ interface: CESAR For personnel access and beam control Standard HW/SW integration into SBA controls environment Access controls Beam controls Safety elements Irradiator provided with its own console. Only link to SBA controls via veto line and status logging. 27/08/2013A. Fabich, EN-MEF-LE
31
Safety conditions for active irradiator 31 Exclude direct exposure to -source Source out of parking position only possible if GIF++ access chain is CLOSED AND (protecting in upstream zone) Upstream beam dump is IN-BEAM OR PPE144 is CLOSED (no access) AND (protecting in downstream zone) Downstream beam dump is IN-BEAM OR PPE164 is CLOSED (no access) AND (no alarms) No fire No power failure No emergency stop button Irradiator controls included in industrial delivery. Veto from CERN safety chain will force source into parking position. 27/08/2013A. Fabich, EN-MEF-LE upstream dump downstream dump
32
Next steps 32 Safety file to be completed until end 2013 Risk analysis Full scale radiation simulation based on final layout Construction starts in September 2013 Commissioning with beam in autumn 2014 Expecting irradiator delivery in September 2014 27/08/2013A. Fabich, EN-MEF-LE